Manuale per l’uso SPX Cooling Technologies 34700-2K

32 pagine 3.27 mb
Scarica

Vai alla pagina of 32

Summary
  • SPX Cooling Technologies 34700-2K - page 1

    O p e rating M a nual Model 34700-2K/17700-2K Recovery/Recycling/Recharging Unit ...

  • SPX Cooling Technologies 34700-2K - page 2

    SAFETY DEFINITIONS: Follow all WARNING , CAUTION , IMPORTANT , and NOTE messages in this manual. These messages are defined as follows: WARNING means you may risk serious personal injury or death; CAUTION means you may risk personal injury, property damage, or unit damage; IMPORTANT means you may risk unit damage; and NOTEs provide clarity and help ...

  • SPX Cooling Technologies 34700-2K - page 3

    1 34700-2K/17700-2K Cool-Tech Recovery/Recycling/Recharging Unit T able of Contents Introduction .............................................................................................. 2 Glossary of Terms ................................................................................. 2 Setup Instructions ................................... ...

  • SPX Cooling Technologies 34700-2K - page 4

    © 2001 Robinair, SPX Corporation 2 CLOSED CLOSED RECOVER RECOVER VACUUM VACUUM RECOVER RECOVER VACUUM VACUUM CLOSED CLOSED 1 1 0 0 0 0 0 0 3 3 5 5 0 0 0 0 0 0 3 3 4 4 0 0 0 0 5 5 1 1 0 0 0 0 1 1 0 0 0 0 5 5 5 5 1 1 0 0 0 0 1 1 0 0 5 5 1 1 5 5 0 0 0 0 2 2 0 0 5 5 2 2 1 1 0 0 0 0 0 0 3 3 2 2 0 0 0 0 0 0 2 2 5 5 0 0 2 2 0 0 5 5 1 1 0 0 2 2 0 0 3 3 0 ...

  • SPX Cooling Technologies 34700-2K - page 5

    3 34700-2K/17700-2K Cool-Tech Recovery/Recycling/Recharging Unit 240 240 220 220 200 200 180 180 80 80 120 120 100 100 140 140 60 60 20 20 40 40 160 160 3 3 4 4 2 2 1 1 8 8 7 7 6 6 5 5 340 340 320 320 MLS MLS 280 280 300 300 260 260 12 12 11 11 10 10 9 9 OUNCES OUNCES CLOSED CLOSED RECOVER RECOVER RECOVER RECOVER CLOSED CLOSED CLOSE CLOSE VACUUM VA ...

  • SPX Cooling Technologies 34700-2K - page 6

    © 2001 Robinair, SPX Corporation 4 KEYP AD FUNCTIONS In addition to the number keys, the keypad contains special keys that accomplish specific operating functions. Diagram of Keypad START — Begins, or resumes, a function. STOP — Terminates, or pauses, a function. RECOVER — Activates the recovery sequence. VACUUM — Activates vacuum and auto ...

  • SPX Cooling Technologies 34700-2K - page 7

    5 34700-2K/17700-2K Cool-Tech Recovery/Recycling/Recharging Unit Setup Instr uctions INITIAL SETUP CAUTION! R-134a systems have special fittings (per SAE specifications) to avoid cross-contamination with R-12 systems. Do not attempt to adapt your unit for another refrigerant — system failure will result! Read and follow all warnings at the beginn ...

  • SPX Cooling Technologies 34700-2K - page 8

    © 2001 Robinair, SPX Corporation 6 240 240 220 220 200 200 180 180 80 80 120 120 100 100 140 140 60 60 20 20 40 40 160 160 3 3 4 4 2 2 1 1 8 8 7 7 6 6 5 5 340 340 320 320 MLS MLS 280 280 300 300 260 260 12 12 11 11 10 10 9 9 OUNCES OUNCES CLOSED CLOSED RECOVER RECOVER RECOVER RECOVER CLOSED CLOSED CLOSE CLOSE VACUUM VACUUM VACUUM VACUUM CHARGE CHA ...

  • SPX Cooling Technologies 34700-2K - page 9

    7 34700-2K/17700-2K Cool-Tech Recovery/Recycling/Recharging Unit Operating Guidelines USING THE SELECTION MENU 1. Press the MENU button. The top line of the display reads SETUP MENU. 2. Use the UP and DOWN arrow keys to scroll through the menu choices displayed on the second line. The menu choices are: 1. SELECT LANGUAGE 7. VACUUM OIL TIME 2. SELEC ...

  • SPX Cooling Technologies 34700-2K - page 10

    © 2001 Robinair, SPX Corporation 8 NOTE : If using a refillable tank, install the tank upside down, and connect the fill hose to the vapor valve. 4. Press the START key, and the tank automatically refills. The unit stops when a sufficient amount of refrigerant has been transferred to the internal tank, or if the source tank is empty. Press the STO ...

  • SPX Cooling Technologies 34700-2K - page 11

    9 34700-2K/17700-2K Cool-Tech Recovery/Recycling/Recharging Unit SELECTING A UNIT (METRIC/ENGLISH) 1. Press the MENU key. Use the arrow keys to choose SELECT UNITS, and press START to begin. 2. Toggle between UNITS ENGLISH and UNITS METRIC using the arrow key. 3. Press START to save the current choice and exit. LANGUAGE SELECT The operator can choo ...

  • SPX Cooling Technologies 34700-2K - page 12

    © 2001 Robinair, SPX Corporation 10 VACUUM VACUUM RECOVER RECOVER CLOSED CLOSED CLOSED CLOSED VACUUM VACUUM RECOVER RECOVER STOP STOP R-134A R-134A in Hg in Hg VAC VAC psi psi kPa kPa bar bar OIL INJECT OIL INJECT CHARGE CHARGE 0 0 psi psi kPa kPa bar bar R-134A R-134A 0 0 4 4 5 5 3 3 0 0 0 0 5 5 2 2 0 0 0 0 0 0 4 4 0 0 0 0 0 0 0 0 5 5 3 3 START S ...

  • SPX Cooling Technologies 34700-2K - page 13

    11 34700-2K/17700-2K Cool-Tech Recovery/Recycling/Recharging Unit Operating Instructions OPERA TING TIPS Follow the SAE-J1991 recommended service procedure for the containment of R-12, and the SAE-J2210 recommended service procedure for the containment of R-134a. The recovery compressor is not a vacuum pump. The compressor pulls the A/C system to a ...

  • SPX Cooling Technologies 34700-2K - page 14

    © 2001 Robinair, SPX Corporation 12 RECOVER RECOVER VACUUM VACUUM CLOSED CLOSED RECOVER RECOVER VACUUM VACUUM CLOSED CLOSED VAC-CHARGE VAC-CHARGE ENTER ENTER R-134A R-134A R-134A R-134A in Hg in Hg VAC VAC psi psi bar bar kPa kPa psi psi bar bar kPa kPa RECOVER RECOVER CHARGE CHARGE OIL INJECT OIL INJECT 0 0 0 0 3 3 0 0 0 0 5 5 4 4 0 0 0 0 2 2 0 0 ...

  • SPX Cooling Technologies 34700-2K - page 15

    13 34700-2K/17700-2K Cool-Tech Recovery/Recycling/Recharging Unit Operating Instructions INST0699 9. When the system has recovered to a vacuum level of approximately 13 in. Hg., the compressor automatically shuts off. 10. The unit then goes into automatic oil drain, and the display reads: OIL DRAINING. Oil draining can require up to 90 seconds to c ...

  • SPX Cooling Technologies 34700-2K - page 16

    © 2001 Robinair, SPX Corporation 14 RECOVER RECOVER VACUUM VACUUM CLOSED CLOSED RECOVER RECOVER VACUUM VACUUM CLOSED CLOSED VAC-CHARGE VAC-CHARGE ENTER ENTER R-134A R-134A R-134A R-134A in Hg in Hg VAC VAC psi psi bar bar kPa kPa psi psi bar bar kPa kPa RECOVER RECOVER CHARGE CHARGE OIL INJECT OIL INJECT 0 0 0 0 3 3 0 0 0 0 5 5 4 4 0 0 0 0 2 2 0 0 ...

  • SPX Cooling Technologies 34700-2K - page 17

    15 34700-2K/17700-2K Cool-Tech Recovery/Recycling/Recharging Unit NOTE: It is not necessary to change the High side panel valve from vacuum to charge when performing the VAC-CHARGE function. 3. Press the START key to charge the default amount of refrigerant, or use the number keys to enter the desired charge weight. Then press the START key. 4. If ...

  • SPX Cooling Technologies 34700-2K - page 18

    © 2001 Robinair, SPX Corporation 16 RECOVER RECOVER VACUUM VACUUM CLOSED CLOSED RECOVER RECOVER VACUUM VACUUM CLOSED CLOSED VAC-CHARGE VAC-CHARGE ENTER ENTER R-134A R-134A R-134A R-134A in Hg in Hg VAC VAC psi psi bar bar kPa kPa psi psi bar bar kPa kPa RECOVER RECOVER CHARGE CHARGE OIL INJECT OIL INJECT 0 0 0 0 3 3 0 0 0 0 5 5 4 4 0 0 0 0 2 2 0 0 ...

  • SPX Cooling Technologies 34700-2K - page 19

    17 34700-2K/17700-2K Cool-Tech Recovery/Recycling/Recharging Unit Operating Instructions IMPORTANT! Evacuate the A/C system for at least 15 minutes for adequate moisture and contaminant removal. RECHARGING THE A/C SYSTEM W ARNING 1. Press the CHARGE button. (If an oil inject has been performed, the CHARGE key does not have to be pressed.) 2. Put th ...

  • SPX Cooling Technologies 34700-2K - page 20

    © 2001 Robinair, SPX Corporation 18 SLOW CHARGE PROCEDURE WARNING Before starting the vehicle's engine, verify that it is in PARK or NEUTRAL, with the emergency brake ON. Never run a vehicle without adequate ventilation in the work area. CAUTION! Close the high side manifold valve before starting the vehicle A/C system. 1. Close the High Side ...

  • SPX Cooling Technologies 34700-2K - page 21

    19 34700-2K/17700-2K Cool-Tech Recovery/Recycling/Recharging Unit 240 1 2 4 3 40 20 60 100 120 80 5 6 7 8 160 140 180 200 220 9 10 11 12 260 300 280 320 340 OUNCES MLS CONTROL BREAKER MAIN POWER BREAKER Filter-Drier INST0478 Location of the Filter-Drier REPLACING THE FIL TER-DRIER Order part no. 34724 for a replacement filter-drier. The filter- dri ...

  • SPX Cooling Technologies 34700-2K - page 22

    © 2001 Robinair, SPX Corporation 20 Maintenance Instr uctions CHANGING THE V ACUUM PUMP OIL For maximum vacuum pump performance, change the vacuum pump oil after every 10 hours of operation. 1. Turn on the MAIN POWER switch. 2. Press the MENU button. NOTE: Do not connect the service hoses to a vehicle. 3. Use the arrow keys to select CHANGE VACUUM ...

  • SPX Cooling Technologies 34700-2K - page 23

    21 34700-2K/17700-2K Cool-Tech Recovery/Recycling/Recharging Unit Maintenance Instr uctions IMPORTANT! Inspect the unit periodically for leaks. The manufacturer does not reimburse for lost refrigerant. CHECKING FOR LEAKS Every three months, or as specified by local or state laws, you should check the unit for leaks. 1. Turn off the MAIN POWER switc ...

  • SPX Cooling Technologies 34700-2K - page 24

    © 2001 Robinair, SPX Corporation 22 Replacement Par ts List ELECTRICAL PROTECTION The unit is equipped with two circuit breakers. If either circuit breaker trips, the unit will not function correctly and may lose all power. Press the circuit breaker button to reset. The circuit breakers are on the back of the unit. GENERAL MAINTENANCE 1. On a regu ...

  • SPX Cooling Technologies 34700-2K - page 25

    23 34700-2K/17700-2K Cool-Tech Recovery/Recycling/Recharging Unit 34700-2K 17700-2K R-134a R-12 Replacement Replacement Component Part Number Part Number 96" Red Hose 63096 68396A 96" Blue Hose 62096 68296A Fan RA17416 RA17416 Filter-Drier 34724 34724 Compressor RA19458 RA19458 Vacuum Pump RA15425 RA15425 High Pressure Switch RA19427 RA19 ...

  • SPX Cooling Technologies 34700-2K - page 26

    © 2001 Robinair, SPX Corporation 24 Flow Diagram INST0576 1. Low Side Manifold Gauge 2. High Side Manifold Gauge 3. Low Side Manifold Valve 4. High Side Coupler 5. Oil Injector Check Valve 6. Vacuum Pump 7. Expansion Valve 8. Upper Block 9. Compressor 10. Air Purge Control 11. Lower Block 12. Return Oil Separator 13. Accumulator 14. Filter-Drier 1 ...

  • SPX Cooling Technologies 34700-2K - page 27

    25 34700-2K/17700-2K Cool-Tech Recovery/Recycling/Recharging Unit Wiring Diagram ...

  • SPX Cooling Technologies 34700-2K - page 28

    © 2001 Robinair, SPX Corporation 26 Robinair Limited W arranty Statement Rev. July 11, 2003 This product is warranted to be free from defects in workmanship, materials, and components for a period of one year from date of purchase. All parts and labor required to repair defective products covered under the warranty will be at no charge. The follow ...

  • SPX Cooling Technologies 34700-2K - page 29

    27 34700-2K/17700-2K Cool-Tech Recovery/Recycling/Recharging Unit Notes ...

  • SPX Cooling Technologies 34700-2K - page 30

    © 2001 Robinair, SPX Corporation 28 Notes ...

  • SPX Cooling Technologies 34700-2K - page 31

    ...

  • SPX Cooling Technologies 34700-2K - page 32

    124080 (Rev. C, 7-09-03) 347002K/177002K Cool-Tech © SPX Corporation Visit our web site at www.robinair.com or Call our T oll-Free T echnical Support Line at 800-822-5561 in the continental U.S. or Canada. In all other locations, contact your local distributor. To help us serve you better, please be prepared to provide the model number, serial num ...

Fabbricante SPX Cooling Technologies Categoria Cable Box

I documenti che otteniamo dal fabbricante del dispositivoSPX Cooling Technologies 34700-2K possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici SPX Cooling Technologies
- manuali per l’uso 34700-2K
- schede prodotto SPX Cooling Technologies
- opuscoli
- o etichette energetiche SPX Cooling Technologies 34700-2K
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso SPX Cooling Technologies 34700-2K.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione SPX Cooling Technologies 34700-2K, manuali di manutenzione, brevi manuali o manuali utente SPX Cooling Technologies 34700-2K. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto SPX Cooling Technologies 34700-2K.

Manuale completo del dispositivo SPX Cooling Technologies 34700-2K, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare SPX Cooling Technologies 34700-2K dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti SPX Cooling Technologies 34700-2K.

Il manuale per l’uso completo SPX Cooling Technologies, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale SPX Cooling Technologies 34700-2K - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice SPX Cooling Technologies 34700-2K, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per SPX Cooling Technologies 34700-2K che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo SPX Cooling Technologies 34700-2K - che ci dovrebbe aiutare nei primi passi durante l'uso SPX Cooling Technologies 34700-2K
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del SPX Cooling Technologies 34700-2K
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio SPX Cooling Technologies 34700-2K in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su SPX Cooling Technologies 34700-2K?

Utilizza il modulo sottostante

Se non hai risolto il problema con SPX Cooling Technologies 34700-2K con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con SPX Cooling Technologies 34700-2K è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)