    BUNN-O-MA TIC CORPORA TION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 PHONE: (217) 529-6601 FAX: (217) 529-6644 www .bunnomatic.com OPERA TING & SER VICE MANUAL CEZ, CEZF , CDBC, CDBCF Airpot, Thermal Carafe & Thermal Ser ver Brewers 29253.0000F 02/04 ©1999 Bunn-O-Matic Corporation BUNN M A N U F A C T U R E D B Y B U N N -O -M ...

  • Bunn CDBCF Airpot - page 2

    Page 2 INTRODUCTION This equipment will automatically brew a half-gallon batch of coffee into an awaiting server at the press of a button. A hot water faucet may be included for allied beverage use. Most functions of the brewer are digitally controlled. It is only for indoor use on a sturdy counter or shelf. CONTENTS Introduction & W arranty .. ...

  • Bunn CDBCF Airpot - page 3

    Page 3 USER NOTICES Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should be kept in good condition. Replace any unreadable or damaged labels. # 00986.0000 # 00656.0000 # 00658.0000 # 10044.0000 29253 011900 ...

  • Bunn CDBCF Airpot - page 4

    Page 4 ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up. Model 15 has an attached cordset and requires 2-wire grounded service rated 120 volts ac, 15 amp, single phase, 60 Hz. Model 35 requires 3-wire, grounded service rated 120/208 or 120/240 volts ac, 20 amp, single phase, 6 ...

  • Bunn CDBCF Airpot - page 5

    Page 5 OPERA TING CONTROLS Model CEZ-APS/TS/TSR ON/OFF SWITCH Placing the "ON/OFF" switch in the "ON" upper position enables the brew circuit, and energizes the tank refill circuit. Placing the switch in the "OFF" lower position stops tank refilling and brewing. Stop- ping a brew cycle after it has been started will no ...

  • Bunn CDBCF Airpot - page 6

    Page 6 INITIAL SET -UP 1. Insert an empty funnel into the funnel rails. 2. Place an empty server under the funnel. 3. Connect the brewer to the power source. 4. Model CDBC-APS/TC/TS/TSR – Press the "ON/OFF" switch (indicator glowing). Model CEZ-APS/TS/TSR – Place the "ON/OFF" switch in the "ON" upper position. 5. W ...

  • Bunn CDBCF Airpot - page 7

    Page 7 CEZ-APS/TS/TSR ADJUSTMENTS & OPTIONAL SETTINGS ...

  • Bunn CDBCF Airpot - page 8

    Page 8 CDBC-APS/TC/TS/TSR ADJUSTMENTS & OPTIONAL SETTINGS Setting Brew Temperature The brewer is factory set to brew at 200 ° F(95 ° C). To change this setting, press and hold the "HIDDEN" switch beneath the "®". The word "TEMP" above the "ON/OFF" switch will glow to correspond with the temporary funct ...

  • Bunn CDBCF Airpot - page 9

    Page 9 CDBC-APS/TC/TS/TSR ADJUSTMENTS & OPTIONAL SETTINGS (cont) W ater Sensing Threshold Adjustment Procedure 1. Make sure the tank is full of water to be used for calibration. The water must be in contact with the refill probe. 2. Unplug the brewer from the power source, then press and hold the BREW button while power is reapplied. 3. Continu ...

  • Bunn CDBCF Airpot - page 10

    Page 10 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department. • Inspection, testing, and repair of electrical equipment should be performed only b ...

  • Bunn CDBCF Airpot - page 11

    Page 11 Will not fill or refill Fill or refill does not shut "OFF" (ON/OFF Switch "ON") PROBABLE CAUSE REMEDY PROBLEM 1. Power off to brewer (CDBC-APS/ TC/TS/TSR & CEZ-APS/TS/TSR) 2. Water shut off (CDBC-APS/TC/ TS/TSR & CEZ-APS/TS/TSR) 3. Display flashing (CDBC-APS/TC/ TS/TSR) or ready light flashing (CEZ-APS/TS/TSR) 4. ...

  • Bunn CDBCF Airpot - page 12

    Page 12 TROUBLESHOOTING (cont.) Fill or refill does not shut "OFF" (ON/ OFF Switch "ON") (cont) Fill or refill does not shut "OFF" (ON/ OFF Switch "OFF") PROBABLE CAUSE REMEDY PROBLEM 2a. Water Level Probe Sensing System (CDBC-APS/TS/TSR) 2b. Water Level Probe Sensing Sys- tem (CEZ-APS/TC/TS/TSR) 3. Refill va ...

  • Bunn CDBCF Airpot - page 13

    Page 13 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY HEATING CIRCUIT 1. Display flashing (CDBC-APS/TC/ TS/TSR) or ready light flashing (CEZ-APS/TS/TSR) 2. Water not touching temperature probe 3a. Dry Plug In Probe Sensing Sys- tem (CDBC-APS/TC/TS/TSR) 3b. Dry Plug In Probe Sensing Sys- tem (CEZ-APS/TS/TSR) Brewer has shut down due to malfu ...

  • Bunn CDBCF Airpot - page 14

    Page 14 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY Water does not heat to proper temperature (cont.) IMPORTANT: Make sure no tem- perature tests are taken before the ready light is "ON". Tank tempera- ture must be stabilized before read- ings are taken. Spitting or excessive steaming 4a. Temperature Probe (CDBC-APS/ TC/TS/TSR) ...

  • Bunn CDBCF Airpot - page 15

    Page 15 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY Spitting or excessive steaming (cont.) Brewer is making unusual noises 2a. Temperature Probe (CDBC-APS/ TC/TS/TSR) 2b. Temperature Probe (CEZ-APS/ TS/TSR) 3. Control Board (CDBC & CEZ) 1. Plumbing lines 2. Water supply 3. Lime build up A) Remove the probe from the grom- met and subme ...

  • Bunn CDBCF Airpot - page 16

    Page 16 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY BREWING CIRCUIT Brew cycle will not start 1. Display flashing (CDBC-APS/TC/ TS/TSR) or ready light flashing (CEZ-APS/TS/TSR) 2. No water 3. No power or incorrect voltage to the brewer 4. ON/OFF switch not in the "ON" position 5. Low water temperature (Brew lockout is enabled) 6 ...

  • Bunn CDBCF Airpot - page 17

    Page 17 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY BREWING CIRCUIT (cont.) If the start switch (CEZ-APS/TS/ TSR) or switch panel (CDBC-APS/ TC/TS/TSR) is operating properly, proceed as follows. Attach a volt- meter to the terminals of the dis- pense valve solenoid. Connect the brewer to the power source. Turn on the brewer and press the ...

  • Bunn CDBCF Airpot - page 18

    Page 18 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY BREWING CIRCUIT (cont.) Dripping from sprayhead Weak beverage 1. Lime build up 2. Dispense valve 1. Sprayhead 2. Water temperature 3. Filter type 4. Coffee grind 5. Funnel loading Inspect the tank assembly for ex- cessive lime deposits. Delime as required. Remove the dispense valve and c ...

  • Bunn CDBCF Airpot - page 19

    Page 19 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY BREWING CIRCUIT (cont.) Dry coffee grounds remain in the funnel 1. Sprayhead 2. Funnel loading Make sure sprayhead is present and holes are clear and unobstructed. There should be separate streams of water coming out of each hole in the sprayhead. The BUNN ® paper filter must be centere ...

  • Bunn CDBCF Airpot - page 20

    Page 20 DIAGNOSTICS Intermittent flashing of the READY indicator (Model CEZ) or the bank of temperature indicators (Model CDBC) indicates that a fault exists. Count the number of flashes between pauses and use this chart as a guide to investigating the fault. FLASHES CAUSE THINGS TO CHECK 1 Dry Plug - In Fault - Water Pressure Sheath of temperature ...

  • Bunn CDBCF Airpot - page 21

    Page 21 BUNN M AN UFA CTU RE D B Y BU NN-O -M AT IC C OR POR ATIO N SPR INGF IE LD, I LLINO IS , U.S .A . M OD EL S/ N V OLTS A .C. AMP W AT TS PH ASE W IRE HE RTZ COV ERE D UN DER O NE O R MORE OF TH E FO L LO W ING PA TENT S : ON E OR M ORE OTH ER P ATE NTS M AY B E PE NDI NG D IS C O N N E C T F R O M P O W E R S O U R C E B EF O R E R E M O V A ...

  • Bunn CDBCF Airpot - page 22

    Page 22 BUNN M A N U F A C T U R E D B Y B U N N - O - M A T I C C O R P O R A T I O N S P R IN G F I E L D , I L L IN O IS 894 589.253 c128.894 588.855 129.173 588.694 129.517 588.893 ch129.217 588.8S A M O D E L52 613.249 -5 ch129.217 580.6669 -0.0001 /j0.2779 -0.0001 129.5TD(N)2 5220.85 6048129.5V278 -0.0001 TD(C)Tj0.7 ...

  • Bunn CDBCF Airpot - page 23

    Page 23 ...

  • Bunn CDBCF Airpot - page 24

    Page 24 ...

  • Bunn CDBCF Airpot - page 25

    Page 25 BUNN MANUFACTURED BY BUNN-O-MATIC CORPORATION SPRINGFIELD, ILLINOIS, U.S.A. MODEL S/N VOLTS A.C. AMP WATTS PHASE WIRE HERTZ COVERED UNDE R ONE OR MOREOF THE FOLLOWING PATENTS : ONE OR M ORE OTHER PATENTS MAY BE PENDING DISCONNECT FROM POWER SOURCE BEFORE REMOVAL OF ANY PANEL OR REPLACEMENT OF ANY COMPONENT! WARNING ! CAUTION : WARMERS AND S ...

  • Bunn CDBCF Airpot - page 26

    Page 26 BUNN MANUFACTURED BY BUNN-O-MATIC CORPORATION SPRINGFIELD, ILLINOIS, U.S.A. MODEL S/N VOLTS A.C. AMP WATTS PHASE WIRE HERTZ COVERED UNDER ONE OR MOREOF THE FOLLOWING PATENTS : ONE OR MORE OTHER PATENTS MAY BE PENDING DISCONNECT FROM POWER SOURCE BEFORE REMOVAL OF ANY PANEL OR REPLACEMENT OF ANY COMPONENT! WARNING ! CAUTION : WARMERS AND SUR ...

  • Bunn CDBCF Airpot - page 27

    Page 27 BUNN M A NU FA CT URE D BY B UNN -O -M AT IC C O R PO R A T ION SP RIN G FIELD , IL L IN OIS , U .S .A. MO DEL S /N V OL T S A.C . AM P WA TT S P HA SE W IR E HE RT Z CO V ERE D U N DE R O NE O R M O R E OF T HE FOL L O WIN G P AT E NT S : ON E O R M O RE O TH ER PAT EN TS M A Y B E PE NDIN G ...

  • Bunn CDBCF Airpot - page 28

    Page 28 BUNN M A N U F A C T U R E D B Y B U N N - O - M A T I C C O R P O R A T I O N S P R I N G F I E L D , I L L I N O I S , U . S . A . M O D E L S / N V O L T S A . C . A M P W A T T S P H A S E W I R E H E R T Z C O V E R E D U N D E R O N E O R M O R E O F T H E F O L L O W I N G P A T E N T S : O N E O R M O R E O T H E R P A T E N T S M A ...

  • Bunn CDBCF Airpot - page 29

    Page 29 Location: The tank heater is located inside the tank and secured to the tank bottom. Test Procedures: 1. Disconnect the brewer from the power supply. 2. With a voltmeter, check the voltage across the white or red wire from the terminal block and the black wire from the control board. Connect the brewer to the power source. The indication mu ...

  • Bunn CDBCF Airpot - page 30

    Page 30 P1856 SERVICE (cont.) TANK HEATER (Cont.) BLK to Control Board WHI or RED to Terminal Block FIG. 14 TANK HEATER WIRING 17. Install tank assembly onto mounting brackets and secure in place with four #8-32 nuts. 18. Install tank lid and secure in place with eight #8-32 nuts. 19. Connect the two white wires of the tank warmer blanket. 20. Conn ...

  • Bunn CDBCF Airpot - page 31

    Page 31 T RM 2 J1 J2 J3 J4 J5 J6 J7 TR M1 CAUTION : WARMERS AND SURFACES ARE HOT SERVICE (cont.) REFILL VALVE Location: The refill valve is located inside the trunk on the lower center part of the component bracket. Test Procedures: 1. Disconnect the brewer from the power source. 2. Disconnect the white and white/blue wires from the refill valve. S ...

  • Bunn CDBCF Airpot - page 32

    Page 32 SCHEMA TIC WIRING DIAGRAM CDBC-APS/TS/TSR 29253 111103 EARL Y MODELS SOL 29257.0000B 12/99 ©1998 BUNN-O-MATIC CORPORATION TANK HEATER L1 GRN GRN RED-14 (MODEL 35) WHI-14 (MODELS 15 & 20) N L2 BLU-14 BLU-14 "KEEP WARM" HEATER WHI WHI LIMIT THERMOSTAT WHI WHI WHI WHI SOL REFILL DISPENSE J1-1 J1-2 J1-1 J1-5 J1-10 C O N T R O L P ...

  • Bunn CDBCF Airpot - page 33

    Page 33 SCHEMA TIC WIRING DIAGRAM CEZ-APS/TS/TSR WHI 29341.0000B 6/99 ©1998 BUNN-O-MATIC CORPORATION WHI WHI BREW SWITCH TANK HEATER GRN RED-14 (MODEL 35) WHI-14 (MODELS 15 & 20) N L2 BLU-14 "KEEP WARM" HEATER WHI SOL REFILL SOL DISPENSE TRM-1 TRM-2 J7-1 J7-2 J1-1 J1-8 J5-1 J5-6 C O N T R O L B O A R D COM N.O. BLK BLK-14 BLK-14 BLK ...

  • Bunn CDBCF Airpot - page 34

    Page 34 LA TE MODELS 29253 021604 SOL SCHEMATIC WIRING DIAGRAM CDBC 15, 20 & 35 APS/TC/TS 29257.0001D 02/04 ©1999 BUNN-O-MATIC CORPORATION TANK HEATER L1 GRN RED-14 (MODEL 35) WHI-14 (MODELS 15 & 20) N L2 BLU-14 BLU-14 "KEEP WARM" HEATER WHI LIMIT THERMOSTAT WHI WHI WHI WHI SOL REFILL DISPENSE J1-1 J1-2 J1-1 J1-5 J1-10 C O N T R ...

Fabbricante Bunn Categoria Coffeemaker

I documenti che otteniamo dal fabbricante del dispositivoBunn CDBCF Airpot possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Bunn
- manuali per l’uso CDBCF Airpot
- schede prodotto Bunn
- opuscoli
- o etichette energetiche Bunn CDBCF Airpot
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Bunn CDBCF Airpot.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Bunn CDBCF Airpot, manuali di manutenzione, brevi manuali o manuali utente Bunn CDBCF Airpot. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Bunn CDBCF Airpot.

Manuali per l’uso simili

Manuale completo del dispositivo Bunn CDBCF Airpot, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Bunn CDBCF Airpot dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Bunn CDBCF Airpot.

Il manuale per l’uso completo Bunn, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Bunn CDBCF Airpot - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Bunn CDBCF Airpot, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Bunn CDBCF Airpot che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Bunn CDBCF Airpot - che ci dovrebbe aiutare nei primi passi durante l'uso Bunn CDBCF Airpot
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Bunn CDBCF Airpot
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Bunn CDBCF Airpot in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Bunn CDBCF Airpot?

Utilizza il modulo sottostante

Se non hai risolto il problema con Bunn CDBCF Airpot con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Bunn CDBCF Airpot è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)