    Catalog Number 58600-18 Hac h sc100 ™ Contr oller Installation Manual 2/04 3ed © Hach Company , 2003, 2004. All rights reser ved. Printed in the U .S.A. ds/dp ...

  • Hach sc100TM - page 2

    2 T ab le of Contents Section 1 Specif ic at io n s ................ ................ ................ ................... ................. ................ ................ ............. .............. 3 Section 2 General Information ............... ................. ................ ................... ................ ................ ......... ...

  • Hach sc100TM - page 3

    3 Section 1 Specifications Specifications are subject t o change without not ice. Component Description Microproce sso r-co nt ro lle d measuring unit with measured v alue displa y , temperature displa y , and menu-driven system Controller Operatin g T e mperature –20 to 60 °C (–4 to 140 °F); 95% relative humidity , non-condensing with sensor ...

  • Hach sc100TM - page 4

    4 Section 2 General Inf ormation 2.1 Safety Inf ormation Please read this entire manual bef ore unpac king, setting up , or operating this equipment. P a y attention to all danger and caution stateme nt s. F ailure to do so could result in serious injury to the operator or dam age to the equipment. T o ensure that the pr otection provided b y this ...

  • Hach sc100TM - page 5

    5 Section 3 Installation DA N G E R : Only qualified person nel should conduct the installa tion tasks described in this section of the man ual. Figure 3-1 Components of a Basic Syst em 1. Controller 6. Lock w asher , ¼-inch I.D . (4), Cat. No . 8H1336 2. Mounting foot f or panel mounting (2), Cat. No . 1000B4F3222 7. Flat washer , ¼-inch I.D . ( ...

  • Hach sc100TM - page 6

    6 Installation 3.1 Mechanical Installation Install in an environment that is protected f rom corrosive fluids. 3.1.1 Contr oller Dimension Illustrations Figure 3-2 Contr olle r Dimensions Figure 3-3 Controller Moun ting Dimensions sc100 144.0 mm (5.67 inches) 150.0 mm (5.91 inches) 144.0 mm (5.67 inches) 80.27 mm (3.16 inches) 144.02 mm (5.67 inche ...

  • Hach sc100TM - page 7

    Installation 7 Figure 3-4 P an el Mount Cut-out Dimensions Figure 3-5 Conduit Hole Dimensio ns 133 mm (5.25 inches) 144 mm (5.67 inches) (ref only) 135 mm (5.31 inches) 144 mm (5.67 inches) (ref only) 67.4 mm (2.65 inches) 72 mm (2.835 inches) (ref only) 66.67 mm (2.625 inches) 75 mm (2.955 inches) (ref only) 6.35 mm (0.25 inch) 15.24 mm (0.60 inch ...

  • Hach sc100TM - page 8

    8 Installation 3.1.2 Using the Optional Sun Shield The optional sun shield was designed t o increase the readabili ty of the displa y by screening it from direct su nlight. See Replacement P ar ts on page 21 fo r order ing information. Figure 3-6 Sun Shield Kit Components Figure 3-7 Mounting the Contr oller in the Sun Shield 1. Sun shield 5. Pipe m ...

  • Hach sc100TM - page 9

    Installation 9 3.1.3 Mounting the Contr o ller Attach the controller to a rail or wall or mount it in a pane l. Supplied mounting hardw are is shown in Figure 3- 8 , Figure 3-9 , and Figure 3-10 . Figure 3-8 V ertical or Horizont al Pipe Mounting the Contr oller Figure 3-9 W all Mounting the Controller 1. Controller 4. Flat washer , ¼-inch I.D . ( ...

  • Hach sc100TM - page 10

    10 Installation Figure 3-10 Pa nel Mounting the Controller T o remov e the sensor connectors bef or e inser ting the controller enclosure into the panel cut-out : 1. Disconnect the wires at ter minal bloc k J5, see Figure 3 -20 on page 18 . 2. Loosen and remo ve the n ut securing the sensor connector insi de the enclosure. Remov e the sensor con ne ...

  • Hach sc100TM - page 11

    Installation 11 3.2 Electrical Installation D ANGER The instrument mu st be installed by qu al ifi ed tec h ni cal per sonnel for adherence to all applicable electrical codes. High-v oltage wiring for t he controller is conducte d behind the high v oltage barrier in the controller enclosu re. The barr ier must remain in plac e unless a qualified in ...

  • Hach sc100TM - page 12

    12 Installation Figure 3-12 Using the Opt io nal Stra in Reli ef and Conduit Plug Figure 3-13 Pr oper Wire Preparation a nd Inser tion 3.2.3 Wiring f o r P owe r at the Contr oller The instrument can be wired f or line pow er by hard-wiring in conduit or b y wir ing to a po wer cord. Regard less of the type of wire u sed, the connectio ns are made ...

  • Hach sc100TM - page 13

    Installation 13 7. Reinstall the high-v oltage barrier and latch to secure . Figure 3-14 Wiring Connections T able 3-2 P ower Wiring Information Te r m i n a l Number T erminal Description Wire Color Code for Nor th America Wire Color Code f or Europe 1 Hot (L1) Black Bro wn 2 Neutral (N) White Blue 3 Protective Earth (PE) Green Green w/yellow tr a ...

  • Hach sc100TM - page 14

    14 Installation Figure 3-15 Local Disconnect f or Po wer Cord Figure 3-16 Local Disconnect f or Hard-wired Line P ower 1. P ower terminal 2. P ower cord str a in relief 1. P ower terminal 2. Conduit strain relief NC NC NC COM COM COM NO F1 F2 NO NO RELAY C RELAY B RELAY A J1 J2 J4 NETWORK INTERF ACE CARD J3 J5 J6 U5 U9 S1 1 2 NC NC NC COM COM COM N ...

  • Hach sc100TM - page 15

    Installation 15 3.3 Alarms and Rela ys The controller is equipped with thre e unpowered rela ys rated 10 0–230 V ac, 50/60 Hz, 5 amp re sist ive maximum. See the sens or manual f or rela y setup details. 3.3.1 Connecting the Rela ys The rela y connector accepts 18–12 A WG wire (as determined by load application). Wire gaug e less than 18 A WG i ...

  • Hach sc100TM - page 16

    16 Installation 3.3.2 Connecting the Analog Outputs T wo isolated an alo g o utput s ( 1 and 2) ar e pro vided, see Figure 3- 18 . Ea ch out put can be set to 0–20 or 4 –20 mA, and can be assigned to represen t the measured paramete r or secondary measurement such as temper at ure. Make conn ections with twiste d-pair shield ed wire and co nnec ...

  • Hach sc100TM - page 17

    Installation 17 3.4 Connecting/Wiring the Sensor Cable The sensor cab le is supplied with a ke yed quic k-connect fitting f or easy attachment to the controller, see Figure 3-19 . Retain the co nnector cap to seal the connector opening in case the se nsor must be remo v e d. Optional e xtension cabl es ma y be purchased to e xtend the sensor cab le ...

  • Hach sc100TM - page 18

    18 Installation Figure 3-20 Har d-wiring the sensor 1. Cut the connector fr om the sensor cable . 2. Reinstall the plug on the sen sor access opening to maintain the envir onmental rating. 3. Strip the insulation on the cab le back 1-inch. Strip ¼-inch of each individual wire end. 4. Wire as sh own in T ab le 3-4 . 5. P ass the cable th rough cond ...

  • Hach sc100TM - page 19

    Installation 19 Figure 3-21 Netw ork Card P osition in the Contr oller T able 3-5 Network Connections at T erminal Block J1 T erminal Number ModBUS RS485 2-wire ModBUS RS485 4-wire ModBUS RS232 1 ProfiBUS 1 D + RD + Rx A – 2 D – RD – — B1 + 3 — TD + Tx A2 – 4 — TD – — B2 + 5 Common Common Common Common 6 No connection No connectio ...

  • Hach sc100TM - page 20

    20 Section 4 Maintenance 4.1 Cleaning the Controller With the enclosure securely closed, wipe t he exterior with a damp cloth. 4.2 Fuse Replacement The instrument contains two mai ns fuses . F ailed fuses ar e an indication that an equipment prob lem could e xist. Problem resolut ion and fuse replace ment should be perf or med only b y qualified se ...

  • Hach sc100TM - page 21

    21 Section 5 Replacement P ar ts Replacement Items Item Cat. No. Controller ...... ................ ................ ................. ................... ................ ................ ................ ............. ............... 58600-00 Controller in stallation kit ......... ................ ................ .................... ........... ...

  • Hach sc100TM - page 22

    22 Section 6 Ho w to Order U .S.A. Customers By T elephone: 6:30 a.m. to 5: 0 0 p.m. MST Monda y through F riday (800) 227-HA CH (800-227-4224 ) By Fax: (970) 669-293 2 By Mail: Hach Company P .O . Box 389 Lov eland, Colorado 805 39-0389 U .S.A. Ordering inf ormation by e-mail: orders@hach.com Inf o rmation Required International Customers Hach mai ...

  • Hach sc100TM - page 23

    23 Section 7 Repair Service A uthorization mu st be obtaine d from Hach Compan y bef ore sending an y items f or repair . Please contact the Hach Ser vice Center serving your location. In the Unite d States: Hach Company Ames Ser vice 100 Da yton Av enue Ames, Iow a 50010 (800) 227-422 4 (U.S .A. only) F AX: (515) 232-3 835 In Canada: Hach Sales &a ...

  • Hach sc100TM - page 24

    24 Section 8 Limited W arranty Hach Compan y warrants its products to the original pur chaser against an y defects that are due to faulty material or w orkmanship for a period of *one y ear* from date of shipment un less otherwise noted in the pr oduct manual. The sc100 Contr oller is warranted for tw o years fr om the date of shipment. In the even ...

  • Hach sc100TM - page 25

    25 Section 7 Compliance Inf ormation Hach Co . cer tifies this instru ment w as tested thoroughly , inspected, and f ound to meet its pub lished specifications when it w as shipped from the f actory . The Model SC-100 has been tested and is cer tifie d as ind ica te d to the following instrumentation stan dards: Pr oduct Safety UL 61010A-1 ( ETL Li ...

  • Hach sc100TM - page 26

    26 Compliance Inf ormation Additional Emissions Sta nda rd/s include: EN 55011 (CISPR 11), Class “A” emission limits Canadian Interference-causing Equi pment Regulation, IECS-003, Class A Suppor ting test records by Hewlett P ac kar d, Fo r t Collins, Colorado Hardwa re T est Center (A2LA # 0905 -01) and certified compliance by Hach Compan y . ...

  • Hach sc100TM - page 27

    27 Inde x A Alarms ................... ................... ................ ................. .. 15 Analog Outputs ... ................ ................ ................... ...... 16 C Cleaning Controller ........... ................ .................... ............... 20 Compliance Information ........ ................ ................ ...... 25 ...

  • Hach sc100TM - page 28

    Visit http: //www .hach .com ...

Fabbricante Hach Categoria Universal Remote

I documenti che otteniamo dal fabbricante del dispositivoHach sc100TM possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Hach
- manuali per l’uso sc100TM
- schede prodotto Hach
- opuscoli
- o etichette energetiche Hach sc100TM
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Hach sc100TM.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Hach sc100TM, manuali di manutenzione, brevi manuali o manuali utente Hach sc100TM. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Hach sc100TM.

Manuali per l’uso simili

Manuale completo del dispositivo Hach sc100TM, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Hach sc100TM dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Hach sc100TM.

Il manuale per l’uso completo Hach, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Hach sc100TM - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Hach sc100TM, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Hach sc100TM che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Hach sc100TM - che ci dovrebbe aiutare nei primi passi durante l'uso Hach sc100TM
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Hach sc100TM
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Hach sc100TM in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Hach sc100TM?

Utilizza il modulo sottostante

Se non hai risolto il problema con Hach sc100TM con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Hach sc100TM è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)