Manuale per l’uso Carrier 38VYX130

14 pagine 0.46 mb
Scarica

Vai alla pagina of 14

Summary
  • Carrier 38VYX130 - page 1

    38VYX110/38VYX130 • L L O Y D ' S R E G I S T E R Q U A L I T Y A S S U R A N C E I S O 9 0 0 1 INST ALLA TION MANU AL ...

  • Carrier 38VYX130 - page 2

    38VYX110/38VYX130 Heat pump split system outdoor units GB - 1 ENGLISH For operation and maintenance instructions of this unit as well as installation instructions of the indoor unit, refer to the rele vant man uals. Contents P age Precautions f or safety ............................................................................................... ...

  • Carrier 38VYX130 - page 3

    GB - 2 38VYX110/38VYX130 General inf ormation Precautions f or safety The unit m ust be installed according to the national plant- engineering standards. • Read this “ PRECA UTIONS FOR SAFETY ” carefully bef ore Installation. • The precautions described below include the impor tant items regarding saf ety . Observe them without fail. • Af ...

  • Carrier 38VYX130 - page 4

    GB - 3 38VYX110/38VYX130 ENGLISH Outdoor unit Drain nipple Installation manual x 1 W ater proof rubber cap Accessory and refrig erant T ab le II: Accessory and Installation P ar ts Refrigerant Piping • Piping kit used f or the conventional refrigerant cannot be used. • Use copper pipe with 0.8 mm or more thickness f or Ø 9,52 mm. • Use coppe ...

  • Carrier 38VYX130 - page 5

    GB - 4 38VYX110/38VYX130 Knock out procedure • The indoor/outdoor connecting pipes can be connected to 4 directions. T ake off the knoc kout part of the pipe cover in which pipes or wires pass through the base plate. • As shown in the figure , do not remove the pipe co ver from the cabinet so that the knock out hole can be easily punched. T o k ...

  • Carrier 38VYX130 - page 6

    GB - 5 38VYX110/38VYX130 ENGLISH Refrigerant piping Flaring 1. Cut the pipe with a pipe cutter . 2. Inser t a flare nut into the pipe, and flare the pipe. As the flaring sizes of R410A diff er from those of refrigerant R22, the flare tools newly man ufactured f or R410A are recommended. T ab le V : Pipe outer diameter • In case of flaring for R41 ...

  • Carrier 38VYX130 - page 7

    38VYX110/38VYX130 GB - 6 Minim um clearances Single unit installation Obstac les at both right and left sides. Serial installation of two or more units Single unit installation Obstac les at both right and left sides. 1000 or more 1000 or more • The height of the obstacle should be low er than the height of the outdoor unit. • The height of the ...

  • Carrier 38VYX130 - page 8

    GB - 7 38VYX110/38VYX130 ENGLISH Minim um clearances Open the upper side and both right and left sides. The height of obstacle at both front and rear side, should be low er than the height of the outdoor unit. 1000 or more 150 or more Serial installation of two or more units 1000 or more 1500 or more 2000 or more 200 or more 300 or more Obstacles a ...

  • Carrier 38VYX130 - page 9

    GB - 8 38VYX110/38VYX130 • When there is a possibility of freezing of drain at the cold district or a snowf all area, be careful for dr ainage ability of drain. The drainage ability increases when a knock out hole on the base plate is opened. (Open the knockout hole to outside using a screwdriv er , etc.) • In case of draining through the drain ...

  • Carrier 38VYX130 - page 10

    GB - 9 38VYX110/38VYX130 ENGLISH Ev acuating Air Purge With respect to the preser vation of terrestrial environment, adopt “ V acuum pump ” for air purge (Ev acuate air in the connecting pipes) when installing the unit. • Do not discharge the refrigerant gas to the atmosphere to preser ve the terrestrial environment. • Use a vacuum pump to ...

  • Carrier 38VYX130 - page 11

    38VYX110/38VYX130 GB - 10 All field electrical connections are the responsibility of the installer . W ARNING: • Wrong wiring ma y cause a burn-out to some electr ical par ts. • Be sure to use the cord clamps attached to the product. • Do not damage or scratch the conductiv e core and inner insulator of pow er and inter-connecting cables when ...

  • Carrier 38VYX130 - page 12

    GB - 11 38VYX110/38VYX130 ENGLISH Final installation chec ks Check and T est Operation For R410A, use the leak detector e xclusively manuf actured for HFC refrigerant (R410A, R134a, etc.). • The conv entional leak detector for HCFC refrigerant (R22, etc.) cannot be used because its sensitivity for HFC refrigerant lowers to appro x. 1/40. • Pres ...

  • Carrier 38VYX130 - page 13

    38VYX110/38VYX130 GB - 12 Final installation chec ks Installation/Servicing T ools Changes in the product and components In the case of an air conditioner using R410A, in order to prev ent any other refrigerant from being charged accidentally , ser vice por t diameter of the outdoor unit control valv e (3 way v alve) has been changed. (1/2 UNF 20 t ...

  • Carrier 38VYX130 - page 14

    38VYX 110-130 Via R. Sanzio, 9 - 20058 Villasanta (MI) Italy - Tel. 039/3636.1 The manufacturer reserves the right to change an y product specifications without notice. Nov ember , 2003 Printed in Japan ...

Fabbricante Carrier Categoria Heat Pump

I documenti che otteniamo dal fabbricante del dispositivoCarrier 38VYX130 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Carrier
- manuali per l’uso 38VYX130
- schede prodotto Carrier
- opuscoli
- o etichette energetiche Carrier 38VYX130
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Carrier 38VYX130.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Carrier 38VYX130, manuali di manutenzione, brevi manuali o manuali utente Carrier 38VYX130. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Carrier 38VYX130.

Manuali per l’uso simili

Manuale completo del dispositivo Carrier 38VYX130, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Carrier 38VYX130 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Carrier 38VYX130.

Il manuale per l’uso completo Carrier, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Carrier 38VYX130 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Carrier 38VYX130, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Carrier 38VYX130 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Carrier 38VYX130 - che ci dovrebbe aiutare nei primi passi durante l'uso Carrier 38VYX130
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Carrier 38VYX130
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Carrier 38VYX130 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Carrier 38VYX130?

Utilizza il modulo sottostante

Se non hai risolto il problema con Carrier 38VYX130 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Carrier 38VYX130 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)