  • ResMed ST - page 1

    VP AP™ A uto 25 VP AP™ S T VP AP™ S Positive Airw A y Pressure device User Guide English ...

  • ResMed ST - page 2

    English VP AP™ A uto 25 VP AP™ S T VP AP™ S POSITIVE AI RWA Y PRES SURE DEVICE User Guide English ResMed Ltd (Manufacturer) 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia ResMed Corp (US Designated Agent) 14040 Danielson Street Poway CA 92064-6857 USA ResMed (UK) Ltd (EU Authorized Representative) 96 Milton Park Abingdon Oxfordshi ...

  • ResMed ST - page 3

    Cont ents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Contraindications 1 Adv erse Ef f ects 1 The VP AP S ystem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Masks 2 Humidifier 2 ResScan Data Card 2 Supplemental Oxygen 3 Using the VP AP Auto 25 ...

  • ResMed ST - page 4

    1 Introduction English Introduction The VPAP TM Auto 25 , VPAP TM ST and the VPAP TM S are i ndicated for the tre atment of obstructive sleep ap nea (OSA) in patients weighing more than 66 lb (30 kg). They are intended for home and hospital use. Contraindications Positive airwa y pressure therapy may be contraindicated in some patients with the fol ...

  • ResMed ST - page 5

    2 Masks The following Re sMed mask systems are re commended for use with these devices: For information on using masks, see your mask manual. For the latest avai lable masks, see www.resmed.com. Humidifier If you are experie ncing dryness of the nose, throat or mouth, the H4i heated humidifier is recommended for use with these VP AP devices. ! WARN ...

  • ResMed ST - page 6

    3 Using the VP AP Auto 25, VP AP ST & VP A P S English Supplemental Oxygen The VPAP Auto 25, VPAP ST and VPAP S are designed to be compatible with the following levels of supplemental oxygen usage: • Up to 4 L/mi n in V Auto mode • Up to 1 5 L/min in CP AP , S, ST and T modes. At a fixed flow rate of supplemental oxygen flow, the inhaled ox ...

  • ResMed ST - page 7

    4 ! CAUTION • Be careful not to place the device where it can be bu mped or where someone is likely to trip over the power cord. • If you put the device on the floo r , mak e sure the area is free from dust and clear of bedding, clot hes or other objects that could bloc k the air inlet. Attaching a H4i Humidifier The H4i humidifier attaches to ...

  • ResMed ST - page 8

    5 Using the VP AP Auto 25, VP AP ST & VP A P S English Using the Menus The VPAP Auto 25 , VPAP ST and VPAP S provide a set of functions which are arranged in menus and submenus. Vi a the LCD screen, the menus and submenus allow you to view and change the settings for a particul ar function. To navigate and make selections with in the Patient Me ...

  • ResMed ST - page 9

    6 How to Select the Mask Type Scroll to MASK and select . Press or until you see the setting you require. The fo llowing table shows the setting that should be selec ted for each mask: How to change the EPR level (CPAP mode) Expiratory Pressure Relief (EP R) can be used to improve your comfort level when breathing out during treatment. If patient a ...

  • ResMed ST - page 10

    7 Using the VP AP Auto 25, VP AP ST & VP A P S English Starting Treatment 1 Make sure the power is on. The product name is displayed briefly on the LCD screen , then the standby (Ramp/ Settle) screen appears. The key and LCD backlights also turn on. 2 Fit your mask as d escribed in the mask user instructions. ! WARNING A mask should no t be use ...

  • ResMed ST - page 11

    8 Using the Mask-Fitting feature The VPAP Auto 25, VPAP ST and VPAP S include a m ask-fitting feature to he lp you fit your mask properly. The mask-fitting fe ature delivers air pressu re for a three- minute period, prior to starting treatment, for checking and adjusting your mask fit to minimize leaks. To use the mask-fitting feature: 1 Fit your m ...

  • ResMed ST - page 12

    9 Using the VP AP Auto 25, VP AP ST & VP A P S English Using the Data Card If your clinician needs to review your treatment, they wil l ask you to use the Data Card to copy data from your VPAP device and return th e card to them. Copying Data onto a Data Card 1 Switch on your VPAP and wai t until you see the standby (Ramp/Settle) screen. 2 Hold ...

  • ResMed ST - page 13

    10 Traveling with the VPAP Auto 25, VPAP ST & VPAP S International Use Your VPAP flow generator has an internal pow er adapter that enables it to operate i n other countries. It will operate on power supplies of 100–240V and 50–60Hz. No special adjustment i s necessary, but you wil l require an approved power co rd for that country. Use on ...

  • ResMed ST - page 14

    11 Cleaning and Maintenance English Cleaning and Maintenance You should regularly carry out the cleaning and mainte nance described in this section. Refer to your mask and humidifier manuals for de tailed instruction s regarding the care of those devices. Daily Disconnect the air tubing and hang it in a clean, dry pla ce until next use. Weekly 1 Re ...

  • ResMed ST - page 15

    12 ! WARNING • Do not wash the air filt er . The air filter is not washable or reusab le. • The air filter cover protec ts the devi ce in the event of accidental liquid spillage onto the devic e. Ensure the air filter and air filt er cover are fit ted at all times. Servicing This product should be inspe cted by an authorized Res Med service cen ...

  • ResMed ST - page 16

    13 T roubleshooting English Troubleshooting If there is a pro blem, try the fol lowing suggestions. If the problem cannot be solved , contact your equipment supplier or Re sMed. Do not attempt to open the devi ce. No display Insufficient air delivered from the VP AP dev ice Device doe s not star t when y ou br eathe into the mask Device does not st ...

  • ResMed ST - page 17

    14 Displays err or message: Check tube!! Key if done Displays err or message: Exxxx Call Service (wher e xxxx defines an err or) Displays err or message: HIGH LEAK!!! Adjust Mask The follow ing message is display ed on the LCD after y ou try to update set tings or copy data to the D ata Card : Card Error Remove Card The follow ing message is displa ...

  • ResMed ST - page 18

    15 T echnical Specifications English Technical Specifications Note: The manufacturer reser ves the right to change these specif ications without no tice. Symbols Which Appear On The Device At tention, consult accompany ing document s; Drip proof; T ype CF equipment; Dangerous voltage; Class II equipment; Start/Stop; Manufacturer . Operating pressur ...

  • ResMed ST - page 19

    16 General Warnings and Cautions ! Warnings • Advice contained in this manual should not supersede instructions given b y the prescribing physician. • A patient should not connect a device to the data com municati on port unless instructed to do so b y their health care prov ider or phys ician. Only ResMed products are designed to be connected ...

  • ResMed ST - page 20

    17 General W arnings and Cautions English Guidance and Manufactur er ’ s Declaration – Elect romagnetic Emissions and Immun ity Guidance and manufact urer’ s declaration – electromagnetic emissions The V P AP Aut o 25 , VPAP ST and VP AP S device s are intended for use in the electroma gnetic env ironment specif ied below . The customer or ...

  • ResMed ST - page 21

    18 Guidance and manu f acturer’ s de claration – electromagnetic immunity The VP AP device is intended f or use in the electromagn etic envi ronment specifi ed below . The cus tomer or the user of the VP AP devic e should assur e that the de vice is used in suc h an en vironment. Immunity test IE C 6 0 6 01- 1- 2 t e s t level Compliance level ...

  • ResMed ST - page 22

    19 Limited W arranty English Limited Warranty ResMed warrants that your ResMed product shall be free from defects in material and workmanship for the period speci fied below from the d ate of purchase by the initial co nsumer. Th is wa rranty is not transf erable. Note: Some model s are not available in all re gions. If the product fails under cond ...

Fabbricante ResMed Categoria Oxygen Equipment

I documenti che otteniamo dal fabbricante del dispositivoResMed ST possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici ResMed
- manuali per l’uso ST
- schede prodotto ResMed
- opuscoli
- o etichette energetiche ResMed ST
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso ResMed ST.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione ResMed ST, manuali di manutenzione, brevi manuali o manuali utente ResMed ST. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto ResMed ST.

Manuali per l’uso simili

Manuale completo del dispositivo ResMed ST, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare ResMed ST dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti ResMed ST.

Il manuale per l’uso completo ResMed, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale ResMed ST - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice ResMed ST, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per ResMed ST che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo ResMed ST - che ci dovrebbe aiutare nei primi passi durante l'uso ResMed ST
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del ResMed ST