    R EAD FIRST WHEN INSTALLING A PIM-485-16-TD-NXT Addendum INSTALLING , CONFIGURING & OPERATING PANEL INTERFACE MODULE RS485 NexSentry Star I/II Version (PIM-485-16-TD-NXT) The most current version of this docu ment is available for download at: http://www.irsupport.net IR Security & Safety 575 Birch St. (866) 322-1237 (866) 322-1233 fax P/N: ...

  • Schlage Panel Interface Module RS485 - page 2

    IR Security & Safety 575 Birch St., Forestville, Connecticut 06010 / (860) 584-9158 / (860) 584-2136 fax P/N: M053-016-A http://www.ir support.net Page 2 of 15 575 Birch St. Forestville, Ct 06010 (866) 322-1237 (866) 322-1233 Fax World Wide Web http://www.irsupport.net Copyright © 2003-2004 Ingersoll-Rand, all righ ts reserved. No part of this ...

  • Schlage Panel Interface Module RS485 - page 3

    IR Security & Safety 575 Birch St., Forestville, Connecticut 06010 / (860) 584-9158 / (860) 584-2136 fax P/N: M053-016-A http://www.ir support.net Page 3 of 15 INSTALLATION & OPERATING INSTRUCTIONS TABLE OF CONTENTS 1. Wyreless Access™ System ( WAS ).......................................................................................... ...

  • Schlage Panel Interface Module RS485 - page 4

    IR Security & Safety 575 Birch St., Forestville, Connecticut 06010 / (860) 584-9158 / (860) 584-2136 fax P/N: M053-016-A http://www.ir support.net Page 4 of 15 1. W yreless Access™ System (W AS) 1.1 Overview Every access control system that uses Wyreless Acce ss TM contains two differe nt types of modul es (Figure 1-1): • at least one Wyrel ...

  • Schlage Panel Interface Module RS485 - page 5

    IR Security & Safety 575 Birch St., Forestville, Connecticut 06010 / (860) 584-9158 / (860) 584-2136 fax P/N: M053-016-A http://www.ir support.net Page 5 of 15 1.2 Panel Interface Module-RS485-Ne xSentry (PIM-485-16-TD-NXT) The Panel Interface Module-RS485-NexSe ntry (PIM -485-16-TD-NXT) is a product in Schlage’s Wyreless Panel Interface Mo d ...

  • Schlage Panel Interface Module RS485 - page 6

    IR Security & Safety 575 Birch St., Forestville, Connecticut 06010 / (860) 584-9158 / (860) 584-2136 fax P/N: M053-016-A http://www.ir support.net Page 6 of 15 The PIM-485- 16-TD-NX T can be or dered wit h one of t hree possible e nclosures. The xx in the PIM-485- 16-TD-NXT sa les m odel number i ndicates the m axim um number of WAPM’s that c ...

  • Schlage Panel Interface Module RS485 - page 7

    IR Security & Safety 575 Birch St., Forestville, Connecticut 06010 / (860) 584-9158 / (860) 584-2136 fax P/N: M053-016-A http://www.ir support.net Page 7 of 15 MODEL ENCLOSURE MAXI MUM NUMBER OF WAPMs LOCATION ACCESS CONTROL PANEL INTERFACE/DESCRIPTION PIM-485-1 6-TD-NX T plastic 16 indoor RS485 ANT-REMOTE plastic n/a indoor outdoor Optional re ...

  • Schlage Panel Interface Module RS485 - page 8

    IR Security & Safety 575 Birch St., Forestville, Connecticut 06010 / (860) 584-9158 / (860) 584-2136 fax P/N: M053-016-A http://www.ir support.net Page 8 of 15 2. Inst alling the PIM-485-16-TD-NXT 2.1 Configuring the PIM-485-16-TD-NXT to Emulate DR42xx DigiReaders The Schlage C onfiguration & Demonst ration To ol (CDT, versi on 1.4 or highe ...

  • Schlage Panel Interface Module RS485 - page 9

    IR Security & Safety 575 Birch St., Forestville, Connecticut 06010 / (860) 584-9158 / (860) 584-2136 fax P/N: M053-016-A http://www.ir support.net Page 9 of 15 Point Numbers ADDR/READER MIRO Door Position Sw itch Request to Exit Strike Relay 0 x 1 2 1 1 x 3 4 2 2 x 5 6 3 3 x 6 8 4 4 x 9 10 5 5 x 11 12 6 6 x 13 14 7 7 x 15 16 8 8 x+1 1 2 1 9 x+1 ...

  • Schlage Panel Interface Module RS485 - page 10

    IR Security & Safety 575 Birch St., Forestville, Connecticut 06010 / (860) 584-9158 / (860) 584-2136 fax P/N: M053-016-A http://www.ir support.net Page 10 of 15 2.2 Connecting the PIM-485-16-TD-NXT to a Star I/II Access Control Unit Note: Make certa in that that Star I/II Te rminal Block TB1 is co nf igured for the S-NET communication protocol. ...

  • Schlage Panel Interface Module RS485 - page 11

    IR Security & Safety 575 Birch St., Forestville, Connecticut 06010 / (860) 584-9158 / (860) 584-2136 fax P/N: M053-016-A http://www.ir support.net Page 11 of 15 2.3 Linking the PIM-485-16-TD-NXT to WAPMs 2.3.1 How t o Set an RF Channel One of fifteen RF chan nels can be set using DIP switch SW7 on the PIM . Table 2-5 s hows how to set SW7 to se ...

  • Schlage Panel Interface Module RS485 - page 12

    IR Security & Safety 575 Birch St., Forestville, Connecticut 06010 / (860) 584-9158 / (860) 584-2136 fax P/N: M053-016-A http://www.ir support.net Page 12 of 15 2.4 PIM-485-16-TD-NXT Card Formats The PIM-485-16-TD-NXT accepts a 26 bit Wiegand format, strips off the two pa rity bits and the eight bit facility code field, the resulting 16 bit car ...

  • Schlage Panel Interface Module RS485 - page 13

    IR Security & Safety 575 Birch St., Forestville, Connecticut 06010 / (860) 584-9158 / (860) 584-2136 fax P/N: M053-016-A http://www.ir support.net Page 13 of 15 3. Cont acting Schlage For questions regarding Wyreless Access™: customerservice@recog nition-source.com sales@recognition-sourc e.com techsupport@recogni tion-source.com www.recognit ...

  • Schlage Panel Interface Module RS485 - page 14

    IR Security & Safety 575 Birch St., Forestville, Connecticut 06010 / (860) 584-9158 / (860) 584-2136 fax P/N: M053-016-A http://www.ir support.net Page 14 of 15 4. FCC Compliance & W arnings 4.1 FCC Compliance • This device has been auth orized by the FCC Rule s and Industry Cana da. • This device complies with the limits for a Class B ...

  • Schlage Panel Interface Module RS485 - page 15

    IR Security & Safety 575 Birch St., Forestville, Connecticut 06010 / (860) 584-9158 / (860) 584-2136 fax P/N: M053-016-A http://www.ir support.net Page 15 of 15 5. Revision History Version Date Changes X001 07/03/02 prelimi nary in house rel ease for com ments X001.1 09/06/02 updated Co nfigurin g and Lin king sections for new C DT versi on 001 ...

Fabbricante Schlage Categoria Network Router

I documenti che otteniamo dal fabbricante del dispositivoSchlage Panel Interface Module RS485 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Schlage
- manuali per l’uso Panel Interface Module RS485
- schede prodotto Schlage
- opuscoli
- o etichette energetiche Schlage Panel Interface Module RS485
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Schlage Panel Interface Module RS485.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Schlage Panel Interface Module RS485, manuali di manutenzione, brevi manuali o manuali utente Schlage Panel Interface Module RS485. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Schlage Panel Interface Module RS485.

Manuali per l’uso simili

Manuale completo del dispositivo Schlage Panel Interface Module RS485, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Schlage Panel Interface Module RS485 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Schlage Panel Interface Module RS485.

Il manuale per l’uso completo Schlage, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Schlage Panel Interface Module RS485 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Schlage Panel Interface Module RS485, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Schlage Panel Interface Module RS485 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Schlage Panel Interface Module RS485 - che ci dovrebbe aiutare nei primi passi durante l'uso Schlage Panel Interface Module RS485
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Schlage Panel Interface Module RS485
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Schlage Panel Interface Module RS485 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Schlage Panel Interface Module RS485?

Utilizza il modulo sottostante

Se non hai risolto il problema con Schlage Panel Interface Module RS485 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Schlage Panel Interface Module RS485 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)