Manuale per l’uso POSline SC2100

52 pagine Non applicabile
Scarica

Vai alla pagina of 52

Summary
  • POSline SC2100 - page 1

    Ba r code Scanner Magstripe P r ogramming Manual Decoder & Scanner ...

  • POSline SC2100 - page 2

    1 Getting Started ............................................................ 2 Setup Procedures ....................................................... 3 Setup Flow Chart .........................................................4 Group 0 : Interface Selection................................ 5 Group 1 : Device Selection for keyboard Interface..... ...

  • POSline SC2100 - page 3

    2 Getting Started T o install a keyboard wedge barcode scanne r , follow the steps listed below: 1) Make sure that the scanner has the correct Y (U)- cable for the system (a PC or terminal) 2) T urn off the power of the system 3) Unplug the keyboard from the system 4) Connect the Y (U)- cable to the system and keyboard 5) T urn on the power of the ...

  • POSline SC2100 - page 4

    3 Barcode Scanner Setup P r ocedu r es 1) Locate a group that contains the parameters to be changed. 2) Scan the "Enter Group #" label. The scanner will sound beeps indicate that setup is in progress 3) Scan the label representing the parameter to be changed 4) Scan the "Exit" to end the group currently selected, the scanner wil ...

  • POSline SC2100 - page 5

    4 ENTER GROUP Setup Flow Chart SELECT ITEMS EXIT Set All Defaults Show V ersion Note: (*) denotes default setting options marked by ( ) only available upon request. are ...

  • POSline SC2100 - page 6

    5 Group 0: Interface Selection KEYBOARD ENTER GROUP EXIT RS-232 (W AND) (OCIA) (DTMF) Reserved 2 Resered 3 Reserved 4 Note: The interface is pre-set at factory according to the model of the device. ...

  • POSline SC2100 - page 7

    6 Group 1: Device Selection for Keyboard Interface PC/A T , PS/2 50,60,70,80(*) PC/XT PS/2 25, 30 (NEC 9801) (IBM 5550) (PS 55) (NEC N5520) (ACER 7300) (KW105D/ CT -700A/W ANG 5120) (W ANG 5425) (MAC_SE) (LC-6533) ENTER GROUP EXIT Note: Options marked by ( ) are only available upon request. ...

  • POSline SC2100 - page 8

    7 Group 1: Device Selection for Keyboard Interface ENTER GROUP EXIT (IBM3196, 3197, 3476, 3477) Reserved 8 Reserved R IBM3197 IBM3477 Reserved 6 Reserved Q 9 Reserved Reserved T IBM 3476 5 Reserved 7 Reserved ...

  • POSline SC2100 - page 9

    8 Group 2: Inter character Delay ENTER GROUP Start Keyboard Setting Scan Enter Group 2 Label -- > Scan Start Keyboard (or RS-232) Setting Label --> Scan two digits labels in T able-Hex --> Scan Exit Label Start RS-232 Setting Keyboard Default V alue: 05 RS-232 Default V alue : 00 EXIT ...

  • POSline SC2100 - page 10

    9 Group 3: Language for Keyboard Interface ENTER GROUP U.S. (*) ENGLAND FRANCE GERMANY IT AL Y BELGIUM SWEDEN/FINLAND SP ANISH DENMARK POR TUGAL SWISS NOR W A Y EXIT ...

  • POSline SC2100 - page 11

    10 Group 3: Language for Keyboard Interface ENTER GROUP CANADA HOLLAND POLAND LA TIN JAP AN 1 Reserved 2 Reserved 3 Reserved (IBM THINK-P AD FOR JAP AN) (P ANASONIC CF- FOR JAP AN) II EXIT Note: Options marked by ( ) are only available upon request. ...

  • POSline SC2100 - page 12

    11 Group 4: T erminator KEYBOARD ENTER GROUP NONE CR (*) SP ACE TA B ESC CTRL-C EXEC EXIT ...

  • POSline SC2100 - page 13

    12 Group 4: T erminator RS-232 ENTER GROUP EXIT NONE CR (*) CR/LF LF SP ACE TA B ESC CTRL-C STX..ETX XON.. XOFF EOT ...

  • POSline SC2100 - page 14

    13 Group 5: Scan Mode ENTER GROUP EXIT 1: T rigger On/Of f 2: T rigger On/ Good Read Off (*) 3: T rigger On/ Good Read Off/ Delay T imeout = ? 4: Continuous/ T rigger Off 5: Continuous/ LED Always on 6: Continuous/ No T rigger 7: Continuous/ T esting 8: Continuous/ T rigger Off/ Delay T imeout = ? Delay T imeout Setting: Scan Enter Group 5 Label -- ...

  • POSline SC2100 - page 15

    14 Group 5: Scan Mode ENTER GROUP EXIT FLASH OFF(*) FLASH ON Note: Scan mode setting is only available for Laser type scanner . CCD/ ...

  • POSline SC2100 - page 16

    Preamble Postamble Preamble & Postamble Setting: Scan Enter Group 6 Label --> Scan Preamble or Postamble Label --> Refer to ASCII T able(page 46), scan two digits in T able-Hex (Page 45) Representing one character , maximum 10 characters can be accepted. --> Scan Confirm Label in T able-Hex (Page 45) Scan Exit Label 15 Group 6: Pr eamb ...

  • POSline SC2100 - page 17

    16 Group 7: RS-232 Parameters Baud Rate Data Bit EXIT BIT 7 BIT 8 (*) ENTER GROUP 1200 4800 19200 600 2400 9600(*) 38400 ...

  • POSline SC2100 - page 18

    17 Group 7: RS-232 Parameters Parity : Handshaking: EXIT NONE (*) ODD EVEN NONE (*) XON/XOFF Scanner Ready Data Ready ACK/NAK ENTER GROUP ...

  • POSline SC2100 - page 19

    18 Group 7: RS-232 Parameters EXIT 100 ms 300 ms 500 ms 1 sec 5 sec 10 sec 3 sec (*) 00 ENTER GROUP (ACK/NAK Response T ime CTS Observation T ime:) ...

  • POSline SC2100 - page 20

    19 Group 8: CODE 39 / CODE 32 EXIT Standard (*) Full ASCII T ransmit Start/End Character Code 39 Disable (*) Enable T ransmit Check Character V erify Checksum ENTER GROUP Enable (*) Disable Enable (*) Disable Enable Disable (*) ...

  • POSline SC2100 - page 21

    20 Group 8: CODE 39 / CODE 32 EXIT V erify Normal (*) V erify Strick Disable CODE 32 (*) ENTER GROUP Enable CODE 32 ...

  • POSline SC2100 - page 22

    21 Group 9-1: Interleaved 2 OF 5 EXIT T ransmit Check Character Disable Enable (*) V erify Checksum Disable (*) Enable Length Define Min: 4 Max: 48 Scan Enter Group 9-1 Label --> Scan Length Define Label --> Scan Four Digit Labels in T able Hex (Page 43) --> Scan Confirm Label in T able-Hex --> Scan Exit Label Barcode Length Setting: Us ...

  • POSline SC2100 - page 23

    22 Group 9-2: Industrial 2 OF 5 / IA T A EXIT T ransmit Check Character T ransmit Check Character IA T A Disable Disable (*) Enable (*) Enable ENTER GROUP Length Define Min: 2 Max: 24 Scan Enter Group 9-2 Label --> Scan Length Define Label --> Scan Four Digit Labels in T able Hex (Page 43) --> Scan Confirm Label in T able-Hex --> Scan E ...

  • POSline SC2100 - page 24

    23 Group 9-3: Matrix 2 OF 5 EXIT T ransmit Check Character V erify Checksum Length Define Min: 2 Max: 40 Scan Enter Group 9-3 Label --> Scan Length Define Label --> Scan Four Digit Labels in T able Hex (Page 43) --> Scan Confirm Label in T able-Hex --> Scan Exit Label Barcode Length Setting: User Define 3 Sets A vailable Scan Enter Grou ...

  • POSline SC2100 - page 25

    24 Group 9-4: CHINA POST AGE EXIT T ransmit Check Character V erify Checksum Length Define Min: 2 Max: 40 Scan Enter Group 9-4 Label --> Scan Length Define Label --> Scan Four Digit Labels in T able Hex (Page 43) --> Scan Confirm Label in T able-Hex --> Scan Exit Label Barcode Length Setting: User Define 3 Sets A vailable Scan Enter Gro ...

  • POSline SC2100 - page 26

    25 Group 10: Code 128 EXIT Enable/Disable Checkdigit Disable Note: Options marked by ( ) are only available upon request ENTER GROUP Disable Enable (*) Disable (*) Enable UCC/EAN/128 Enable (*) (not send checkdigit) ...

  • POSline SC2100 - page 27

    26 Group 1 1: CODE 1 1 EXIT Enable/Disable Checkdigit Number of Check Character T ransmit Check Character T wo (*) One ENTER GROUP Enable (*) Disable Enable Disable (*) Enable (*) Disable ...

  • POSline SC2100 - page 28

    27 Group 12: Code 93 EXIT ENTER GROUP V erify Checkdigit Disable (*) Enable Enable (*) Disable ...

  • POSline SC2100 - page 29

    28 Group 13: MSI-PLESSEY EXIT V erify Checkdigit Enable MOD T ransmit/T runcate Checkdigit Enable MOD 1 1-10 T runcate 1 & 2 checkdigit st nd Enable MOD 10 (*) T ransmit checkdigit (*) Enable MOD 10-10 T runcate 1 checkdigit st ENTER GROUP Enable (*) Disable Enable (*) Disable ...

  • POSline SC2100 - page 30

    29 Group 14: CODABAR / NW7 EXIT Disable Disable (*) Enable (*) Enable ABCD/ABCD ABCD/TN*E abcd/abcd (*) abcd/tn*e ENTER GROUP T ransmit Start/End Character Start/End T ransmit T ype ...

  • POSline SC2100 - page 31

    30 Group 15: Code 4 EXIT Disable (*) Enable ENTER GROUP ...

  • POSline SC2100 - page 32

    Enable (*) 31 Group 16-1: EAN-13/JAN-13 EXIT ENTER GROUP Disable Enable (*) Disable (*) Enable ADD-ON 2/5 Disable Enable (*) T ransmit Check Character Disable (*) Enable T runcate 1 digit st Disable (*) Enable T runcate 2 digit nd EAN Checkdigit Disable ...

  • POSline SC2100 - page 33

    32 Group 16-2: UPC-A EXIT ENTER GROUP Disable Enable (*) Disable (*) Disable Disable (*) Enable Enable (*) Enable ADD-ON 2/5 T ransmit Check Character T runcate Leading Digit UPC-A Convert to EAN-13 Enable Disable (*) ...

  • POSline SC2100 - page 34

    33 Group 16-3: EAN-8/JAN-8 EXIT ENTER GROUP Disable Enable (*) Disable (*) Disable Disable (*) Disable (*) Enable Enable (*) Enable Enable 1 (add zeros in the front of barcode) Enable 2 (add zeros in the middle of barcode) ADD-ON 2/5 T ransmit Check Character T runcate Leading Digit EAN-8 Convert to EAN-13 ...

  • POSline SC2100 - page 35

    34 Group 16-4: UPC-E EXIT ENTER GROUP Disable Enable (*) T ransmit Check Character Disable (*) Enable T runcate Leading Digit Disable (*) Enable UPC-E Convert to UPC-A Disable Enable (*) Disable (*) Enable ADD-ON 2/5 ...

  • POSline SC2100 - page 36

    35 Group 16-5: ISBN/ISSN EXIT ENTER GROUP Disable (*) Enable ...

  • POSline SC2100 - page 37

    36 Group 17: General Parameters EXIT ENTER GROUP Buzzer Pitch (Default : 21) Buzzer Duration (Default: AA) Buzzer Pitch & Buzzer Duration Setting: Scan Enter Group 17 Label --> Scan Buzzer Pitch or Buzzer Duration Label --> Scan T wo Digit Labels in T able-Hex --> Scan Confirm Label in T able-Hex --> Scan Exit Label Disable Enable ( ...

  • POSline SC2100 - page 38

    Group 18: Code ID Setting EXIT ENTER GROUP CODE 39/CODE 32 INTERLEA VED 2 OF 5 INDUSTRIAL 2 OF 5 MA TRIX 2 OF 5 CHINA POST AGE CODE 128 CODE 93 CODE 1 1 MSI/PLESSEY CODABAR/NW7 EAN-13 EAN-8 UPC-E CODE 4 Note: Refer to ASCII T able, scan two hexadecimal labels in T able Hex to represent one character UPC-A 37 ...

  • POSline SC2100 - page 39

    38 Group 19: W AND T ype Parameters EXIT ENTER GROUP BAR=LOW BAR=HIGH(*) Lowest Low (*) High Highest Data Format T ransmit in Normal Format (*) T ransmit in Code 39 Format T ransmit in Code 128 Format Scan Speed ...

  • POSline SC2100 - page 40

    39 Group 20-1: (Magnetic Parameters) EXIT ENTER GROUP Disable Enable (*) T rack 1/2/3 (*) T rack 1/3/2 T rack 2/1/3 T rack 2/3/1 T rack 3/2/1 T rack 3/1/2 Note: Options marked by ( ) are only available upon request T rack Order ...

  • POSline SC2100 - page 41

    40 Group 20-1: (Magnetic Parameters) EXIT ENTER GROUP T rack 1&2&3 any (*) T rack 1 only T rack 2 only T rack 3 only T rack 1 and 2 T rack 2 and 3 T rack 1 and 2 and 3 ISO (*) (JIS-2) Note: Options marked by ( ) are only available upon request T rack Selection ...

  • POSline SC2100 - page 42

    41 Group 20-2: (Magnetic Parameters) EXIT ENTER GROUP Tk1 Default : % Tk2 Default: ; Tk3 Default: ; Tk1 Default : Null Tk2 Default: Null Tk3 Default: Null Tk1&2&3 Default: ? Tk1&2&3 Default: Null Magnetic Output Data Format: STX - Tk1 Start Sentinel - Tk1 Data - End Sentinel - Tk1 - DLE STX - Tk2 Start Sentinel - Tk2 Data - End Sent ...

  • POSline SC2100 - page 43

    42 Group 21: (Function Key Emulation) EXIT ENTER GROUP Enable Enable Function Key Emulation: Scan Enter Group 21 Label --> Scan Enable Label --> Scan Exit Label Disable (*) Full ASCII Code 39 Enable 1: T o concatenate a function key with input data, please refer to Function Key T able for its hexadecimal representation. For Example: Preamble ...

  • POSline SC2100 - page 44

    Function Code for PC XT/A T 43 F1 ($A) F7 ($G) F2 ($B) F8 ($H) F3 ($C) F9 ($I) F4 ($D) F10 ($J) F5 ($E) F1 1 ($K) F6 ($F) F12 ($L) ...

  • POSline SC2100 - page 45

    Function Code for PC XT/A T 44 Enter ($M) End ($U) ($B) T ab ($N) PgUp ($V) BS ($O) PgDn ($W) Up ($P) Ins ($X) Down ($Q) Del ($Y) Left ($R) Esc (%A) Right ($S) Home ($T) ...

  • POSline SC2100 - page 46

    T able-Hex : HEXADECIMAL 45 0 1 2 3 4 5 6 7 8 9 A B C D E F Confirm ...

  • POSline SC2100 - page 47

    ASCII T ABLE 46 H/I 0 1 2 3 4 5 6 7 0 NULL DLE SP 0 @ P ` p 1 SOH DC1 ! 1 A Q a q 2 STX DC2 " 2 B R b r 3 ETX DC3 # 3 C S c s 4 EOT DC4 $ 4 D T d t 5 ENQ NAK % 5 E U e u 6 ACK SYN & 6 F V f v 7 BEL ETB ' 7 G W g w 8 BS CAN ( 8 H X h x 9H T E M ) 9 I Y i y A LF SUB * : J Z j z B VT ESC + ; K [ k { CF F F S . < L l | DC R G S - = _ ...

  • POSline SC2100 - page 48

    H/I 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 1 2 3 4 5 6 7 8 9 10 1 1 12 13 14 15 1 1 6 1 7 1 8 1 9 2 0 2 12 22 3 2 4 2 5 2 6 2 7 2 8 2 93 0 3 1 2 3 2 3 3 3 4 3 5 3 6 3 73 83 9 4 0 4 1 4 2 4 3 4 4 4 54 6 4 7 3 4 8 4 9 5 0 5 1 5 2 5 35 45 5 5 6 5 7 5 8 5 9 6 0 6 16 2 6 3 4 6 4 6 5 6 6 6 7 6 8 6 97 07 1 7 2 7 3 7 4 7 5 7 6 7 77 8 7 9 5 8 0 8 1 8 2 8 3 8 4 ...

  • POSline SC2100 - page 49

    1 6 Function DB9F Din6M/5M(240 ) Start of Scan 1 6 Signal Data 2 2 Led Indicator 3 --- T rigger 5 5 Power Enable 6 4 GND 7 3 VCC+5V 9 1 10Pin Modular Plug TTL Signal Output RJ-45 Male 10P10C TTL W AND KB RS-232 KB USB 1R T S 2 CTS 3 PWR-CTL TX 4 GND GND GND GND GND 5 GOOD- GOOD- PC- PC- READ READ DA T A DA T A 6 DA T A DA T A PC-CLK PC-CLK 7 VCC VC ...

  • POSline SC2100 - page 50

    W and Emulation Signal Output RS-232 Signal Output Function DB9F Din5M Din6M/Din5M (180 ) (240 ) Signal Data 2 1 2 GND 7 2 3 VCC+5V 9 3 1 Note : "F" stands for a female connector , while "M" stands for a male connector . Function DB9F+DC (or without DC) GND 5 CTS 7 RT S 8 RX 3 TX 2 VCC+5V 9 Note : For PC applications, a cable wi ...

  • POSline SC2100 - page 51

    Keyboard Signal Output Funcion Din5F Din5M Mini-Din6M Mini-Din6F GND 4 4 5 5 PC_Data --- 2 --- 4 PC_CLK --- 1 --- 6 Vcc+5V 5 5 2 2 KB_CLK 1 --- 6 --- KB_Data 2 --- 4 --- USB Signal Output FUNCTION USB-A GND 4 Vcc 1 D+ 3 D- 2 50 USB PLUG 1 4 DIN5M DIN5F 3 1 5 4 2 2 4 5 1 3 MD6M MD6F 3 3 1 1 5 5 6 6 4 4 2 2 ...

  • POSline SC2100 - page 52

    V20040930 ...

Fabbricante POSline Categoria Barcode readers

I documenti che otteniamo dal fabbricante del dispositivoPOSline SC2100 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici POSline
- manuali per l’uso SC2100
- schede prodotto POSline
- opuscoli
- o etichette energetiche POSline SC2100
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso POSline SC2100.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione POSline SC2100, manuali di manutenzione, brevi manuali o manuali utente POSline SC2100. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto POSline SC2100.

Manuali per l’uso simili

Manuale completo del dispositivo POSline SC2100, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare POSline SC2100 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti POSline SC2100.

Il manuale per l’uso completo POSline, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale POSline SC2100 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice POSline SC2100, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per POSline SC2100 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo POSline SC2100 - che ci dovrebbe aiutare nei primi passi durante l'uso POSline SC2100
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del POSline SC2100
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio POSline SC2100 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su POSline SC2100?

Utilizza il modulo sottostante

Se non hai risolto il problema con POSline SC2100 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con POSline SC2100 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)