    PROP ANE CONSTRUCTION HEA TER USER’S INSTRUCTION MANUAL RMC-F A40DLX (40,000 BTU/HR, FORCED - AIR) RMC-F A100DLX (70,000/100,000 BTU/HR, FORCED - AIR) RMC-F A150DLX (120,000/150,000 BTU/HR, FORCED - AIR) RMC-F A40A (40,000 BTU/HR, FORCED - AIR) RMC-F A50A (30,000/50,000 BTU/HR, FORCED - AIR) RMC-F A100A (70,000/100,000 BTU/HR, FORCED - AIR) RMC-F ...

  • Vermont Casting CSA 2.14-2000 - page 2

    Page 1 T ABLE OF CONTENTS • Introduction & Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 • General Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 • Product Features . . . . . . . . . . . . . . . . . . . . . . . ...

  • Vermont Casting CSA 2.14-2000 - page 3

    Page 2 F W ARNING: Not for use with ductwork. SPECIFICA TIONS: Dyna-Glo Pr opane For ced Air Construction Heaters The heater is designed and approved for use as a construction heater under ANSI Z83.7., CSA2.14 It is hard to anticipate every use which may be made of this heater . CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HA VE QUESTIONS ABO ...

  • Vermont Casting CSA 2.14-2000 - page 4

    Page 3 GENERAL SAFETY INSTRUCTIONS: Accidents are always tragic especially because so many of them could have been prevented with lit- tle care and judgment. There are some basic good practices, we hope you will follow for safe use of your heater . IMPOR T ANT SAFETY INFORMA TION: • Children should be carefully supervised, when they are in the ar ...

  • Vermont Casting CSA 2.14-2000 - page 5

    Page 4 UNP ACKING: 1. Remove heater from carton. 2. Remove all protective packing applied to heater for shipment. 3. Retain cartons and packaging material until unit is operated and found in good condition. 4. Checker heater for any shipping damage. If heater shows any external or internal damage, promptly inform dealer/distributor where you purcha ...

  • Vermont Casting CSA 2.14-2000 - page 6

    Page 5 INST ALLA TION T O THE PROP ANE GAS T ANK: IMPOR T ANT : Y ou must use a propane/LP gas supply cylinder that is compatible with the connec- tion device provided with the hose and regulator . 1. Provide propane/LP supply system (see Propane/LP Supply , page 6). 2. Connect fuel gas fitting hose/regulator assembly to propane LP tank(s). T urn f ...

  • Vermont Casting CSA 2.14-2000 - page 7

    Page 6 Propane is safe to use when properly handled. Careless handling of the Propane gas tank could result in fire and/or an explosion. Therefore: • Always keep tank/cylinder securely fastened in an upright position. • A void tipping tank on its side when connected to a regulator since this may cause damage to diaphragm in regulator . • Hand ...

  • Vermont Casting CSA 2.14-2000 - page 8

    Page 7 SHUTDOWN INSTRUCTIONS: Shutoff Heater: W ARNING: Motor and fan must be running before lighting, during operation and at shutdown, in order to prevent a flame-out condition which could result in personal injury or property damage. T urn gas valve knob clockwise to OFF position. T urn gas supply OFF by turning Propane tank valve clockwise to c ...

  • Vermont Casting CSA 2.14-2000 - page 9

    Page 8 PROP ANE CONSTRUCTION HEA TER ILLUSTRA TED 40,000 BTU/Hr - 50,000 BTU/Hr ...

  • Vermont Casting CSA 2.14-2000 - page 10

    Page 9 ITEM NO. DESCRIPTION QTY . P AR T NUMBER REMARK RMC-F A40DLX/ RMC-F A40A/RMC-F A50A 1 OUT SHELL 1 CFM40.01 2 HANDEL ASSEMBL Y 1 CFM40.10 3 SCREW 2 M5X10 4 MOTOR ASSEMBL Y 1 CFM40.09-02 4-1 FA N 1 CFM40.05-01 5 SCREW 4 ST3.9X8 6 SUPPOR T MOTOR 1 CFM40.06-02 7 SUPPOR T MOTOR SCREW 2 M6X15 8 MOTOR BRACKET 1 CFM40.06-01 9 MOTOR CONDENSER 1 CFM50 ...

  • Vermont Casting CSA 2.14-2000 - page 11

    Page 10 PROP ANE CONSTRUCTION HEA TER ILLUSTRA TED 100,000 BTU/Hr - 150,000 BTU/Hr ...

  • Vermont Casting CSA 2.14-2000 - page 12

    Page 1 1 ILLUSTRA TED P AR TS BREAKDOWN ITEM NO. DESCRIPTION QTY . P AR T NUMBER REMARK RMC-F A100DLX/ RMC-F A100A RMC-F A150DLX/ RMC-F A150A 1 OUT SHELL 1 1A0091A 1A0091B 2 HANDEL ASSEMBL Y 1 3A0197 3A0197 3 SCREW 1 PMF 4012Y PMF 4012Y 4 NUT 1 HOT04Y HOT04Y 5 MOTOR ASSEMBL Y 1 2A0169B 2A0169B 5-1 MOT OR F AN 1 3A0199B 3A0199B 6 MOTOR SUPPOR T 1 3A ...

  • Vermont Casting CSA 2.14-2000 - page 13

    Page 12 WIRING DIAGRAMS: ...

  • Vermont Casting CSA 2.14-2000 - page 14

    W ARRANTY : SER VICE AND LIMITED W ARRANTY CFM Home Products warrants this pr oduct to be free from defects in materials and components for two (2) years from the date of first pur chase, provided that the product has been properly installed, operated and maintained in accor dance with all applicable instructions. T o make a claim under warranty th ...

Fabbricante Vermont Casting Categoria Fan

I documenti che otteniamo dal fabbricante del dispositivoVermont Casting CSA 2.14-2000 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Vermont Casting
- manuali per l’uso CSA 2.14-2000
- schede prodotto Vermont Casting
- opuscoli
- o etichette energetiche Vermont Casting CSA 2.14-2000
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Vermont Casting CSA 2.14-2000.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Vermont Casting CSA 2.14-2000, manuali di manutenzione, brevi manuali o manuali utente Vermont Casting CSA 2.14-2000. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Vermont Casting CSA 2.14-2000.

Manuali per l’uso simili

Manuale completo del dispositivo Vermont Casting CSA 2.14-2000, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Vermont Casting CSA 2.14-2000 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Vermont Casting CSA 2.14-2000.

Il manuale per l’uso completo Vermont Casting, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Vermont Casting CSA 2.14-2000 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Vermont Casting CSA 2.14-2000, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Vermont Casting CSA 2.14-2000 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Vermont Casting CSA 2.14-2000 - che ci dovrebbe aiutare nei primi passi durante l'uso Vermont Casting CSA 2.14-2000
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Vermont Casting CSA 2.14-2000
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Vermont Casting CSA 2.14-2000 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Vermont Casting CSA 2.14-2000?

Utilizza il modulo sottostante

Se non hai risolto il problema con Vermont Casting CSA 2.14-2000 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Vermont Casting CSA 2.14-2000 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)