    Gas-Fir ed V ented Room Heater INST ALLA TION AND OPERA TING INSTRUCTIONS P/N 80900-H - REV . 01/05 This appliance is equipped with a safety control system designed to protect against improper venting of combustion products. THIS UNIT IS NOT TO BE INST ALLED IN MOBILE HOMES. W ARNING: If the information in this manual is not followed exactly , a fi ...

  • Louisville Tin and Stove VC201A-H - page 2

    SPECIFICA TIONS………………………. 2 INTRODUCTION……………………….. 3 VENTING………………………………... 3 , 4 GAS SUPPL Y……………………………. 5 LOCA TION & SPECIAL PRECAUTIONS 5 COMBUSTION & VENTILA TION AIR.... 6 CLEARANCES………………………….. 7 DRAFT DIVER TER………………… ...

  • Louisville Tin and Stove VC201A-H - page 3

    INTRODUCTION THIS IS A GAS-FIRED, GRA VITY VENTED ROOM HEA TER THA T WILL OPERA TE SAFEL Y AND PROVIDE AN EFFICIENT SOURCE OF HEA T WHEN INST ALLED, OPERA TED AND MAINT AINED AS RECOMMENDED IN THESE INST ALLA TION AND OPERA TING INSTRUCTIONS. READ THESE INSTRCTIONS THOROUGHL Y BEFORE INST ALLING, SER VICING, OR USING THIS APPLIANCE. IF YOU DO NOT U ...

  • Louisville Tin and Stove VC201A-H - page 4

    VENTING 10’ or Less 2’ Min. 3’ Min. Ridge Chimney More than 10’ 10’ 2’ Min. 3’ Min. Ridge Chimney Height above any roof surface withon 10’ horizontally FIGURE A FIGURE A Seal around collar & flashings Maintain 1” Clearance Support Laterals T ermination of vent must be securely guyed or braced if it extends more than five (5) f ...

  • Louisville Tin and Stove VC201A-H - page 5

    GAS SUPPL Y This vented room heater must be connected to a gas supply capable of supplying the appliances full rated capacity . Provide a 1/8 inch N.P .T . plugged tapping, accessible for test gauge connection, immediately upstream of the gas supply connection to the appliance. The minimum inlet pressure in the gas supply pipe should be 4.5” w .c ...

  • Louisville Tin and Stove VC201A-H - page 6

    COMBUSTION AND VENTILA TION AIR When installed, this gas appliance must be provided with fresh air for combustion, ventilation, and dilution of hot flue gases. The minimum required volume of the area where the appliance is installed should be 50 cubic feet per 1,000 btu/hr . If installed in an area of the home that is considered an unconfined space ...

  • Louisville Tin and Stove VC201A-H - page 7

    CLEARANCES If the area where the appliance is to be installed contains carpeting, tile, or combustible materials, other than wood flooring, the appliance shall be installed on a metal plate (stoveboard), a wood panel, or other non-combustible materials. The use of ceramic or quarry tile is acceptable and provides an appealing surface that is easily ...

  • Louisville Tin and Stove VC201A-H - page 8

    PILOT ADJUSTMENT The pilot flame can be observed by opening the pilot lighting hole cover . The pilot flame should surround the top 3/8 to ½ inch of the thermocouple (see Figure 2). If the flame needs adjusting, first locate the pilot adjustment screw cap and remove. Adjustment screw is underneath (see Figure 1). T o increase the flame, turn the p ...

  • Louisville Tin and Stove VC201A-H - page 9

    CAUTION: There may be momentary and spasmodic orange flashes in the flame. This is caused by the burning of air borne dust particles and is not to be confused with the yellow tipping which is a stable or permanent situation when there is insufficient primary air . MAINTENANCE CLEANING : T o clean the front casing of your heater , it is only necessa ...

  • Louisville Tin and Stove VC201A-H - page 10

    10. Close pilot lighting hole cover and casing door . 11. Turn gas control knob counterclockwise to “ON”. 12. Turn temperature control knob to desired setting. MODELS: VC201A-H, VC202A-H, VC351A-H, VC352A-H, VC501A-H, VC502A-H, VC701A-H, VC702A-H, VCR351A-H, VCR352A-H, VCR501A-H, VCR502A-H, VCR701A-H, VCR702A-H FOR YOUR SAFETY READ BEFORE LIGHT ...

  • Louisville Tin and Stove VC201A-H - page 11

    Flame too large 1. Defective operator section of gas valve. 1. Replace complete valve. 2. Burner orifice too large. 2. See orifice chart to determine the correct orifice size for your Model Number and elevation. 3. Pressure regulator malfunction. 3. Regulator must be adjusted by a qualified serviceman using proper tools and instruments. Noisy Flame ...

  • Louisville Tin and Stove VC201A-H - page 12

    Not enough heat 1. Heater undersized. 1. This is especially true when a dwelling or room is enlarged. Have the heat loss calculated and compare to the heater output (70% of input). Y our gas company or installer can supply you with this information. If heater is undersized, replace with correct size unit. 2. T emperature dial set too low . 2. Raise ...

  • Louisville Tin and Stove VC201A-H - page 13

    Page 13 Heat Shield Junction Box Speed Control Power Cord Fan Switch Bracket Blower Housing Mounting T ab FIGURE A CHB-3 BLOWER INST ALLA TION - (OPTIONAL) (ST ANDARD ON 70,000 BTU UNITS ONL Y) STEP 1. Run black wire and white wire that comes from bottom of junction box down through the heat shield. See Figure A. STEP 2. Insert junction box into op ...

  • Louisville Tin and Stove VC201A-H - page 14

    TSK W ALL ST A T KIT OPTIONAL (VC/VCR- H SERIES HEA TERS) W ALL THERMOST A T INST ALLA TION INSTRUCTIONS Y our heater can be re-wired to operate with a millivolt wall thermostat by your installer . See wiring diagram below for correct wiring. NOTE: Do not disconnect the wire from the blocked flue switch to the “TH” terminal on the gas valve. ST ...

  • Louisville Tin and Stove VC201A-H - page 15

    MODELS INCLUDED: VC-H / Closed Front Circulators VCR-H / Radiant Front Circulators CHB3 Blower VENTED CONSOLE HEA TER Prices and specifications subject to change without notice. All prices are F .O.B. factory . NOTICE: When ordering any component in the control train assembly , specify either Honeywell or Robertshaw components. Page 15 50 43 51 47 ...

  • Louisville Tin and Stove VC201A-H - page 16

    NA T . VC201A-H VC / VCR351A-H VC / VC R501A-H VC / VCR701A-H MODEL NUMBER L. P . VC202A-H VC / VCR352A-H VC / VC R502A-H VC / VCR702A-H REF . P A RT LIST P A RT LIST P AR T LIST P A R T LIST P ART DESCRIPTION NO. NO. PRICE NO. PRICE NO. PRICE NO. PRICE V alve, VS821A1061 Honeywell, Nat. Gas 1 7 43 15 $164.30 74315 $164.30 74315 $164.30 74315 $164. ...

  • Louisville Tin and Stove VC201A-H - page 17

    IMPOR T ANT SAFETY BULLETIN ON YOUR GAS CONTROL AND PILOT LIGHT SYSTEM FOR HEA TING EQUIPMENT WHA T YOU DON’T KNOW CAN HUR T YOU. Y our pilot light system has been designed for safe and reliable operation. Although safety mechanisms are built-in, the potential for hazard exists. This information is intended to help you avoid these hazards. YOUR G ...

  • Louisville Tin and Stove VC201A-H - page 18

    The Louisville Tin & Stove Co. warrants to the original user the accompanying product for the period specified herein, provided said product is installed, operated, maintained, serviced, and used according to the instructions and specifications accompanying the product. AS OUTLINED IN OUR INSTRUCTIONS, ANY W ARRANTY CONSIDERA TIONS ARE CONTINGE ...

Fabbricante Louisville Tin and Stove Categoria Electric Heater

I documenti che otteniamo dal fabbricante del dispositivoLouisville Tin and Stove VC201A-H possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Louisville Tin and Stove
- manuali per l’uso VC201A-H
- schede prodotto Louisville Tin and Stove
- opuscoli
- o etichette energetiche Louisville Tin and Stove VC201A-H
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Louisville Tin and Stove VC201A-H.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Louisville Tin and Stove VC201A-H, manuali di manutenzione, brevi manuali o manuali utente Louisville Tin and Stove VC201A-H. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Louisville Tin and Stove VC201A-H.

Manuale completo del dispositivo Louisville Tin and Stove VC201A-H, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Louisville Tin and Stove VC201A-H dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Louisville Tin and Stove VC201A-H.

Il manuale per l’uso completo Louisville Tin and Stove, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Louisville Tin and Stove VC201A-H - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Louisville Tin and Stove VC201A-H, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Louisville Tin and Stove VC201A-H che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Louisville Tin and Stove VC201A-H - che ci dovrebbe aiutare nei primi passi durante l'uso Louisville Tin and Stove VC201A-H
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Louisville Tin and Stove VC201A-H
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Louisville Tin and Stove VC201A-H in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Louisville Tin and Stove VC201A-H?

Utilizza il modulo sottostante

Se non hai risolto il problema con Louisville Tin and Stove VC201A-H con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Louisville Tin and Stove VC201A-H è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)