Manuale per l’uso Quantum Data 700, 701

26 pagine 0.16 mb
Scarica

Vai alla pagina of 26

Summary
  • Quantum Data 700, 701 - page 1

    1 Model 700, 701 V i d e o T est Generators Quick Star t Guide Getting Star ted ........................................................................................................... 2 Computer Interfaces .................................................................................................... 3 User Interface ...................... ...

  • Quantum Data 700, 701 - page 2

    2 Model 700, 701 Quick S tart Guide Getting St arted Using AC Power Use only the AC adaptor provided with the generator to avoid operator injury and damage to the generator . Using Battery Power The generator uses six AA rechargeable nickel metal hydride (NiMH) batteries, which can be re- charged about 1000 times. Y ou may use alkaline batteries in ...

  • Quantum Data 700, 701 - page 3

    3 Computer Interfaces RS-232 9-Pin D-Sub Plug Pin Signal 1 No connection 2 Data in (Rx) 3 Data out (Tx) 4 DTR out 5 Ground 6 No connection 7 RTS out 8 CTS in External DC P ower / Battery Recharge Input Warning: Using an external power source other than the Quantum Data supplied AC po wer supply may injure the operator and damage the generator . Cen ...

  • Quantum Data 700, 701 - page 4

    4 Model 700, 701 Quick S tart Guide User Interface LCD Display The LCD window displays messages and menu options. Function Buttons _ Item _ 1 ______ Item _ 5* _ Item _ 2 ______ Item _ 6 _ Item _ 3 ______ Item _ 7 _ Item _ 3 ______ Item _ 8 Asterisk indicates active menu item. I tem 1 I tem 2 I tem 3 I tem 4 I tem 5 I tem 6 I tem 7 I tem 8 B uttons ...

  • Quantum Data 700, 701 - page 5

    5 Selecting Format s V iewing Formats by Signal T ype Press the Signal T ype button, and then select a signal type, to list formats based on the selected signal type. VESA Red, green, blue component color video per VESA standards. (DVI-to-VGA adaptor used for outputs.) NTSC/P AL Composite color baseband video signal (BNC connector) and Separate Lum ...

  • Quantum Data 700, 701 - page 6

    6 Model 700, 701 Quick S tart Guide Selecting Images Gating Outputs Press the Gating button to gate outputs, and to switch sync types. Note: Color gating works for all images except Ramp. *CutOff ________ _ GrayBar _ Window Regulate _ Focus Checker _ ColorBar ______ Dot_12 Selecting Images Press the Image button to select from list of available tes ...

  • Quantum Data 700, 701 - page 7

    7 Options Menu Press the Options button to set system-level options. Setting Power Save Preferences Pwr Save:On NTSC_CAL ___ Calibrate Clr _ Fmts _ _ ReloadFmts Power Save - Sets Power Saver pref erence Calibrate - Displays calibration menu for setting RG B analog video and sync amplitudes. Appears only if the generator has been configured to allow ...

  • Quantum Data 700, 701 - page 8

    8 Model 700, 701 Quick S tart Guide Calibrating Model 700 and 701 generators use programmable hardware to set the amplitude calibration factors for analog video outputs. These calibration factors are stored in Flash EPROM, and are not lost if the batteries are run down or removed. Quantum Data calibrates the analog video and sync output amplitudes ...

  • Quantum Data 700, 701 - page 9

    9 Calibrating Calibrating Outputs 1. Select Options > Calibrate > Reset to set the generator’s calibration factors to default nominal values. 2. Press Options > Calibrate > Full Scale. 3. Set the voltmeter’s scale factor to be able to measure a nominal 1000 millivolts DC. 4. Using a VGA-to-BNC cable, connect the generator’s red ou ...

  • Quantum Data 700, 701 - page 10

    10 Model 700, 701 Quick S tart Guide Calibrating Locking Calibration Settings The generator uses an internal hardware jumper to enable and disable changes to calibration settings. If the Options > Calibration option is available, the jumper is set to enable re-calibration. T o prevent users from changing calibration settings: 1. T urn the genera ...

  • Quantum Data 700, 701 - page 11

    11 _______ Reading _____ Monitor EDID _______ COMPLETE Details Show details of EDID after successful read back from displa y under test Complete indicates EDID data was read bac k correctly . Failed indicates unab le to read back v alid EDID data Learn Monitor If the generator is connected to a VESA DCC- compliant display , press the Learn Monitor ...

  • Quantum Data 700, 701 - page 12

    12 Model 700, 701 Quick S tart Guide T est Menu Press the T est button to select special test operating modes. Using T est Sequences Running T est Sequence Manually The generator includes a test sequence, which specifies a series of format and image combinations. T o run the test sequence, select T est > Sequence > Run, and then press the +/- ...

  • Quantum Data 700, 701 - page 13

    13 Running T est Sequence in Burn-In Mode Select T est > Burn-In > Run to automatically cycle through the test sequence. When the Burn-In mode is stopped, you can use the menu buttons to gate video color information, change sync types, and turn all signal outputs on and off. NOTE: The Burn-In mode disables the Power-Save feature, if enabled. ...

  • Quantum Data 700, 701 - page 14

    14 Model 700, 701 Quick S tart Guide Using Generator with CS-1 Probe The T est > CS1 Probe option uses the Quantum Data CS-1 color sensor to measure the chromaticity and luminance (brightness) of a display . The CS-1 probe connects to the generator’s serial port. Chromaticity is shown as x,y C.I.E. coordinates and the luminance (Y) can be show ...

  • Quantum Data 700, 701 - page 15

    15 S pecial T est s 2. Choose a DVI video format supported by the device. 3. Press T est > HDCP > S tart to output HDCP encrypted content. The display on the generator indicates if the test passed or failed. If the test passed, the currently selected pattern is displayed on the device under test. Noise is displayed if the HDCP authenti- catio ...

  • Quantum Data 700, 701 - page 16

    16 Model 700, 701 Quick S tart Guide About VGM Video Generator Manager (VGM) is a Windows-based application for creating and editing formats and test sequences. As many as 132 formats and one test sequence can be stored in the generator . VGM was originally created for use with Quantum Data 80x video generators. The 700-Series generators support on ...

  • Quantum Data 700, 701 - page 17

    17 Creating Video Format s Editing V ideo Formats Y ou can use VGM to create your own video formats. Y ou can start with a default format in the VGM format editor , or copy an existing format. T o create a video format: 1. Connect the generator with VGM, and then double-click the generator name. 2. Click the View Formats icon to list the available ...

  • Quantum Data 700, 701 - page 18

    18 Model 700, 701 Quick S tart Guide Modifying T est Sequence Editing the T est Sequence The generator has a default sequence, which you can edit in VGM. One sequence can be stored in the generator at the same time. T o modify the test sequence: 1. Connect the generator with VGM, and then double-click the generator name. 2. In the generator window ...

  • Quantum Data 700, 701 - page 19

    19 Flat_Wht/(R,G ,B) Description - Fills the screen with white, blue (B), green (G) or red (R). Application - Use to test chrominence. Grid Decription - White crosshatch on a black background. The lines form square boxes. A single pixel dot is located in the center of each crosshatch box. Application - Use the Grid pattern to test convergence. T o ...

  • Quantum Data 700, 701 - page 20

    20 Model 700, 701 Quick S tart Guide present across the entire screen, in a large portion of the screen, or localized in a very small area. Raster Description - Black display (nothing being displayed). Application - Useful for centering the raster on a CRT . Many monitor applications require that the displayed image or text fit completely within a ...

  • Quantum Data 700, 701 - page 21

    21 Regulate Description - The image has a pair of white outlined boxes which surround a blinking solid white box. Application - T ests for proper high volt age regulation. Checker Description - The image’s active video area is equally divided into a 6x6 checkerboard of black and white boxes. Application - The p attern is based on a proposed ANSI ...

  • Quantum Data 700, 701 - page 22

    22 Model 700, 701 Quick S tart Guide Ramp Description - This image provides an active video area starting from full black (+7.5 IRE for NTSC) at one edge of the screen to full white (+100 IRE) at or near the opposite end of the screen. Application - Useful for testing pixel anomolies and chrominance. PulseBar Description - The image looks like two ...

  • Quantum Data 700, 701 - page 23

    23 Updating Firmware The generator’s operating system firmware is stored in Flash EPROM, which you can update via the serial port. Firmware updates are available from http://www .quantumdata.com/support/downloads/. T o install a firmware update: 1. T urn off generator , and connect it to your PC using a null modem serial cable. 2. Hold down the u ...

  • Quantum Data 700, 701 - page 24

    24 Model 700, 701 Quick S tart Guide Specifications Video Formats Storage: 132 total Press Signal Type button to view signal types. Edit method: Windows-based VGM software T est Images (Patterns) Press Image button to list images. Hori z ontal Timing Frequency: 1 KHz to 250 KHz T otal pixels: 144 to 4096 Active range: 16 to 4096 pixels V e r tical ...

  • Quantum Data 700, 701 - page 25

    25 Service and Support Contacts T o contact T echnical Support, see http://www .quantumdata.com/contact/support.asp. For factory-authorized service centers, see http://www .quantumdata.com/contact/locations.asp. Model 700, 701 Quick Start Guide 68-00198-D (1-Oct-2004) Copyright © 2003 by Quantum Data, Inc. All rights reserved. The information cont ...

  • Quantum Data 700, 701 - page 26

    26 Model 700, 701 Quick S tart Guide ...

Fabbricante Quantum Data Categoria Portable Generator

I documenti che otteniamo dal fabbricante del dispositivoQuantum Data 700, 701 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Quantum Data
- manuali per l’uso 700, 701
- schede prodotto Quantum Data
- opuscoli
- o etichette energetiche Quantum Data 700, 701
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Quantum Data 700, 701.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Quantum Data 700, 701, manuali di manutenzione, brevi manuali o manuali utente Quantum Data 700, 701. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Quantum Data 700, 701.

Manuali per l’uso simili

Manuale completo del dispositivo Quantum Data 700, 701, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Quantum Data 700, 701 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Quantum Data 700, 701.

Il manuale per l’uso completo Quantum Data, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Quantum Data 700, 701 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Quantum Data 700, 701, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Quantum Data 700, 701 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Quantum Data 700, 701 - che ci dovrebbe aiutare nei primi passi durante l'uso Quantum Data 700, 701
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Quantum Data 700, 701
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Quantum Data 700, 701 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Quantum Data 700, 701?

Utilizza il modulo sottostante

Se non hai risolto il problema con Quantum Data 700, 701 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Quantum Data 700, 701 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)