    721 OWNERS M A NUAL for POST-MIX DISPENSERS MODELS : 9454 9456 Includes: Installation Operation Use & Care Servicing Instructions p/n 83188 Rev. C ECN- 12 738 M 721 04 0811 cps Model 9456 3-Flavor Dispenser ...

  • Bloomfield 9456 - page 2

    NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged b y skilled personnel before le aving the factory. Upon acceptance of this shipm ent, the transportation company assumes full responsibility for its safe delivery. IF SHIPMENT ARRIVES DAMAGED: 1. VISIBLE LOSS OR DA M AGE: Be certain that any ...

  • Bloomfield 9456 - page 3

    MODEL STYLE VOLT S WAT TS AMP S 1ø POWER SUPPLY CORD 9454 2-FLAVOR 120 VAC 1ø 1500 W 12.5A 9456 3-FLAVOR NEMA 5-15P 1 TABLE OF CONTENTS SPECIFIC ATIONS Thank You for pu rchasing th is Bloomfield Industries appliance. Proper installation, professional operation and consistent maintenance of this appliance w ill ensure that it gives you the very be ...

  • Bloomfield 9456 - page 4

    FE AT U R E S AN D OP E R AT I N G CO N T R O L S 2 ...

  • Bloomfield 9456 - page 5

    FEATURES AND OPER ATING CONTROLS (continued) 3 ITEM DESCRIPTION COMMENTS 1 WA TE R TA NK 2 WATER LEVEL PROBES SENSE HIGH AND LOW WATER LEVE LS 3 DISPENSER W ATER SUPPLY TUBES 9456 SHOWN. FOR 9454, CENTER TUBE I S BLANKED 4 WATER TANK FILL TUBE 5 VENT / OVERFLOW 6 HEATING ELEMENT 1500 W ATT ELEMENT TO HEAT W ATER IN TANK 7 DRAIN FITTING DRAIN W ATER ...

  • Bloomfield 9456 - page 6

    FEATURES AND OPERATING CONTROLS (continued) 4 INTERNAL COMPONENTS ITEM DESCRIPTION COMMENTS 30 W HIPPER MOTORS 31 AUGER MOTOR 32 VENT "TEE" 33 DISPENSE SOLENOIDS 34 TEMPERATURE CONTROL THERMOSTAT CONTROLS HEATING ELEMENT 35 HI-LIMIT THERMOSTAT OVER-TEMP PROTECTION 36 W ATER FILL SOLENOID SUPPLIES W ATER TANK 37 COLD W ATER "TEE" ...

  • Bloomfield 9456 - page 7

    PRECAUTIONS A ND GENERAL INFORM A TION 5 WARNING: ELECTRIC SHOCK HAZARD All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which requ ire the use of tools. Failure to heed this warning can result in electrical s hock. WARNING: INJURY HA ZARD All installation pro ...

  • Bloomfield 9456 - page 8

    INSTALL ATION 6 RE A D THIS CAREFULL Y BEFORE ST A RTING TH E INST A LLA TION Unpack the unit. Inspec t all com ponents for completeness and condition. Ensure that all packing materials have been removed from the unit. Read all instructions in this m anual carefully before st arting installation of this f ryer. READ AND UNDE RSTAND ALL LABELS AND D ...

  • Bloomfield 9456 - page 9

    INSTALLATION (continued) 7 WARNING: SHOCK HAZARD Brewer must be properly grounded to prevent possible shock hazard. DO NOT assume a plumbing line will provide suc h a ground . Electrical shock will cause death or serious injury. IMPORTANT: Supply power mu st match nameplate for voltage and phase. Connecting to the wrong voltage will damage the brew ...

  • Bloomfield 9456 - page 10

    OPERATION 8 OPERATING MODES IMPORTANT: Dispensers used to dispense both hot and cold drinks, must be connected to a co ld wat erline . Portab l e un its ha ve no mean s of providing t wo diff erent wa ter tem per atures, INITIAL SET-UP: WATERLINE-CONNECTED DISPENSERS 1. Turn POWER switch OFF . Turn W ATERLINE / PORTABLE switch to WATE RLI NE Turn H ...

  • Bloomfield 9456 - page 11

    OPERATION (continued) 9 INITIAL SET-UP: PORTABLE DISPENSERS 1. Turn PO W ER switch OFF . Turn W ATERLINE / PORTABLE switch to PORTABLE Turn HE ATER switch OFF . Turn COLD/HOT / HOT/HOT switch to HOT/HOT Turn DISPE NSE / FLUSH switch to flush 2. Add water to tank. NOTE: To avoid an overflow when the water bottle is installed, f ill only until water ...

  • Bloomfield 9456 - page 12

    OPERATION (continued) NOTE : Hoppers and motors for various products are essenti ally identical. In a cold / hot dispensing mode, the cold product must be placed in the left dispen ser only . Otherwise, product m ay be place d in and dispen sed fr om either hopper. SUGGESTION : For eas y identification of the hopper contents, a 2” strip o f “fr ...

  • Bloomfield 9456 - page 13

    CLEANING I NSTRUCTIONS PROCEDURE: Daily Cleaning - Dispenser PRECAUTIONS: Avoid spla shing hot water f rom tank FREQUENCY: Daily TOOLS: Mild Detergent, Clean So ft Cloth or S ponge 1. Open f ront door. Turn the DISPENSE / FLUSH switch to the FLUSH position 2. Place a large cup under the right dispensing spout. Press and hold the left dispense butto ...

  • Bloomfield 9456 - page 14

    CLEANING I NSTRUCT IONS (continued) 12 PROCEDURE: Weekly Cleaning & Sanitizing PRECAUTIONS: Disconnect disp enser fro m electric pow er and allo w to cool. Av oid splashing hot water f rom tank FREQUENCY: Weekly TOOLS: Small Flat-Blade Screwdriver Bott le Brush of Stiff Bristle Brush Mild D etergent, Clean Sof t Cloth or Sponge 1. Disconnect di ...

  • Bloomfield 9456 - page 15

    CLEANING INSTRUCTIONS (continued) 13 PROCEDURE: Weekly Cleaning - Hoppers PRECAUTIONS: None FREQUENCY: Weekly, or as necessary TOOLS: Mild Detergent, Clean Soft Cloth or Sponge 1. W hen refilling hopper, insp ect auger spring, star wheel and inside of hopper for a "crusty" buildup. 2. W hen nece ssa ry, disassemble hopper and w ash all pa ...

  • Bloomfield 9456 - page 16

    TROUBLESHOOTING SUGGEST IONS 14 CAUTION: SHOCK HA ZA RD Opening access panels may expose un insulated electrical components. Disconnect dispenser from electrical pow e r before removing any panel. Do not attempt to repair or replace components without first unplugging the pow er cord. Use caution when adjusting water flow rates or testing voltages ...

  • Bloomfield 9456 - page 17

    TROUBLESHOOTING SUGGESTIONS (continued) 15 PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION WATER DRIPS OR FLOWS OUT SPOUT WITH POWER OFF Foreign particles inside dispense valve Remove valve coil, gently lif t off valve dome and diaphragm, clean diaph ragm Torn diaphragm in dispenser valv e Replace diaphragm Defective dispense valve Replace dispense valve ...

  • Bloomfield 9456 - page 18

    SERVICING INSTRUCTIONS 16 CAUTION: SHOCK HAZARD Opening access pan els may expose uninsu lated electr ical components. Disconnect dispenser f rom electrical power before removing any panel. Do not attemp t to repair or replace components without first unplugging the po wer cor d . Use caution when adjusting water flow rates or testing voltages with ...

  • Bloomfield 9456 - page 19

    SERVICING INSTRUCTIONS 17 COLD WATE R A DJUSTMENT The dispenser can dispense both hot and cold beverage on ly when connected t o a wat er line with the water suppl y valve open. Cold product is available from the left dispenser only, and only when the COLD/HOT, HOT/ HO T selector switch is set in COLD/HOT position. 1. Unplug po wer cord. 2. Remove ...

  • Bloomfield 9456 - page 20

    SERVICING INSTRUCT IONS (continued) 18 REPLACE PRODUCT DELIVERY AUGER Before at tempting majo r changes, such a s installi ng a diff erent rate product delivery auger, consult your product supplier for recommendations as to the required ratio product weight per volume of water. See th e char t belo w for auger spring delivery rates. p/n PRODUCT DEL ...

  • Bloomfield 9456 - page 21

    SERVICING INSTRUCTIONS (continued) 19 CAUTION: CHEMICA L BU RN HA ZA RD Deliming chemicals may be caustic. Wear appropriate protective gloves and goggles during this procedur e. Never siphon deliming chemicals or solutions by mouth. This operation sh ou ld on l y be performed by qualified and experienced service personnel. IMPORTANT: DO NOT spill, ...

  • Bloomfield 9456 - page 22

    EXPLODED VIEWS 20 ...

  • Bloomfield 9456 - page 23

    EXPLODED VIEWS (continued) 21 ...

  • Bloomfield 9456 - page 24

    EXPLODED VIEWS (continued) 22 ...

  • Bloomfield 9456 - page 25

    EXPLODED VIEWS (continued) 23 ...

  • Bloomfield 9456 - page 26

    EXPLODED VIEWS (continued) 24 ...

  • Bloomfield 9456 - page 27

    25 SERVICE PARTS LIST Nut w/ Lockwasher S0311 Nut, Nylon 1/2-13 S0313 Nut, Hex SS 6-32 x 5/15 S0316 Nut, NS 4-40 SS S0343 Screw SS 6-32 x 1/4 S0434 Screw SS 6-32 x 3/8 S0435 Screw SS 10-32 x 3/8 S0444 Washer SS .187 ID S0514 Washer SS .500 ID S0518 Washer Nylon .171 ID S0536 Panel Assy, Left Side S10036 Bracket, Vac (Model 9454) S10060 Harness LNC/ ...

  • Bloomfield 9456 - page 28

    WIRING DIA GRAM 26 9454 ...

  • Bloomfield 9456 - page 29

    WIRING DIA GRAM 27 9456 ...

  • Bloomfield 9456 - page 30

    Bloo mf iel d Indu st ri es, Inc . Division of Carrier Co mmercial Refrigeration In US and Can ada T elep h one: 775 -689- 5700 Fa x: 888 -492- 2783 Fa x: 800 -356- 5142 () websi te: www . wells bl oomfi eld. c om fo r order s onl y Bloomf i eld I ndust r ies p r oudly suppor ts CFESA Commerc ial Fo od Equ ipment Servi ce Associ a tio n ...

Fabbricante Bloomfield Categoria Beverage Dispenser

I documenti che otteniamo dal fabbricante del dispositivoBloomfield 9456 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Bloomfield
- manuali per l’uso 9456
- schede prodotto Bloomfield
- opuscoli
- o etichette energetiche Bloomfield 9456
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Bloomfield 9456.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Bloomfield 9456, manuali di manutenzione, brevi manuali o manuali utente Bloomfield 9456. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Bloomfield 9456.

Manuali per l’uso simili

Manuale completo del dispositivo Bloomfield 9456, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Bloomfield 9456 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Bloomfield 9456.

Il manuale per l’uso completo Bloomfield, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Bloomfield 9456 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Bloomfield 9456, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Bloomfield 9456 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Bloomfield 9456 - che ci dovrebbe aiutare nei primi passi durante l'uso Bloomfield 9456
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Bloomfield 9456
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Bloomfield 9456 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Bloomfield 9456?

Utilizza il modulo sottostante

Se non hai risolto il problema con Bloomfield 9456 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Bloomfield 9456 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)