    Model 5000/6000 Model 5000/6000 FLOW-THROUGH FURNACE HU M IDIFIER Warranty Maintenance Troubleshooting Guide ...

  • Air King AK5000 - page 2

    W ARRANTY The manufacturer guarantees the for the period of one year from the date of purchase, the product will be free of defects in workmanship and/or material. As well the manufacturer offers a life time warranty on the flow through humidifier body . During the warranty period, we will replace or repair any defective part at no charge if the pr ...

  • Air King AK5000 - page 3

    4. The inlet filter is located inside the black orifice fitting . Using a pointy object (i.e. nail), remove the inlet. 5. The filter should be fairly clean and free of depree, 6. Replace or clean the inlet filter if required. If punctured or damaged, replace before operating the humidifier . Remember this filter protects the orifice fitting and sol ...

  • Air King AK5000 - page 4

    14. Reinstall the solenoid valve onto the humidifier side, feed the flexible black water supply tube back through the humidifier side, reinstall the humidifier side (if removed) onto the humidifier body and secure in place, reconnect the water supply to the solenoid valve, replace the humidifier’s front cover and secure in place, turn back on the ...

  • Air King AK5000 - page 5

    5 Model 5000/6000 Flow Through Humidifiers Component Item Description P arts List/ Humidifier Model Component Number W arranty P eriod Recommended Maintenance Duct Mount Humidity Sensor 6000 29 1 year Replace as required. Humidisense Electronic Humidifier Control 5000/6000 Not Shown 1 year Replace as required. – PN 011109001 Solenoid V alve Assem ...

  • Air King AK5000 - page 6

    6 WARRANTY/MAINTENANCE/TROUBLE SHOOTING GUIDE 010912000 1 /per d r ain ins er t 3 2 3 * S pe c i fy b r and 2 8 2 6 2 7 2 5 2 4 1 3 1 8 22 21 20 19 1 6 1 7 1 5 1 4 8 11 12 10 9 6 7 5 4 0109 3 7 000 1 /per in l e t w at er f i l t er 10 - 3 2 p l asti c s c re w 1 / 4 " w at er t u b e b r ass c om pre ssi o n n u t n y l o n f err u l e b r as ...

  • Air King AK5000 - page 7

    7 Model 5000/6000 Flow Through Humidifiers 3 drain insert 1/p er 0 1 09 1 2000 1 5 f eet / u nit 3 f eet / u nit 1 0 f eet / u nit in l et w ater f i l ter 2 3 * S p e c i f y b rand 2 8 2 7 2 6 2 5 2 4 n y l o n f err u l e b rass c o m p ressi o n n u t b rass insert 1/ 4 " w ater t u b e 1 0 - 3 2 p l asti c s c re w 1 3 1 8 22 2 1 20 1 9 1 ...

  • Air King AK5000 - page 8

    TROUBLE SHOO TING GUIDE MODEL 5000 AND 6000 HUMIDIFIERS PROBLEM : NOT ENOUGH HUMIDITY POSSIBLE CAUSE : Humidistat set too low . REMEDY : T urn up the humidistat. POSSIBLE CAUSE : Humidifier has only been installed for a few days. REMEDY : If you have just installed the humidifier it can take anywhere from 3 to 4 weeks to build up the humidity level ...

  • Air King AK5000 - page 9

    REMEDY : • Adjust bypass damper to fully open position. • Ensure the bypass tube is fully stretched out tight. • F urnace filter is dirty and needs replacement. • Bypass tube and humidifier not installed parallel, use hard ducting – use hard ducting for any elbows – take the most direct route when ducting . • The bypass tube or humidi ...

  • Air King AK5000 - page 10

    • The bypass tube or humidifier is installed in front of air- conditioning coils or is blocked in some other way – move to another location and ensure maximum air flow . • The fan delay on your furnace is not set properly and the furnace fan is shutting off too early when the air is still hot. Y ou should discuss with a HV AC professional to ...

  • Air King AK5000 - page 11

    POSSIBLE CAUSE : The humidifier is not turning off when the furnace is turning off . REMEDY : See section above for solution. If the unit is running when the furnace is not in heating mode then very little water will be evaporated and most of the water will be going down the drain. POSSIBLE CAUSE : The unit is working properly and the furnace is su ...

  • Air King AK5000 - page 12

    MODEL 6000 HUMIDIFIERS ONL Y PROBLEM : THE DIGIT AL HUMIDIST A T KEEPS RESET TING TO THE DEFAUL T SET TINGS. POSSIBLE CAUSE : P ower source (transformer) is plugged into an outlet which is being shut off or turns off via a switch. REMEDY : Relocate the transformer to an outlet which cannot be turned off – if you have a renovated basement the outl ...

  • Air King AK5000 - page 13

    MODEL AK5000 AK5500 & AK7000 SUPPLEMENTAL INSTRUCTION SHEET WARNING: THIS UNIT IS INTENDED TO BE INSTALLED BY AN LICENCED HVAC PROFESSIONAL – FOR THIS UNIT TO OPERATE PROPERLY THE SUPPLIED 24 VOLT TRANSFORMER MUST BE INTERLOCKED WITH THE FURNACE HEATING CYCLE – THE 24 VOLT TRANSFORMER SHOULD BE ENERGIZED ONLY WHEN THE FURNACE IS IN HEATING ...

  • Air King AK5000 - page 14

    FEUILLE D’INSTRUCTION COMPLÉMENTAIRE, MODÈLES AK5000, AK5500 ET AK7000 MISE EN GARDE : CET APPAREIL EST CONÇU PO UR ÊTRE INSTALLÉ PAR UN PROFESSIONNEL CVC AUTORISÉ SOUS LICENCE – POUR QUE CET A PPAREIL FONCTIONNE CONVENABLEMENT, LE TRANSFORMATEUR DE 24 VOLTS FOURNI DOIT ÊTRE INTERVERROUILLÉ AVEC LE CYCLE DE CHAUFFAGE DE LA FOURNAISE - L ...

Fabbricante Air King Categoria Humidifier

I documenti che otteniamo dal fabbricante del dispositivoAir King AK5000 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Air King
- manuali per l’uso AK5000
- schede prodotto Air King
- opuscoli
- o etichette energetiche Air King AK5000
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Air King AK5000.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Air King AK5000, manuali di manutenzione, brevi manuali o manuali utente Air King AK5000. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Air King AK5000.

Manuali per l’uso simili

Manuale completo del dispositivo Air King AK5000, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Air King AK5000 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Air King AK5000.

Il manuale per l’uso completo Air King, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Air King AK5000 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Air King AK5000, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Air King AK5000 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Air King AK5000 - che ci dovrebbe aiutare nei primi passi durante l'uso Air King AK5000
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Air King AK5000
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Air King AK5000 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Air King AK5000?

Utilizza il modulo sottostante

Se non hai risolto il problema con Air King AK5000 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Air King AK5000 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)