    8-Port Managed Industrial Ethernet Switch ISW -800M User's Manual ...

  • Planet Technology ISW-800M - page 2

    T rademarks Copyright ○ c PLANET T echnology Corp. 2006. Contents subject to which revision without prior notice. PLANET is a registered trademark of PLANET T ec hnology Corp. All other trademarks belong to their respective owners. Disclaimer PLANET T echnology does not warrant that the hard w are will work properly in all environments and applic ...

  • Planet Technology ISW-800M - page 3

    T able of Content s 1. INTRODUCTION ................................................................................................................... 5 1.1 Packet Contents .............................................................................................................. 5 1.2 How to Use Thi s Manual ................................... ...

  • Planet Technology ISW-800M - page 4

    4.12 IP Confi guration ........................................................................................................... 35 4.13 SNTP Configuration .................................................................................................... 36 4.14 IP Security ....................................................................... ...

  • Planet Technology ISW-800M - page 5

    1. INTRODUCTION The 8-Port 10/100TX with redundant ring Web management industrial switch is a cost- effective solution and meets the high reliabilit y requirements deman ded by industrial ap plications. T he switch can be eas ily managed through the Web GUI. It also provides the redu ndant ring function that can prevent the net work connection fail ...

  • Planet Technology ISW-800M - page 6

    ▫ CSMA/CD Protocol ▫ RJ-45 Port support auto MDI/MDI-X function ▫ 2K MAC address table ▫ 1Mbit memory buffer ▫ 2.0Gbps back-plane ▫ Wide-range redunda nt power design ▫ S tore and forward switch architecture ▫ DIN rail and 3-way wall mount design Industrial Conformance ▫ 12~48V DC, redundant po wer with polarity reverse protect fu ...

  • Planet Technology ISW-800M - page 7

    MAC address 2K Memory Buffer 1Mbit Network Cable 10Base-T : 2-pair UTP/STP Cat 3, 4, 5 cable 100Base-TX: 2-pair UTP/STP Cat. 5 cable 10Base-T : EIA/TIA-568 100-ohm (100m) LED Per port: Link/Activity (Green), Full duplex/Collision (Y ellow) Per unit: Power (Green), Power 1 (Green), P ower 2 (Green), Fault ( Y ellow), Master (Green) Back-plane 1.6Gbp ...

  • Planet Technology ISW-800M - page 8

    128kbps, 256Kbps, 512Kbp s, 1MB, 2MB, 4MB, and 8MB. Ingress filter packet type combination rules are Broadcast/Multicast/Unknown Unicast packet, Broadcast/Multicast p a cket, Broadcast packet only and all of packet. The packet filter rate can be set follow as:1Mbps 、 2Mbps 、 4Mbps 、 8Mbps 、 16Mbps 、 32Mbps 、 64Mbp s. Port mirror Support ...

  • Planet Technology ISW-800M - page 9

    2. HARDWARE INSTALLATION This section describes the functiona lities of the S witch's components an d guides ho w to install it on the rack or mount to the wall. Basic knowledge of net working is assumed. Please read this chapter completely before continui ng. 2.1 Product Description The PLANET Management Industrial Ethernet Switch provides su ...

  • Planet Technology ISW-800M - page 10

    Figure 2-1 ISW -800M Front Pane l 2.1.3 LED Indications LED Statu s Meaning Green The switch unit is power on. Power Off The switch unit is no power input. Green Power on Power 1 Off No power inputs Green Power on Power 2 Off No power inputs Y ellow Power failure or UTP port failure or Fiber port failure Fault Off No Power failure or UTP port fa il ...

  • Planet Technology ISW-800M - page 11

    Off No device attached Y ello w The port is operating in full-duplex mode. Blinks Collision of Packets occurs in the port. FDX/COL (Port 7 & 8) Off The port in half-dup lex mode or no device attached 2.1.4 Reset Button The reset button provides use r a quick and easy way to restart and set the configuration back to default value. 。 Restart: p ...

  • Planet Technology ISW-800M - page 12

    OFF Disable port 6 Alarm 6 ON Enable port 6 Alarm. If the port’s link fails, the fault LED will light up. OFF Disable port 7 Alarm 7 ON Enable port 7 Alarm. If the port’s link fails, the fault LED will light up. OFF Disable port 8 Alarm 8 ON Enable port 8 Alarm. If the port’s link fails, the fault LED will light up. OFF Disable the ring maste ...

  • Planet Technology ISW-800M - page 13

    V - V + V - V + 1. Insert the positive and negative wires into t he V+ and V - connector on th e terminal block connector . 2. T o tighten the w ire-cl amp screws for preventing the DC wires to loose. Power Notice: The wire range of terminal block is from 12~ 24 AWG . 2.1.8 Wiring the Fault Alarm Cont act The fault alarm contact is in the middle of ...

  • Planet Technology ISW-800M - page 14

    Fault Alarm Contact 24V DC Buzzer 24V Battery The open circuit will form when the power failure or port link failure. The fault alarm device will send a warning signal t warn the user, ex: alarm sound or flash light. 2.2 Mounting Inst allation This section describes ho w to install the Ethernet Switch and make connections to it. Please read the fol ...

  • Planet Technology ISW-800M - page 15

    Step2: Lightly push the button of DI N-Rail into the track. Step3: Check the DIN-Rail is tightly on the track. Step4: T o remove the industri al switch fr om the track, reverse steps above. 2.2.2 W all Mount Plate Mounting T o install the switch on the wall, please follows the instructions described belo w . Step1: Remove the DIN-Rail from the indu ...

  • Planet Technology ISW-800M - page 16

    Step3: Use the screws to screw the wall mount plate on the industrial switch. Step4: Use the hook holes at the corners of the wall mount plate to han g the industrial s witch on the wall. Step5: T o remove the wall mount plate, reverse steps above. ...

  • Planet Technology ISW-800M - page 17

    3. NETWORK INSTALLATION 3.1 Hardware Inst allation In this paragraph, we will describe how to inst all the 8-Port 10/100TX with redundant ring Web management industrial switch and the installation poi nts for attention. 1. Unpacked the Industrial switch. 2. Check the DIN-Rail is screwed on the Industrial s witch. If the DIN-Rail is not screwed on t ...

  • Planet Technology ISW-800M - page 18

    3.3 Redundant Ring Application The industrial switch supports the r edundant ring pr otocol that can help your net work system to recovery from network connection failure within 300ms or less, and make your net work system more reliable. The redundant ring algorithm is lik e as spanning tree protoc ol (STP) algorithm but it has faste r recovery tim ...

  • Planet Technology ISW-800M - page 19

    3.4 Coulping Ring Application In the network, it may have more than one redunda nt ring group. By using the coupling ri ng function can connect each redund ant ring for the redu ndant backu p. It can ensure th e transmissions bet ween two ring groups will no failure. The following figure is a sample of coupling ring appli cation. ...

  • Planet Technology ISW-800M - page 20

    3.5 Dual Homing Application Dual Homing function is to prevent the connection l ose between redundant ring group and up per level/core switch. Assign two ports to be the Dual Homing ports that one is working port and one is backup port in the redundant ring gr oup. The backup port that has smaller MAC address value will be selected by switch automa ...

  • Planet Technology ISW-800M - page 21

    4. WEB MANAGEMENT This section introduces the confi guration and functions of the Web-Based management. The following configuration steps are based on the firmware version 1.00. 4.1 About W eb-based Management Inside the CPU board of the sw itch exists an embedded HTML w eb site re siding in flash memory . It of fers advanced management featur es a ...

  • Planet Technology ISW-800M - page 22

    The Web management interface 4.4 Port S t atus In Port status, you can view every port status t hat depended on user's setting and the negotiation result. 。 Port: the port number . 。 Ty p e : the speed mode, ex: 100T X = 100Mbps. 。 Link: "Down" is "No Link". "UP" is "Link". 。 St ate: display port ...

  • Planet Technology ISW-800M - page 23

    4.5 Single port information Y ou can click the port on the Panel figur e on the le ft side of web GUI. Then, the single port information window will pop up and dis play the port current status information. Port information interface 4.6 Port S t atistics The following information provides a vie w of the current port statistic information. Click but ...

  • Planet Technology ISW-800M - page 24

    to clean all counts. Port S tatistics Interface 4.7 Port Control Y ou can change the port status. 1. Select the port by scroll the Port column. 2. S tate: disable or ena ble control of his port. 3. Negotiation: you can set auto negotiation mode is Auto, N way (specify the speed/duplex on this port and enable auto-negotiation), or F orce. 4. S peed: ...

  • Planet Technology ISW-800M - page 25

    Port Control interface 4.8 Switch Settings Y ou can assign the s ystem name and location and view the system information. 。 System Name: assign the name of s witch. The maximum length is 64 bytes. 。 System Location: assign the switch physical location. The maximum length is 64 bytes. 。 System Desc ription: display the description of switch. R ...

  • Planet Technology ISW-800M - page 26

    Switch Settings interface [NOTE] Remember to execute the "Save Configur ation" ac tion, otherwise the ne w configuration will lose when the switch power off. 4.9 Port Mirroring The Port mirroring is a method for monitor traffic in switched networks. T raffic through ports can be monitored by one specific port . That is, traf fic goes in o ...

  • Planet Technology ISW-800M - page 27

    Port Mirroring intrerface 4.10 VLAN configuration A Virtual LAN (VLAN) is a logical network grouping that limits the broadcas t domain. It allows you to isolate network traffic so only members of the VLAN receive traffic from the same VLAN members. Basically , creating a VLAN from a switch is logica lly equiva lent of reconnecting a group of net wo ...

  • Planet Technology ISW-800M - page 28

    VLAN Configuration interface 4.10.1 Port-based VLAN Packets can go among only members of the same VL AN group. Note all unselected ports are treated as belonging to another single V LAN. If the port-based VLAN enabled, the VLAN-tagging is ignor ed. In order for an end station to send packets to dif ferent VL ANs, it itself has to be either capable ...

  • Planet Technology ISW-800M - page 29

    VLAN – Port-based Add interface 6. Y ou will see the VLAN gro up displays. 7. If the groups' list is more than one page, you can click to view other VLAN groups. 8. Use button to delete unwanted VLAN. 9. Use button to modify existing VLAN group. [NOTE] Remember to execute the "Save Configur ation" ac tion, otherwise the ne w config ...

  • Planet Technology ISW-800M - page 30

    802.1Q VLAN interface 4.10.2.1 Basic 1. Click A dd button. 2. Management VLAN ID: it is used for remote management security . Only the port of VLAN group ID is equal to the Management VLAN ID can remote management that include telnet, SNMP , and Web browse the switch. Fill the specific VLAN ID number in Management VLAN ID column and mark the check ...

  • Planet Technology ISW-800M - page 31

    802.1Q VLAN – Add interface 6. Click . Then you will see the page as follow . ...

  • Planet Technology ISW-800M - page 32

    7. T o set the outgoing frames are VLAN -T agged frames or untagged. Then click . 。 Ta g : outgoing frames with VLAN-T agged. 。 Unta g: outgoing frames without VLAN-T agged. 4.10.2.2 Port VID : Configure port VID settings 1. Port VLAN ID: enter the port VLAN ID. 2. Click . 3. T o reset back to default value, click button. 802.1q VLAN - Port VLA ...

  • Planet Technology ISW-800M - page 33

    user . Y ou can set up the mail server IP , mail account, and forwarded email account for receiv ing the event alert. 1. Email Alert: enable or dis able the email ale rt function. 2. SMTP Serv er IP Address: set up the mail server IP address. 3. Authentication: mark the check box to enable a nd configure the email ac count and password for authenti ...

  • Planet Technology ISW-800M - page 34

    alert to the dedicate SMTP server . ¾ Power status: when the device power status has chang ed, the system will send out the alert to the dedicate SMTP server . ¾ SMNP A uthentication Failure: when the SNMP authentication fa il, the system will send out the alert to the dedicate SMTP server . ¾ Redundant Ring topo logy change: when the redundant ...

  • Planet Technology ISW-800M - page 35

    Power Alarm interface 4.12 IP Configuration Power alarm function enables the Relay alarm action. Without enabling po wer alarm function, the Relay alarm action will not work even the Rela y alarm is set. Mark the check box and click button. ■ DHCP Client: Enable or Disable the DHCP client functi on. When DHCP client function is enabling, the indu ...

  • Planet Technology ISW-800M - page 36

    IP Configuration interface 4.13 SNTP Configuration Y ou can configure the SNT P (Simple Network T ime Protocol) settings. The SNTP allows you to synchronize switch clocks in the Internet. 1. SNTP Client: enable or disable SNTP function to get the time from the SNTP server . 2. UTC Timezone: set the switch location time zone. The following table lis ...

  • Planet Technology ISW-800M - page 37

    ALA - Alaskan S tandard -9 hours 3 am HA W - Hawaiian St andard -10 hours 2 am Nome, Alaska -1 1 hours 1 am CET - Central European FWT - French Winter MET - Middle European MEWT - Middle European Winter SWT - Swedish Winter +1 hour 1 pm EET - Eastern European, USSR Zone 1 +2 hours 2 pm BT - Baghdad, USSR Zone 2 +3 hours 3 pm ZP4 - USSR Zone 3 +4 ho ...

  • Planet Technology ISW-800M - page 38

    SNTP Configuration 4.14 IP Security IP security function allows you to assign 10 spec ific IP addresses that have permission to access the switch through the web bro wser for the securing switch management. 1. Enable the IP Security: mark the check box to enable the IP security function. 2. Security IP 1 ~ 10: you can assign up to 4 specific IP add ...

  • Planet Technology ISW-800M - page 39

    IP Security interface 4.15 RSTP Configuration The Rapid S panning Tree Protocol (RSTP) is an evolution of the Sp anning Tree Pr otocol and provides for faster spanning tree convergence after a topology ch ange. The system also supports STP and the system will auto detect the connected device that is running STP or RSTP protocol. 4.15.1 System Confi ...

  • Planet Technology ISW-800M - page 40

    Rapid S panning-Tree Protocol learning and listeni ng states to the forwarding state. Enter a value between 4 throug h 30. [NOTE] 1. Must follow the rule to configure the MAX Age, Hello T ime, and For ward Delay T ime. 2 x (Forward Delay Time value -1) > = Max A ge value >= 2 x (Hello Time value +1) 2. Remember to execute the "Save Confi ...

  • Planet Technology ISW-800M - page 41

    mathematic calculation. False is incl uding the STP mathematic calculation. 7. Click button. [NOTE] Remember to execute the "Save Configur ation" ac tion, otherwise the ne w configuration will lose when the switch power off. RSTP – Per Port Configuration interface 4.16 Redundant Ring Redundant ring provide a fast er redundant recovery t ...

  • Planet Technology ISW-800M - page 42

    The system also supports the coupling ring that can connect 2 or more redunda nt ring group for the redundant backup function an d dua l homing function that prevent co nnecti on lose bet ween redundant ring group and upper leve l/core switch. ■ Enable Redundant ring: to e nable the redu ndant ring function. Marking the check box to enable t he r ...

  • Planet Technology ISW-800M - page 43

    [NOTE] 1. When you enable the redund ant ring function , you must disable the RST P . The redundant ring function and RSTP function cann ot exist at the same time. 2. Remember to execute the "Save Configuration" action, oth erwise the new configuration will lose when the switch power off. 4.17 QoS Configuration Y ou can configure Qos sett ...

  • Planet Technology ISW-800M - page 44

    QoS Configuration interface 4.18 IGMP The Internet Group Management Protocol (IGMP) is an inte rna l protocol of the Inter net Protocol (IP) suite. IP manages multicast traf fic by using s witches, routers, and hosts that support IGMP . Enabling IGMP allows the ports to detect IGMP queries and report packets and manage IP multicast traffic through ...

  • Planet Technology ISW-800M - page 45

    IGMP Snooping interface 4.19 SNMP Configuration The SNMP is a Protocol that governs the transfe r of information between management and age nt. The switch supports SNMP V1. Y ou can define manag ement stations as trap manager s and to enter SNMP community strings. Y o u also can define a name, location, and contact person for t he switch. Fill in t ...

  • Planet Technology ISW-800M - page 46

    4.19.3 T rap Manager A trap manager is a management station that receives traps, the system alerts generated by the switch. If no trap manager is defined, no traps will issue. Creat e a trap manager b y entering the IP address of the station and a community string. 1. IP A ddress : fill in the trap device IP . 2. Community S trings: the trap device ...

  • Planet Technology ISW-800M - page 47

    Security Manager interface. 4.21 Configuration Backup In Configuration Backup, yo u can re store the backup configuratio n into the industrial switch. Also, you can backup the configuratio n to TFTP server . 4.21.1 TFTP Restore Configuration Y ou can restore flash ROM valu e from TFTP server , but you must put the backup ima ge in TFTP server , ind ...

  • Planet Technology ISW-800M - page 48

    TFTP Restore Configuration interrface 4.21.2 TFTP Backup Confi guration Y ou can save current flash RO M value from the industr ia l switch to the TFTP server , then go to the TFTP restore configuration page to restore the image value back to the ind ustrial switch. 1. TFTP Serv er IP Addre ss: fill in the TFTP server IP 2. Backup File Name: fill t ...

  • Planet Technology ISW-800M - page 49

    4.21.3 TFTP Update Firmware It provides the functions to allow a user to update th e switch firmware. Before updating, make sure you have your TFTP server ready and the firmware image is on the TFTP server . 1. TFTP Serv er IP Addre ss: fill in your TFTP server IP . 2. Firmware File Name: the name of firmware image. 3. Click . TPTP Update Firmware ...

  • Planet Technology ISW-800M - page 50

    Factory Default interface 4.23 Save Configuration Save the industrial switch configurati on to the flash memory . Power of f the industrial s witch without the saving, all changed configuration will lost. Click the button the save the config uration. Save Configuration interface ...

  • Planet Technology ISW-800M - page 51

    4.24 System Reboot Reboot the Switch in software reset. Click button to rebo ot the switch. System Reboot interface 4.25 Rate Control Y ou can set up ever y port's bandwidth rate and packet limitation type. ■ Limit Packet type: select the packet ty pe that want to filter . The pa cket types have all type packet, broadcast/multicast/unknown u ...

  • Planet Technology ISW-800M - page 52

    2. Qos and Rate control cannot be existed at the same. Rate Control interface 4.26 System Log Y ou can set up s ystem log events and view the system log events. 4.26.1 System Log Configuration Y ou can view the s ystem log events in here. Click button to get newest system log event and button to cle ar the log events. If log event list mo re that o ...

  • Planet Technology ISW-800M - page 53

    System Log Configuration 4.26.2 Event Configuration Y ou can select the s ystem log ev ents. When selected events occur , the system will send out the log information. Also, per port log events can be selected. ■ System event selection: 4 selections - Device col d start, Power status, SNMP Authentication Failure, and Redunda nt ring topology ch a ...

  • Planet Technology ISW-800M - page 54

    Event Configuration interface ...

  • Planet Technology ISW-800M - page 55

    5. TROUBLESHOOTING This section is intended to help you solv e the mo st common problems on the industrial Ethern et switch. 5.1 Incorrect connections The switch port can auto detect straight or crossove r cable when you li nk switch with other Ethernet device. For the RJ-45 connector shou ld use corre ct UTP or STP cable, 10/100Mbps port use 2-pa ...

  • Planet Technology ISW-800M - page 56

    IF the power indicator does turn on when the power cord is plugged in, you may have a probl em with power outlet, or power cord. However , if the Switch powers off after running for a while check for loose power connections, power losses or surges at powe r outlet. IF you still cannot resolve the prob lem, contact your local dealer for assistance. ...

  • Planet Technology ISW-800M - page 57

    6. APPENDIX 6.1 100BASE-TX/10BASE-T Pin Assignment s With 100BASE-TX/10BASE-T cable, pins 1 and 2 are used f or transmitting data, and pins 3 and 6 for receiving data. RJ-45 Pin Assignment s Pin Number Assignme nt 1 Tx+ 2 Tx- 3 Rx+ 6 Rx- Note: "+" and "-" signs repres ent the polarity of the wires that make up each wire pair . A ...

Fabbricante Planet Technology Categoria Network Card

I documenti che otteniamo dal fabbricante del dispositivoPlanet Technology ISW-800M possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Planet Technology
- manuali per l’uso ISW-800M
- schede prodotto Planet Technology
- opuscoli
- o etichette energetiche Planet Technology ISW-800M
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Planet Technology ISW-800M.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Planet Technology ISW-800M, manuali di manutenzione, brevi manuali o manuali utente Planet Technology ISW-800M. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Planet Technology ISW-800M.

Manuale completo del dispositivo Planet Technology ISW-800M, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Planet Technology ISW-800M dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Planet Technology ISW-800M.

Il manuale per l’uso completo Planet Technology, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Planet Technology ISW-800M - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Planet Technology ISW-800M, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Planet Technology ISW-800M che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Planet Technology ISW-800M - che ci dovrebbe aiutare nei primi passi durante l'uso Planet Technology ISW-800M
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Planet Technology ISW-800M
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Planet Technology ISW-800M in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Planet Technology ISW-800M?

Utilizza il modulo sottostante

Se non hai risolto il problema con Planet Technology ISW-800M con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Planet Technology ISW-800M è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)