Manuale per l’uso AGFA ANAPURNA M4F M4F

14 pagine 2.4 mb
Scarica

Vai alla pagina of 14

Summary
  • AGFA ANAPURNA M4F M4F - page 1

    Global Services North America Wilmington MA 01887 : ANAPURNA M4F AGFA UV INKJET PRINTER SITE PREPARATION GUIDE Distribution: Customer Sales Service Dealer 03/17/10 Revision 5.0 Questions? Contact 800-879-2432 and ask for an Anapurna Specialist 1 ...

  • AGFA ANAPURNA M4F M4F - page 2

    Global Services North America Wilmington MA 01887 Table of Contents Purpose: -------- ---------- ---------- ---------- -- ---------- ---------- -- ---------- ---------- -- ---------- ---------- ---------- -- -- ------ 3 Scope: -------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- -------- ---------- ---------- ------ ...

  • AGFA ANAPURNA M4F M4F - page 3

    Global Services North America Wilmington MA 01887 Purpose The purpose of this document is to assist the lo cal service represe n tative, who is responsible for configuring and installing the :Anapu rna. This docum ent will help to ensure the site will be re ady and the customer is informed of their re sp onsibilities. Pl ease go through all the inf ...

  • AGFA ANAPURNA M4F M4F - page 4

    Global Services North America Wilmington MA 01887 System Dimensions and Weights Dimensions Uncrated Dimensions Crated Weight: H = 63 Inches (1600 mm) H = 71 Inches (1800 mm) Crated: 3087 lbs (1400 Kg) W = 141 Inches (3570 mm) W = 153 Inches (3800 mm) Uncrated:2165 lbs (980 Kg) D = 57 Inches (1450 mm) D = 61 Inches (1550 mm) Dock & building acce ...

  • AGFA ANAPURNA M4F M4F - page 5

    Dock & building access Global Services North America Wilmington MA 01887 Foot Print and Working Area: Power and Air Connection Points: The power/air connection p oints are indi cated in the diagram above with the letters A , B , and C A – The power cable entry point lower c hassis – nea r the rear left leveling foot. B – Electrical termin ...

  • AGFA ANAPURNA M4F M4F - page 6

    Global Services North America Compressed Air Supply Wilmington MA 01887 Engine Air Connection: An adapter (shown below) is needed to connect the air hose from the air regulator to the printer. This should be purchased locally. Compressor: 3 - 5 HP , min 60 - 80 gallons or better tank. The compressor regulator should be set between 105 - 110 PSI for ...

  • AGFA ANAPURNA M4F M4F - page 7

    Global Services North America RIP Software and PC Platform Wilmington MA 01887 Wasatch RIP The Wasatch SoftRip is provided for raster image processing of images. Install the Wasatch SoftRIP on a PC, which meets the following platform specifications. Minimum Recommended System re quirements for Anapurna M4F ¾ CPU Type: Core 2 Duo, 3.06 GHz or faste ...

  • AGFA ANAPURNA M4F M4F - page 8

    Global Services North America AC Power Requirements Wilmington MA 01887 Power Requirements for the Anapurna M4F: The following electrical requirements must be provided to your electrician. • Single phase, 208 Y (Wye) power • 40 Amp, 60Hz, dedicated circuit with ground, no neutral • The electrician must provide the proper power cord and plug/r ...

  • AGFA ANAPURNA M4F M4F - page 9

    Global Services North America AC Power Requirements Wilmington MA 01887 The Buck/Boost Transformer The Anapurna M4F UV Printers requires power in the 230 – 240 VAC range for the UV lamps to properly cure the ink. At 208 Volts the customer will have curing problems and the lamps will fail prematurely. Buck/Boost Transformer and Specifications: • ...

  • AGFA ANAPURNA M4F M4F - page 10

    Global Services North America AC Power Requirements Wilmington MA 01887 Wiring Diagram to Boost Voltage (+32) for Single Phase Power: Input Voltage = 208 V Output Voltage = 236 V This diagram illustrates how to connect a 1.5 KVA, 16/32 Volt buck boost transformer. This wiring configuration boosts the line voltage from 208 to 236 Volts. Diagrams suc ...

  • AGFA ANAPURNA M4F M4F - page 11

    Global Services North America AC Power Requirements Wilmington MA 01887 Sample Buck/Boost Transformer: This photo is showing a sample Buck Boost Tran sforme r from Sola Hevi-Duty, it is a 1.5 KVA version, catalog # HS20F1.5A and it weights a p p roximately 38 pounds or 17.2 Kgs. Questions? Contact 800-879-2432 and ask for an Anapurna Specialist 11 ...

  • AGFA ANAPURNA M4F M4F - page 12

    Global Services North America Wilmington MA 01887 Site Readiness Check List Information to Check Yes No Lateral fork movement capability. Proper lifting rating? ( Pg.4) Forklift Length of forks should be 60 inches (152 .4cm) mi nimum Loading Dock If the customer does not have a loading dock, then the freight truck delivering the Anapurna will need ...

  • AGFA ANAPURNA M4F M4F - page 13

    Global Services North America Wilmington MA 01887 Customer Responsibilities The following information has been explaine d to the customer during the site preparation visit. The Customer and his operator(s) are responsible to be skilled in:  Knowledge of PC’s and Networking environment  Knowledge of Windows and Windows Applic ations  Know ...

  • AGFA ANAPURNA M4F M4F - page 14

    Global Services North America Wilmington MA 01887 General Information Environmental Requirements Room Operating Tempera ture: Range 68° F to 83° F (20 - 28° C) Ideal 72° F (22° C) (Room air temperature should not to exceed 126º F or 52 ºC) Humidity: Range 35% to 75% RH (non-condensing) Ideal 40% Room Air Exchange: 10 times per hour. The room ...

Fabbricante AGFA Categoria Printer

I documenti che otteniamo dal fabbricante del dispositivoAGFA ANAPURNA M4F M4F possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici AGFA
- manuali per l’uso ANAPURNA M4F M4F
- schede prodotto AGFA
- opuscoli
- o etichette energetiche AGFA ANAPURNA M4F M4F
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso AGFA ANAPURNA M4F M4F.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione AGFA ANAPURNA M4F M4F, manuali di manutenzione, brevi manuali o manuali utente AGFA ANAPURNA M4F M4F. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto AGFA ANAPURNA M4F M4F.

Manuali per l’uso simili

Manuale completo del dispositivo AGFA ANAPURNA M4F M4F, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare AGFA ANAPURNA M4F M4F dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti AGFA ANAPURNA M4F M4F.

Il manuale per l’uso completo AGFA, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale AGFA ANAPURNA M4F M4F - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice AGFA ANAPURNA M4F M4F, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per AGFA ANAPURNA M4F M4F che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo AGFA ANAPURNA M4F M4F - che ci dovrebbe aiutare nei primi passi durante l'uso AGFA ANAPURNA M4F M4F
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del AGFA ANAPURNA M4F M4F
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio AGFA ANAPURNA M4F M4F in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su AGFA ANAPURNA M4F M4F?

Utilizza il modulo sottostante

Se non hai risolto il problema con AGFA ANAPURNA M4F M4F con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con AGFA ANAPURNA M4F M4F è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (1)

Александр

Здравствуйте, нужна электронная схема для принтера agfa anapurna m