Manuale per l’uso Bryant SYSTXBBUIZ01

16 pagine 0.61 mb
Scarica

Vai alla pagina of 16

Summary
  • Bryant SYSTXBBUIZ01 - page 1

    NOTE: Read the entire instruction manual before starting the installation. This symbol → indicates a change since the last issue. TABLE OF CONTENTS SAFETY CONSIDERATIONS .....................................................1 INTRODUCTION ..........................................................................1 INSTALLATION AND START-UP OVERVIEW ...

  • Bryant SYSTXBBUIZ01 - page 2

    B. Step 2 — Evolution Zone Control ™ Location and Wiring Considerations WARNING: ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or possible equipment damage. Disconnect Power before routing control wiring. All wiring must comply with national, local, and state codes. EVOLUTION ™ ZONE CONTROL LOCATION ? ...

  • Bryant SYSTXBBUIZ01 - page 3

    C. Step 3 — Installing Evolution Zone Control ™ WARNING: ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death. Before installing Evolution Zone Control ™ , turn off all power to equipment. There may be more than one power source to disconnect. 1. Turn off all power to equipment. 2. If an existing Use ...

  • Bryant SYSTXBBUIZ01 - page 4

    8. Match and connect thermostat wires to proper terminals on User Interface backplate. See wiring diagram Fig. 12, 13, and 14. A — Green = Data A B — Yellow = Data B C — White = 24VAC (Com) D — Red = 24VAC (Hot) NOTE: It is not mandatory that the above color code be used, but each ABCD connection in the system MUST be wired consis- tently. ...

  • Bryant SYSTXBBUIZ01 - page 5

    isolation relay coil to furnace or fan coil HUM and COM terminals will allow the Evolution Zone Control to automatically energize the HUM output during a call for humidification. The N.O. relay contacts will be used to energize the humidifier. See fan powered humidifier installation instructions for more details. WARNING: FIRE OR EQUIPMENT HAZARD F ...

  • Bryant SYSTXBBUIZ01 - page 6

    NOTE: Range of outdoor unit Btu selection is limited by model number of indoor unit installed. The Evolution Zone Control ™ will not allow an outdoor unit size that is not supported by the installed indoor unit. NOTE: On new system installations, the model and serial number will be recognized and displayed. On any indoor/outdoor board replacement ...

  • Bryant SYSTXBBUIZ01 - page 7

    QUICK START For first time installers, Quick Start will allow a quick start up of the Evolution Zone System before learning all the details of system operation. However, for the best possible comfort and operation refer to the Evolution Zone Control ™ Owner ’ s Manual. A. Set Day, Time & Desired Humidity 1. Flip down the door at the base of ...

  • Bryant SYSTXBBUIZ01 - page 8

    EQUIPMENT SUMMARY MENU An example screen is shown in Fig. 21: This screen shows indoor unit type and model number, outdoor unit type (and model number if a 2-speed unit), filter type, any accessories that are installed, and how many zones are recognized. INSTALL MENU This menu item will perform start-up process in order to learn all equipment in sy ...

  • Bryant SYSTXBBUIZ01 - page 9

    NORMAL airflow adjustment is used during dehumidifying. If duct sweating is an issue, selecting HIGH will increase the dehumidifying airflow and reduce the sweating. LOW HEAT RISE: • ON • OFF (default) Set this to ON if the system contains a bypass humidifier. The ON setting will increase the furnace low heat airflow. STAGING: • SYSTEM (defau ...

  • Bryant SYSTXBBUIZ01 - page 10

    Interval at which the Change Humidify Pad notification will be displayed. HUMIDIFY WITH FAN: • NO (default) • YES If YES, the humidifier will run with Continuous Fan operation if there is a humidify demand. VENTILATOR: NOTE: Only appears if ventilator is installed. CLEAN INTERVAL: • 60 to 180 days of actual operation (default=90) Interval at ...

  • Bryant SYSTXBBUIZ01 - page 11

    display. The word ″ FAIL ″ will also be displayed instead of the actual temperature for Zone 2. Reconnect Zone 2 sensor and try all remaining sensors one at a time in the system. Smart Sensors may also be checked, see Smart Sensor Installation Instructions for procedure. AIRFLOW LIMITS: • Low • Medium • High (default) • Maximum Because ...

  • Bryant SYSTXBBUIZ01 - page 12

    Service = LAST 10 SYSTEM FAULTS This screen will show last 10 faults that occurred throughout the system. Each fault has the time and date incident recorded. Service technician should enter current date in ″ TODAY ’ S DATE ″ menu section BEFORE checking and logging the last 10 system faults. Each fault has a two-letter acronym preceding the f ...

  • Bryant SYSTXBBUIZ01 - page 13

    TROUBLESHOOTING Evolution Zone Control ™ does not power up. 1. Recheck wiring to ABCD on all devices. 2. Make sure all colors match for every terminal. 3. Make sure power is applied to the indoor unit, and the amber LED is lit on indoor control circuit board. 4. Check for 24VAC between the C and D terminals at Evolution Zone Control ™ terminal ...

  • Bryant SYSTXBBUIZ01 - page 14

    14 ...

  • Bryant SYSTXBBUIZ01 - page 15

    15 ...

  • Bryant SYSTXBBUIZ01 - page 16

    © 2004 Bryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231 — 16 — Printed in U.S.A. iiuiz01-0-1 Catalog No. 809-60024 ...

Fabbricante Bryant Categoria Thermostat

I documenti che otteniamo dal fabbricante del dispositivoBryant SYSTXBBUIZ01 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Bryant
- manuali per l’uso SYSTXBBUIZ01
- schede prodotto Bryant
- opuscoli
- o etichette energetiche Bryant SYSTXBBUIZ01
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Bryant SYSTXBBUIZ01.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Bryant SYSTXBBUIZ01, manuali di manutenzione, brevi manuali o manuali utente Bryant SYSTXBBUIZ01. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Bryant SYSTXBBUIZ01.

Manuali per l’uso simili

Manuale completo del dispositivo Bryant SYSTXBBUIZ01, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Bryant SYSTXBBUIZ01 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Bryant SYSTXBBUIZ01.

Il manuale per l’uso completo Bryant, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Bryant SYSTXBBUIZ01 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Bryant SYSTXBBUIZ01, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Bryant SYSTXBBUIZ01 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Bryant SYSTXBBUIZ01 - che ci dovrebbe aiutare nei primi passi durante l'uso Bryant SYSTXBBUIZ01
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Bryant SYSTXBBUIZ01
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Bryant SYSTXBBUIZ01 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Bryant SYSTXBBUIZ01?

Utilizza il modulo sottostante

Se non hai risolto il problema con Bryant SYSTXBBUIZ01 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Bryant SYSTXBBUIZ01 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)