  • Thermo Products R-410A - page 1

    835961-UIM-D-0213 R-410A OUTDOOR SPLIT -SYSTEM HEA T PUMP MODELS: 13 SEER & 14.5 SEER - THG(D,F)/GHG D/ THJ(D,F)/YHJ(D, F)/YHJR/THJ R SERI ES 1.5 TO 5 TONS – 1 & 3 PHASE INSTALLATION MANUAL ® LIST OF SECTIONS GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 SAFETY . . . . . . . . . . . ...

  • Thermo Products R-410A - page 2

    835961-UIM-D-0213 2 Johnson Controls Unitary Products Requirements For Inst alling/Servicing R-410A Equipment • Gauge sets, hoses, refrigerant containers, and recovery system must be designed to handle the POE type oils, and the higher pressures of R-410A. • Manifold sets should be 800 psig high side and 250 psig low side with 550 psig low side ...

  • Thermo Products R-410A - page 3

    835961-UIM-D-0213 Johnson Controls Unitary Produ cts 3 GROUND IN ST ALLA TION The unit may be installed at ground level on a solid b ase that will not shift or settle, causing strain on t he refrigerant lines and possible leaks. Maintain the clearances shown in Figure 1 and install the unit in a level position. Normal operating sound levels may be ...

  • Thermo Products R-410A - page 4

    835961-UIM-D-0213 4 Johnson Controls Unitary Products PRECA UTIONS DURING BRAZING OF LINES All outdoor unit and evaporator co il connections are copper-to-coppe r and should be brazed with a phosphor ous-copper alloy material such as Silfos-5 or equivalent. DO NOT use soft solder . T he outdoor unit s have reusable service valves on bot h the liqui ...

  • Thermo Products R-410A - page 5

    835961-UIM-D-0213 Johnson Controls Unitary Produ cts 5 SECTION IV : ORIFICE INST ALLA TION Install Schrader V alve Core and Orifice as follows: 1. Relieve the holding charge by depressing the Schrader valve stem located in the end of the liquid line. Cut the sp undown copper to allow installation of the suction line. 2. Slide indoor coil out of cab ...

  • Thermo Products R-410A - page 6

    835961-UIM-D-0213 6 Johnson Controls Unitary Products SECTION VI: EV ACU A TION It will be necessary to evacuate the system to 500 microns or less. If a leak is suspected, leak test with dry nitrogen to locate the leak. Repair the leak and test again. T o verify that the system has no leak s, simply close the valve to the vac- uum pump suction to i ...

  • Thermo Products R-410A - page 7

    835961-UIM-D-0213 Johnson Controls Unitary Produ cts 7 SECTION VIII: ELECTRICAL CONNECTIONS GENERAL INFORMA TION & GROUNDING Check the electrical supply to be sure that it meets the values specified on the unit nameplate and wiring lab el. Power wiring, control (low voltage) wiring, disconnect switches and over current protection must be suppli ...

  • Thermo Products R-410A - page 8

    835961-UIM-D-0213 8 Johnson Controls Unitary Products DEHUMIDIF ICA TION CON TROL A dehumidification control accessory 2HU06700124 may be used with variable speed air handlers or fur naces in high humidity areas. This control works with the variable speed indoor unit to provide cooling at a reduced air flow , lowering evaporator temperature and inc ...

  • Thermo Products R-410A - page 9

    835961-UIM-D-0213 Johnson Controls Unitary Produ cts 9 SECTION IX: SY STEM ST ART -UP ENERGIZE CRANK CASE HEA TER If this unit is equipped wi th a crankcase heater for the compressor, a warning label with an adhesive back is supplied in the u nit installation instruction packet. This label shoul d be attached to the field supplied disconnect switch ...

  • Thermo Products R-410A - page 10

    835961-UIM-D-0213 10 Johnson Controls Unitary Products SECTION V : SY STEM OPERA TI ON ANTI-SHO RT CY CLE DE LA Y The control includes a five-minute anti-short cycle delay (ASCD) time r to prevent the compressor from shor t cycling after a power or thermo- stat signal interruption. The ASCD time r is applied when the control is first powered from t ...

  • Thermo Products R-410A - page 11

    835961-UIM-D-0213 Johnson Controls Unitary Produ cts 11 Demand Defrost (13 Se er 1.5 ton, 14.5 Seer 1 .5-4 T on) The control maintains proper airflow through the outdoor coil during heating operation by melting frost and ice that may fo rm on the coil. Frost may accumulate unevenly in diff erent sections of the coil because of the arrangement of th ...

  • Thermo Products R-410A - page 12

    835961-UIM-D-0213 12 Johnson Controls Unitary Products COOLING OPERA TION During cooling operation, the control will receive thermostat signals at the Y and O input terminals. T he control will energize the M compressor output terminal. This signal energ izes the coil of the compressor con- tactor causing the compressor to run. The control also del ...

  • Thermo Products R-410A - page 13

    835961-UIM-D-0213 Johnson Controls Unitary Produ cts 13 SECTION VII: WIRING DIA GRAM FIGURE 14: Wiring Diagram - Single Phase (De mand Defrost) ...

  • Thermo Products R-410A - page 14

    835961-UIM-D-0213 14 Johnson Controls Unitary Products FIGURE 15: Wiring Diagram - Single Phase (Time-T emp) 544123-UWD-B-0412 S C R FAN MOTOR GND 63 54 2 1 GRN BRN RED BLK BRN WHT S C R BRN CAP H C F RED L1 L2 T1 T2 USE COPPER CONDUCTORS ONLY 208-230 VAC 60 Hz 1 PHASE SUPPLY CC CCH COMPRESSOR PLUG CONTACTOR RED RED RED BLK BLK RED RED BLK BLK BLK ...

  • Thermo Products R-410A - page 15

    835961-UIM-D-0213 Johnson Controls Unitary Produ cts 15 FIGURE 16: Wiring Diagram - Three Phase (Demand Defrost) R C GND FAN MOTOR S 56 34 2 1 BRN RED GRN BLK USE COPPER CONDUCTORS ONLY 208/230 VAC 60 HZ 3 PHASE SUPPLY 460 VAC 60 HZ 3 PHASE SUPPLY 380/415 VAC 50 HZ 3 PHASE SUPPLY COMPRESSOR FIELD WIRING, LINE VOLTAGE OPTIONAL WIRING LOW VOLTAGE FAC ...

  • Thermo Products R-410A - page 16

    835961-UIM-D-0213 16 Johnson Controls Unitary Products FIGURE 17: Wiring Diagram - Three Phase (T ime-T emp) 545127-UWD-C-0412 R C GND FAN MOTOR S 56 34 2 1 BRN RED GRN BLK T2 T1 T3 RED USE COPPER CONDUCTORS ONLY 208-230 VAC 60 Hz 3 PHASE SUPPLY 460 VAC 60 Hz 3 PHASE SUPPLY 575 VAC 60 Hz 3 PHASE SUPPLY 380/415 VAC 60 Hz 3 PHASE SUPPLY COMPRESSOR PL ...

  • Thermo Products R-410A - page 17

    835961-UIM-D-0213 Johnson Controls Unitary Produ cts 17 NOTES ...

  • Thermo Products R-410A - page 18

    835961-UIM-D-0213 18 Johnson Controls Unitary Products SECTION VIII: ST ART UP SHEET Heat Pump and Supplementary Heat Start-Up Sheet Proper start-up is critical to customer comfort and equipment longevity Name Address City State or Province Zip or Postal Code Indoor Unit Model # Indoor Unit Serial # Indoor Coil Model # Indoor Coil Serial # Upflow D ...

  • Thermo Products R-410A - page 19

    835961-UIM-D-0213 Johnson Controls Unitary Produ cts 19 Supply static after indoor coil (in w.c.") Return Static (in w.c.") before filter Total External Static Pressure Low 1 2 Medium Low Medium 3 4 Medium High High 5 A B D C A B C D Air Side: System Total External Static Pressure Supply static before indoor coil (in w.c.") Return St ...

  • Thermo Products R-410A - page 20

    Subject to change without not ice. Published in U.S.A. 835961-UIM-D-0213 Copyright © 2013 by Johnson Controls, Inc. All rights reserved. Supersedes: 835961-UIM-C-0712 Y ork Internationa l Corp. 5005 Y ork Drive Norman, OK 73069 Explain operation of system to equipment owner Explain the importance of regular filter replacement and equipment mainten ...

Fabbricante Thermo Products Categoria Marine Sanitation System

I documenti che otteniamo dal fabbricante del dispositivoThermo Products R-410A possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Thermo Products
- manuali per l’uso R-410A
- schede prodotto Thermo Products
- opuscoli
- o etichette energetiche Thermo Products R-410A
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Thermo Products R-410A.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Thermo Products R-410A, manuali di manutenzione, brevi manuali o manuali utente Thermo Products R-410A. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Thermo Products R-410A.

Manuale completo del dispositivo Thermo Products R-410A, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Thermo Products R-410A dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Thermo Products R-410A.

Il manuale per l’uso completo Thermo Products, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Thermo Products R-410A - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Thermo Products R-410A, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Thermo Products R-410A che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Thermo Products R-410A - che ci dovrebbe aiutare nei primi passi durante l'uso Thermo Products R-410A
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Thermo Products R-410A
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Thermo Products R-410A in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Thermo Products R-410A?

Utilizza il modulo sottostante

Se non hai risolto il problema con Thermo Products R-410A con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Thermo Products R-410A è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)