Manuale per l’uso York 48

32 pagine 0.82 mb
Scarica

Vai alla pagina of 32

Summary
  • York 48 - page 1

    254597-YTG-B-0507 FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE SINGLE P ACKAGE GA S/ELECTRIC UNITS AND SINGLE P ACKAGE AIR CONDITIONERS DH 036, 048 & 060 3, 4 & 5 NOMINAL TONS 12.2 THROUGH 13.2 SEER ® TECHNICAL GUIDE DESCRIPTION YORK Sunline Ultra ® units are convertible single package air conditioners with a common ...

  • York 48 - page 2

    254597-YTG-B-0507 2 Unitary Products Group T ABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 PRODUCT NOMENCLATURE . . . . . . . . . . . . . . . . . 3 FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 FACTORY-INSTALLED OPTIONS . . . . . . . . . . . . . . 5 FIELD-INSTALLED ACCESSORIES ...

  • York 48 - page 3

    254597-YTG-B-0507 Unitary Products Group 3 PRODUCT NOMENCLA TURE D H 048 N04 A 2 A AA 1 0 1 2 4 A D = A/C, Single Pkg., R-22 Product Category Airflow N = Belt Drive P = Belt Drive/Single Input Economizer R = Belt Drive/Motorized Damper A = Direct Drive B = Direct Drive/Single Input Economizer D = Direct Drive/Motorized Damper 1 = First Generation P ...

  • York 48 - page 4

    254597-YTG-B-0507 4 Unitary Products Group FEA TURES All models are available with a wide variety of factory- mounted options such as stainless steel heat exchangers, electric heaters, phase monito r , convenience outlet, dirty filter switch, disconnect switch, smo ke detectors, and coil guard to make them suitable for almost every application. All ...

  • York 48 - page 5

    254597-YTG-B-0507 Unitary Products Group 5 • BAS Controls - Y ork’s Sunlin e™ series unit s offer factory mounted BAS cont rols such as Simplicity ® INTELLI-Com- fort™, Novar , Honeywell, Johnson, and CPC. F ACTOR Y -INST ALLED OPTIONS • SINGLE INPUT ELECTR ONIC ENTHALPY ECONO- MIZERS - Includes a slide-in / plug-in damper assemb ly with ...

  • York 48 - page 6

    254597-YTG-B-0507 6 Unitary Products Group installed dirty filter indicator switch, an air-proving switch, an Outside Air Humidity sensor , a Return Air Humidity sensor , an Inside IAQ sensor , and an Outside Air IAQ sensor . Construction mode oper ation, 365-day real ti me clock with 7 day programming plus holiday scheduling is built-in. T wo diff ...

  • York 48 - page 7

    254597-YTG-B-0507 Unitary Products Group 7 FIELD-INST ALLE D ACCESSORIES • SINGLE INPUT ELECTR ONIC ENTHALPY ECONO- MIZERS - Includes a slide-in / plug-in damper a ssembly with fully modulating spring-return motor actuator capa- ble of introducing up to 100% outdoor air with nominal 1% leakage type dampers. The enthalpy system co ntains one senso ...

  • York 48 - page 8

    254597-YTG-B-0507 8 Unitary Products Group T AB LE 1: SOUND POWER RA TING 1 UNIT SIZE CFM ESP BLOWER SOUND POWER (db 10 -12 Wat ts ) Octave Band Centerline Frequency (Hz) SWL dB(A) dB(A) @ 10Ft. 2 IWG SPEED KW 63 125 250 500 1,000 2,000 4,000 8,000 036 1,200 0.6 LOW 0.60 84 84 74 67 69 62 57 52 74 41 048 1,600 0.55 HIGH 0.80 85 85 75 68 70 63 58 53 ...

  • York 48 - page 9

    254597-YTG-B-0507 Unitary Products Group 9 T AB LE 5: DH036 COOLING CAP ACITIES (3 TON) CFM WB °F 86 83 80 77 74 71 68 86 83 80 77 74 71 68 72 55.2 3.18 35.2 30.7 26.2 21.8 17.3 - - 51.5 3.44 34.1 29.7 25.2 20.7 16.2 - - 67 49.1 3.13 41.7 37.2 32.8 28.3 23.8 19.4 14.9 45.8 3.35 40.2 35.7 31.3 26.8 22.3 17.8 13.4 62 44.7 3.05 44.7 43.6 39.1 34.6 30 ...

  • York 48 - page 10

    254597-YTG-B-0507 10 Unitary Products Group T AB LE 6: DH048 COOLING CAP ACITIES (4 TON) CFM WB °F 86 83 80 77 74 71 68 86 83 80 77 74 71 68 72 59 3.3 46 40 34 28 23 - - 55 3.5 43 37 32 26 20 - - 67 53 3.2 53 49 43 38 32 26 21 49 3.4 49 47 41 35 30 24 62 47 3.2 47 47 47 42 36 30 25 44 3.4 44 44 44 38 32 26 57 47 3.1 47 47 47 41 35 29 24 43 3.3 43 ...

  • York 48 - page 11

    254597-YTG-B-0507 Unitary Products Group 11 T AB LE 7: DH060 COOLING CAPACITIES (5 T ON) CFM WB °F 86 83 80 77 74 71 68 86 83 80 77 74 71 68 72 82 4.3 56 50 43 37 30 - - 76 4.6 54 48 41 34 28 - - 67 70 4.2 67 61 54 48 41 34 28 65 4.5 65 58 51 45 38 31 25 62 67 4.0 67 67 66 59 52 46 39 62 4.5 62 62 62 55 49 42 35 57 66 4.0 66 66 66 59 52 46 39 61 4 ...

  • York 48 - page 12

    254597-YTG-B-0507 12 Unitary Products Group T AB LE 8: SUPPLY AIR BLOWER PERFORMANCE (3 TO N BELT DRIVE) - SIDE DUCT APPLICATION RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS 2000 843 860 880 925 919 1005 956 1065 993 1145 1030 1195 1067 1235 1900 817 775 854 850 893 920 930 995 970 1065 1008 1125 1046 1170 1800 790 700 828 ...

  • York 48 - page 13

    254597-YTG-B-0507 Unitary Products Group 13 T AB LE 10: SUPPLY AIR BLOWER PERFORMANCE (5 TON BELT DRIVE) - SIDE DUCT APPLICATION RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS RPM WATTS 2500 1059 1560 1077 1590 1095 1630 1114 1650 1134 1660 1158 1685 1181 1720 2400 1032 1405 1054 1470 1074 1525 1094 1560 1116 1595 1140 1620 1167 1640 2 ...

  • York 48 - page 14

    254597-YTG-B-0507 14 Unitary Products Group T AB LE 12: BEL T DRIVE BLOWER MOTOR AND DRIVE DA T A MODEL SIZE BLOWER RANGE (RPM) MOTOR 1 ADJUST A BLE MOTOR PULLEY FIXED BLOWER PULLEY BEL T (NOTCHED) HP FRAME DESIG- NA TION OUTSIDE DIA. (IN.) PITCH DIA. (IN.) BORE (IN.) DESIG- NA TION OUTSIDE DIA. (IN.) PITCH DIA. (IN.) BORE (IN.) DESIG- NA TION PITC ...

  • York 48 - page 15

    254597-YTG-B-0507 Unitary Products Group 15 T AB LE 15: ELECTRICAL DA T A - DH036 , 048 & 060 DIRECT DRIVE W/O POWERED CONVENIENCE OUTLET MODEL TONNAGE VOL T AGE COMPRES SORS OD F A N MOTOR FLA ID BLOWER MOTOR FLA CONV OUTLET FLA ELECTRIC HEA TER MODEL NO. HEA TER KW HEA TER AMPS MIN. CIRCUIT AMP ACITY (AMPS) MAX. FUSE/ BRKR 1 SIZE (AMPS ) RLA ...

  • York 48 - page 16

    254597-YTG-B-0507 16 Unitary Products Group T AB LE 16: ELECTRICAL DA T A - DH036-060 BEL T DRIVE W/O POWERED CONV EN IENCE OUTLET MODEL TONNAGE VOL T AGE COMPRES SORS OD F A N MOTOR FLA ID BLOWER MOTOR FLA CONV OUTLET FLA ELECTRIC HEA TER MODEL NO. HEA TER KW HEA TER AMPS MIN. CIRCUIT AMP ACITY (AMPS) MAX. FUSE/ BRKR 1 SIZE (AMPS ) RLA EACH LRA EA ...

  • York 48 - page 17

    254597-YTG-B-0507 Unitary Products Group 17 T AB LE 17: ELECTRICAL DA T A - DH036, 048 & 06 0 DIRECT DRIVE W/POWERED CONVENIENCE OUTLET MODEL TONNAGE VOL T AGE COMPRES SORS OD F A N MOTOR FLA ID BLOWER MOTOR FLA CONV OUTLET FLA ELECTRIC HEA TER MODEL NO. HEA TER KW HEA TER AMPS MIN. CIRCUIT AMP ACITY (AMPS) MAX. FUSE/ BRKR 1 SIZE (AMPS ) RLA EA ...

  • York 48 - page 18

    254597-YTG-B-0507 18 Unitary Products Group T AB LE 18: ELECTRICAL DA T A - DH036-060 BE L T DRIVE W/POWERED CONV ENIENCE OUTLET MODEL TONNAGE VOL T AGE COMPRES SORS OD F A N MOTOR FLA ID BLOWER MOTOR FLA CONV OUTLET FLA ELECTRIC HEA TER MODEL NO. HEA TER KW HEA TER AMPS MIN. CIRCUIT AMP ACITY (AMPS) MAX. FUSE/ BRKR 1 SIZE (AMPS ) RLA EACH LRA EACH ...

  • York 48 - page 19

    254597-YTG-B-0507 Unitary Products Group 19 T ABLE 19: PHYSICAL DATA MODELS DH 036 048 060 EV APORA TOR BLOWER Centrifug al Blower (Dia . x Wd. in.) 12 X 10 12 X 10 12 X 10 Fan Motor HP (Dire c t Drive) 3/4 1 1 Fan Motor HP (Belt Driv e) 1 1/2 1 1/2 1 1/2 EV APORA TOR COIL Rows Deep 4 4 4 Fins Per Inc h 13 13 13 Face Area (Sq. Ft.) 4.3 5.1 5.1 COND ...

  • York 48 - page 20

    254597-YTG-B-0507 20 Unitary Products Group FIGURE 2 - TYPICA L FIELD POWER & CONTROL WIRING RC RH Y1 Y2 W1 W2 G LED 1 LED 2 COM A1 A2 T T B R Y1 Y2 G C X OCC W2 W1 THERMOSTAT 1 TERMINALS UNIT TERMINAL STRIP TB1 24 VOLT TRANSFORMER TO REMOTE SENSOR 2TH040702224 IF USED NOT USED ADD JUMPER ADD JUMPER 4 4 3 2 1 ELECTRONIC PROGRAMMABLE THERMOSTAT ...

  • York 48 - page 21

    254597-YTG-B-0507 Unitary Products Group 21 FIGURE 3 - UNIT DIMENSIONS (3 - 5 T O N COOLING ONL Y/ELECTRIC HEA T) FRONT VIEW FIGURE 4 - UNIT DIMENSIONS (3 - 5 T ON COOLING/GAS HEA T) FRONT VIEW ...

  • York 48 - page 22

    254597-YTG-B-0507 22 Unitary Products Group FIGURE 5 - UNIT WITH ECONOMIZER RAINHOOD FIGURE 6 - UNIT WITH FIXED OUT D OOR AIR/MOTORIZE D DAMPER RAINHOOD DETAIL “A” DETAIL “B” ...

  • York 48 - page 23

    254597-YTG-B-0507 Unitary Products Group 23 FIGURE 7 - UNIT DIMENSIONS (REAR VIEW) FIGURE 8 - DISCONNECT/BLOWER ACCESS LOCA TION T ABLE 22: UTILITIES ENTR Y HOLE OPENING SIZE (DIA.) USED FOR A 7/8” KO 1 1. Opening in the bottom to the unit can be located by the side in the insulation. Control Wi ri ng 2 2. Do not remove the 2” knockout ring. Si ...

  • York 48 - page 24

    254597-YTG-B-0507 24 Unitary Products Group FIGURE 9 - TYPICAL APPLICA TIONS ...

  • York 48 - page 25

    254597-YTG-B-0507 Unitary Products Group 25 FIGURE 10 - FOUR AND SIX POINT LOADING 44 7 / 8 82 1 / 4 Y X A B C D CONDENSER COIL END OF UNIT FRONT OF UNIT APPROXIMATE CENTER OF GRAVITY BACK OF UNIT 44 7 / 8 82 1 / 4 Y X A B C D E F CONDENSER COIL END OF UNIT FRONT OF UNIT APPROXIMATE CENTER OF GRAVITY BACK OF UNIT T AB LE 24: DH 4 AND 6 POINT LO ADS ...

  • York 48 - page 26

    254597-YTG-B-0507 26 Unitary Products Group T ABLE 26: OPERA TING WEIGHTS (LBS.) MOD E L S IZ E 3 TON 4 TO N 5 TO N BASIC UNIT DH (Cool ing Only) 565 61 0 64 5 DH (Gas/Electric) N04 605 - - N06 - 660 - N08 625 - 705 N10 - 680 715 D06 615 660 695 D10 635 680 715 OPTIONS Economizer 50 26 18 23 28 92 10 5 Motorized Damper Electric H eater 5 - 7 kW 10 ...

  • York 48 - page 27

    254597-YTG-B-0507 Unitary Products Group 27 GUIDE SPECIFICA TIONS GENERAL Units shall be manufactured by Y ork International Unitary Products Group in an ISO 9001 certified facility . Y ork's Sunline Ultra ® units are convertibl e single package units. Although the units are primarily designed for curb mounting on a roof, they can also be sla ...

  • York 48 - page 28

    254597-YTG-B-0507 28 Unitary Products Group Coils: a. Evaporator and conde nser coils shall have alumi- num plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed. S pecial Phenolic coating shall be available as a factory option. b. Evaporator and Condenser coil s shall be of the direct expansion, draw-th ...

  • York 48 - page 29

    254597-YTG-B-0507 Unitary Products Group 29 ST AND ARD LIMITED W ARRANTIES • Compressor 5 Y ears • Heat Exchanger 10 Y ears • Electric Heat Element 5 Y ears • Other Part s 1 Y ear OPTIONAL OUTDOOR AIR (Shall be made availa ble by either/or): • ELECTRONIC ENTHALPY AUT OMA TIC ECONO- MIZER - Outdoor and return air dampers that are inter- lo ...

  • York 48 - page 30

    254597-YTG-B-0507 30 Unitary Products Group • TECHNICOA T PHENOLIC COA TED CONDENSER AND EV APORA TOR COIL • ELECTRONIC SINGLE ENTHALPY ECONOMIZER • DIRTY FIL TER SWITCH • PHASE MONITOR • COIL GUARD • POWERED GFI CONVENIENCE OUT LET • NON-POWERED GF I CONVENIENCE OUTLET • BAS CONTROLS ( Simplicity ® INTELLI-Comfort™, CPC, JOHNSON ...

  • York 48 - page 31

    254597-YTG-B-0507 Unitary Products Group 31 ...

  • York 48 - page 32

    Subject to change without notice. Printed in U.S.A. 254597-YTG-B-0507 Copyright © 2007 by Unitary Products Group. All rights reserved. Supersedes: 254597-YTG-A-0306 Unitary 5005 Norman Product s Y ork O K Group Drive 73069 ...

Fabbricante York Categoria Air Conditioner

I documenti che otteniamo dal fabbricante del dispositivoYork 48 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici York
- manuali per l’uso 48
- schede prodotto York
- opuscoli
- o etichette energetiche York 48
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso York 48.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione York 48, manuali di manutenzione, brevi manuali o manuali utente York 48. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto York 48.

Manuali per l’uso simili

Manuale completo del dispositivo York 48, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare York 48 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti York 48.

Il manuale per l’uso completo York, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale York 48 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice York 48, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per York 48 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo York 48 - che ci dovrebbe aiutare nei primi passi durante l'uso York 48
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del York 48
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio York 48 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su York 48?

Utilizza il modulo sottostante

Se non hai risolto il problema con York 48 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con York 48 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)