Manuale per l’uso Baldor MN806

12 pagine 0.05 mb
Scarica

Vai alla pagina of 12

Summary
  • Baldor MN806 - page 1

    SOLID ST A TE ST AR TER P AR TS BREAKDOWN BY PRODUCT LINE MN806 Printshop 2000 7/96 ...

  • Baldor MN806 - page 2

    T able of Contents Contr ol T ype . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section Dynamic Brakes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B Def inite Pur pose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .D General Purpose ...

  • Baldor MN806 - page 3

    B-1 B 7 1 C P Brake V oltage 7 - 208/230/460 V A C AMP Size 0 - 8 AMPS 1 - 16 AMPS 2 - 30 AMPS 3 - 55 AMPS 4 - 135 AMPS C - Control only Enclosure T ype A - Open B - NEMA 1 C - NEMA 12 D - NEMA 4 P - P ANEL Dynamic Brakes There are 2 styles of brakes b uilt by Baldor . V erify the type of brake first. Old Style The “old style” brake has most pa ...

  • Baldor MN806 - page 4

    B-2 1 If the SCR/Diode are replaced an SCR kit is also required. A A Braking Module This module is not av ailable. If the module can not be repaired the brake must be replaced. Sizes 0, 1 and 2 hav e the SCRs in the module and can be replaced. Size 0, 1 and 2 D Braking Contactor Over a 15 year period se v eral brands of contactors ha ve been used. ...

  • Baldor MN806 - page 5

    D-1 TYPE OF CONTROL D - Definite Purpose Control DEFINITE PURPOSE D 7 0 C A A Module (LCM) *TYPE SIZE AMP 60Hz 50Hz I 0,1,2 8,16,30 REPLA CE ENTIRE UNIT II 3,4 50,70 D8X D9X III, IV 3,4,5 50,70, L8X L9X 135 B SCR/Po wer Cell(s) C F ans D MO V -All Sizes E Thermostat F Line Load T erminals *TYPE SIZE AMP P AR T III, IV 3,4,5 50,70,135 TSW0010 INPUT ...

  • Baldor MN806 - page 6

    D-2 Def inite Pur pose Contr ols Refer ence I II III IV OPEN 8-70 AMP NEMA 12/3R 135 AMP P ANEL AND NEMA 1 50 AND 70 AMP P ANEL AND NEMA 1 30 AMP 8 AND 16 AMP A B A C E B C A E F G F G F F E E E G F F ...

  • Baldor MN806 - page 7

    G-1 G 7 6 A B T ype of Control G - General Purpose M - Multipurpose (Non UL) R - Ramp up / Ramp down V oltage Code 1 - 208 60Hz 2 - 230 60Hz 3 - 380 50Hz 4 - 400 50Hz 5 - 460 60Hz 6 - 575 60Hz 7 - 208/230/460 60Hz 8 - 230/460/575 60Hz 9 - 220/380 50Hz AMP Size G and R M AMP Rating 0A 8 1B 1 6 2C 3 0 3D 5 5 –E 8 0 4 F 135 5 G 250 6 H 400 7 J 700 G ...

  • Baldor MN806 - page 8

    G-2 CT1 CT1 CT2 General Purpose/Ramp Up - Ramp Do wn and non UL V ersions of Multipurpose Contr ol Size 0, 1 Size 2 Size 3 Size 4, 5, 6, 7 F G A A G F F A K B D D J H G G G J C E E E F D D K A B J C H E G ...

  • Baldor MN806 - page 9

    G-3 A Control Module The Control Module is no longer av ailable. The Multipurpose module can be used as a replacement. For sizes 0, 1, 2 (G and R controls), a replacement control is required. For sizes 4-7 and D-J a replacement module can be used. For 60Hz applications use the MB8X, and for 50Hz applications use the MB9X. A con version manual is in ...

  • Baldor MN806 - page 10

    G-4 6 Po wer Cells and SCRs CONTR OL TYPE PO WER CELL REPLA CEMENT SCR AMP NON UL MAX SIZE G and R M V A C CA T . NO. CA T . NO. 8, 16 0, 1 A, B 460 – SCR0005 575 – SCR0010 30 20 C 466 – SCR0015 575 – SCR0020 55 3 D 460 PC1B SCR0025(3) 575 PC1B SCR0025(3) 80 – E 460 PC2B SCR0130(3) 575 PC2B SCR130(3) 135 4 ➀ F ➀ 460 PC4A SCR0055(2) 57 ...

  • Baldor MN806 - page 11

    G-5 K Control T ransf ormers Control T ransformers are locally av ailable. Baldor stocks simular transformers byt may require panel modification to f it. SIZE GENERAL RAMP NON UL UL PURPOSE UP/DO WN MUL TIPURPOSE MUL TIPURPOSE 0 G70** R70** MA7A** MA7-008-** 1 G71** R71** MA7B** MA7-016-** 2 G72** R72** MA7C** MA7-030-** 3 G73** R73** MA7D** MB7-05 ...

  • Baldor MN806 - page 12

    G-5 K Control T ransf ormers Control T ransformers are locally av ailable. Baldor stocks simular transformers byt may require panel modification to f it. SIZE GENERAL RAMP NON UL UL PURPOSE UP/DO WN MUL TIPURPOSE MUL TIPURPOSE 0 G70** R70** MA7A** MA7-008-** 1 G71** R71** MA7B** MA7-016-** 2 G72** R72** MA7C** MA7-030-** 3 G73** R73** MA7D** MB7-05 ...

Fabbricante Baldor Categoria Battery Charger

I documenti che otteniamo dal fabbricante del dispositivoBaldor MN806 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Baldor
- manuali per l’uso MN806
- schede prodotto Baldor
- opuscoli
- o etichette energetiche Baldor MN806
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Baldor MN806.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Baldor MN806, manuali di manutenzione, brevi manuali o manuali utente Baldor MN806. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Baldor MN806.

Manuali per l’uso simili

Manuale completo del dispositivo Baldor MN806, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Baldor MN806 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Baldor MN806.

Il manuale per l’uso completo Baldor, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Baldor MN806 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Baldor MN806, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Baldor MN806 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Baldor MN806 - che ci dovrebbe aiutare nei primi passi durante l'uso Baldor MN806
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Baldor MN806
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Baldor MN806 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Baldor MN806?

Utilizza il modulo sottostante

Se non hai risolto il problema con Baldor MN806 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Baldor MN806 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)