    SR785 T wo Channel Dynamic Signal Analyzer SRS STANFORD RESEARCH SYSTEMS ...

  • SRS Labs SR785 - page 2

    SR785 T wo Channel Dynamic Signal Analyzer $11,950 (U.S. list) Features ● FFT , Correlation and Order T racking Measurements ● ANSI Standard 1/1, 1/3, 1/12 Octave Analysis ● Swept-Sine Mode (145 dB dynamic range) ● 20-pole/20-zero Curve Fit and Synthesis ● Time/Histogram Mode ● Windows95 ¨ DataViewer ● Output to SDF ¨ , MA T ¨ , UF ...

  • SRS Labs SR785 - page 3

    F ast Responsive Mark er • Find Max/Min or track peaks • THD, THD + N • Band, sideband, harmonic power • Waterfall • Frequency and damping • Peak find • Absolute and relative • Statistics Input Channels • Dual ADCs provide 102.4 kHz bandwidth on both channels simultaneously. • -50 dBV max full scale input sensitivity • Built-i ...

  • SRS Labs SR785 - page 4

    SR785 T wo Channel Dynamic Signal Analyzer FFT Spectrum Analysis The SR785 Two Channel Dynamic Signal Analyzer is a precision, full-featured signal analyzer that offers state-of-the-art performance and a wide selection of features at a price that's less than half that of competitive analyzers. Building on its predecessor, the SR780, the SR785 ...

  • SRS Labs SR785 - page 5

    View order maps or track individual orders with the SR785. Run-up and run-down measurements in both polar and bode formats are available. time record, 1000 averages take exactly 4 seconds, during which the SR785 still operates at its maximum display rate. For impact testing, the average preview feature allows each time record or spectrum to be acce ...

  • SRS Labs SR785 - page 6

    provided to monitor variations of RPM as a function of time. And a complete selection of time and RPM triggering modes is included allowing you to make virtually any rotating machinery measurement. Swept-Sine Measurements Network analysis using FFT mode produces fast results but suffers from limited dynamic range and frequency resolution. Swept-sin ...

  • SRS Labs SR785 - page 7

    Top display shows the burst noise source. Bottom display shows an arbitrary waveform downloaded to the SR785 via the IEEE-488 interface. Top display shows a histogram of time data. Bottom display shows the cumulative density function. user-defined thresholds are measured with high frequency resolution, while small changes are measured using wider f ...

  • SRS Labs SR785 - page 8

    Two 2k deep waterfall buffers ensure you’ll never miss important waterfall data. The SR785 doesn’t limit you to a few preselected measurements. With user math you can create an infinite variety of measurements. Wa t e r f a l l Waterfall plots are a convenient way of viewing a time history of your data. Each successive measurement record is plo ...

  • SRS Labs SR785 - page 9

    Output The SR785's built-in 3.5" 1.44 MB disk drive, GPIB and RS-232 computer interfaces and Centronics printer port combine to allow almost unlimited flexibility in saving, printing, plotting or exporting your measurement data. Displays and setups can be printed or plotted to disk, GPIB, RS-232 or Centronics port in PCX, GIF, PCL (LaserJ ...

  • SRS Labs SR785 - page 10

    The SRS DataViewer Windows utility enables you to view SR785 data files graphically and save them in different formats. DataViewer The SRS DataViewer is a Windows 95 program that allows you to quickly upload SR785 files into a graphical environment, perform simple editing and cut and paste into other applications. You can add pointers and text, cha ...

  • SRS Labs SR785 - page 11

    SR785 Specifications Specifications apply after 30 minutes of warm-up and within two hours of last auto-offset. All specifications are with 400 line FFT resolution and anti-alias filters enabled unless stated otherwise. Measurement Groups Standard Groups FFT analysis, Correlation, Time Histogram, Swept Sine Optional Group Order Tracking Frequency R ...

  • SRS Labs SR785 - page 12

    Flatness <0.25 dB pk-pk (typical), <1.0 dB pk-pk (max), 5000 rms averages Pink Noise Source Bandwidth DC to 102.4 kHz Flatness <2.0 dB pk-pk, 20 Hz - 20 kHz (measured using averaged 1/3 octave analysis) Chirp Source Time Record Continuous or Burst Output Sine sweep across the FFT span Flatness ±0.25 dB, 1.0 Vpk Swept Sine Source Auto Func ...

  • SRS Labs SR785 - page 13

    SR785 Features Instrument Modes FFT, Time/Histogram, Correlation, Octave, Swept-Sine, Order Tracking Frequency Domain Measurements Frequency Response, Linear Spectrum, Cross Spectrum, Power Spectrum, Coherence, Power Spectral Density Time Domain Measurements Time Record, Cross Correlation, Auto Correlation, Orbit Amplitude Domain Measurements Histo ...

  • SRS Labs SR785 - page 14

    1290 D Reamwood Avenue ¥ Sunnyvale, CA 94089 Telephone (408)744-9040 ¥ FAX: (408)744-9049 Email: info@srsys.com ¥ WWW: www.srsys.com Printed in USA ©1998 Stanford Research Systems, Inc. All specifications and prices subject to change (1/98) All trademarks are the property of their respective owners. SRS STANFORD RESEARCH SYSTEMS Ordering Inform ...

Fabbricante SRS Labs Categoria Stereo System

I documenti che otteniamo dal fabbricante del dispositivoSRS Labs SR785 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici SRS Labs
- manuali per l’uso SR785
- schede prodotto SRS Labs
- opuscoli
- o etichette energetiche SRS Labs SR785
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso SRS Labs SR785.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione SRS Labs SR785, manuali di manutenzione, brevi manuali o manuali utente SRS Labs SR785. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto SRS Labs SR785.

Manuali per l’uso simili

Manuale completo del dispositivo SRS Labs SR785, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare SRS Labs SR785 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti SRS Labs SR785.

Il manuale per l’uso completo SRS Labs, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale SRS Labs SR785 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice SRS Labs SR785, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per SRS Labs SR785 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo SRS Labs SR785 - che ci dovrebbe aiutare nei primi passi durante l'uso SRS Labs SR785
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del SRS Labs SR785
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio SRS Labs SR785 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su SRS Labs SR785?

Utilizza il modulo sottostante

Se non hai risolto il problema con SRS Labs SR785 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con SRS Labs SR785 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)