Manuale per l’uso Raypak 055B

32 pagine 1.13 mb
Scarica

Vai alla pagina of 32

Summary
  • Raypak 055B - page 1

    Part No. 240428 CATALOG NO. 6100.52-K Effective: 3-01-00 Replaces: 3-15-99 ® OPERA TING AND INST ALLA TION INSTRUCTIONS Models 055B VERSA SP A and HOT TUB HEA TER This manual should be maintained in legible condition and kept adjacent to the heater or kept in a safe place for future reference. WARNING: If the information in these instructions are ...

  • Raypak 055B - page 2

    Contents 2 PART ONE - Owner's Operating Instructions 2 SECTION 1 / START-UP PROCEDURES 2 Before Start-Up 3 Lighting Instructions & Shut-Off Procedures (manually lighted pilot MV) 4 Operating Instructions & Shut-Off Procedures (automatically lighted pilot IID) 5 After Start-Up 5 SECTION 2 / CAUTION 5 SECTION 3 / MAINTENANCE & CARE P ...

  • Raypak 055B - page 3

    P ART ONE - OWNER'S OPERA TING INSTRUCTIONS SECTION 1 / START-UP PROCEDURES BEFORE START-UP BURNERS Clean main burners and air louvers of dust, lint and debris. Keep heater area clear and free from com- bustibles, flammable liquids and chemicals. Do not obstruct the flow of combustion and ventilating air. WARNING: IF YOU DO NOT FOLLOW THESE IN ...

  • Raypak 055B - page 4

    1. STOP! Read the safety information above. 2. Set the thermostat on the lowest setting. 3. Turn On/Off switch to the "Off" position. 4. Remove heater door panel. 5. Push in gas control knob slightly and turn clock- wise to "Off". NOTE: Knob cannot be turned from "Pilot" to "Off" unless knob is pushed in slig ...

  • Raypak 055B - page 5

    TO TURN OFF GAS TO APPLIANCE 4 1. STOP! Read the safety information above. 2. Set the thermostat to the lowest setting. 3. Turn off all electric power to the appliance. 4. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand. 5. Remove heater door panel. 6. Push in gas contro ...

  • Raypak 055B - page 6

    AFTER START-UP Feel the inlet and outlet pipes. Outlet pipe should be only slightly warmer than the inlet. It should not be hot. WARNING: Should overheating occur or the gas sup- ply fail to shut off, turn off the manual gas control valve to the appliance. VISUAL INSPECTION With the heater on, remove the door and make a visual check of the pilot an ...

  • Raypak 055B - page 7

    4. Make visual check of the burner and pilot flame. Flame pattern on the main burner and pilot is indicated in the previous illustration. Yellow flame means restriction of the air openings. Lifting or blowing flame indicates high gas pressure. Low flame means low gas pressure. Should this occur, shut the heater off and contact your gas supplier or ...

  • Raypak 055B - page 8

    P ART 2 - INST ALLA TION / SER VICE INSTRUCTIONS SECTION 1 / RECEIVING EQUIPMENT On receipt of your equipment it is suggested that you visually check for external damage to the carton. If the carton is damaged, a note should be made on the Bill of Lading when signing for equipment. Remove the heater from the carton and if it is damaged, report the ...

  • Raypak 055B - page 9

    8 ALL HEATERS For clearances from combustible surfaces, see chart below. Clearances from Combustible construction. Indoor Installation: Top* (Drafthood) - 35"; Vent - 6"; Back - 2"; Right Side - 6"; Left Side - 6"; Floor - 0. Outdoor Installation: Top* (Stackless Top) - unobstructed; Back - 2"; Sides - 6". * Clear ...

  • Raypak 055B - page 10

    9 HIGH WIND CONDITIONS (OUTDOOR UNITS ONLY) In areas where high winds are frequent, it may be necessary to locate the heater a minimum of 3' from high vertical walls, or install a wind break so the heater is not in direct wind current. INDOOR HEATERS The design is also certified for indoor installation when equipped with the approved draft hoo ...

  • Raypak 055B - page 11

    VENT PIPING WARNING: Indoor boilers require a draft hood that must be connected to a vent pipe and properly vented to the outside. Failure to follow this procedure can cause fire or fatal carbon monoxide poisoning. Vent piping the same size or larger than the draft hood outlet is recommended, however, when the total vent height is at least ten (10) ...

  • Raypak 055B - page 12

    GAS SUPPLY CONNECTIONS Gas piping must have a sediment trap ahead of the heater gas controls, and a manual shut-off valve located outside the heater jacket. All gas piping should be tested after installation in accordance with local codes. CAUTION: The heater and its manual shut off valve must be disconnected from the gas supply during any pressure ...

  • Raypak 055B - page 13

    12 PLUMBING FOR WATER CONNECTIONS LOCATION The VERSA heater requires water flow and posi- tive pressure to fire and operate properly. It must therefore be installed downstream of the discharge side of the filter pump. A typical installation is plumbed as follows: 1. The inlet side of the filter is plumbed directly to the discharge side of the filte ...

  • Raypak 055B - page 14

    throughout its entire length and must pitch downward from the valve. No shut-off valve shall be installed between the relief valve and the drain line. Valve lever should be tripped at least once a year to ensure that waterways are clear. ELECTRICAL WIRING NOTE: If it is necessary to replace any of the original wiring, it must be replaced with 105 ? ...

  • Raypak 055B - page 15

    SPK 14 WIRING DIAGRAM KEY Fig. # 8096 Fig. # S86/S8600 S86 S8600 PINK CONNECTOR BLUE CONNECTOR For 120 V input power to the unit, connect the black wire to the “L1” or hot leg of the power supply . Connect the white wire to the “L2” or neutral leg of the power supply . Attach the wire nut to the red wire. There should be no connection to th ...

  • Raypak 055B - page 16

    WIRING DIAGRAM MILLIVOLT UNITS WITH MECHANICAL THERMOSTAT WIRING DIAGRAM MILLIVOLT UNITS WITH SOLID STATE THERMOSTAT Fig. # 2246e Fig. # 1934e 15 ...

  • Raypak 055B - page 17

    16 WIRING DIAGRAM 152178 Model 055 IID BL BL BL ...

  • Raypak 055B - page 18

    SECTION 4 / SERVICING INSTRUCTIONS GENERAL LOCATION OF CONTROLS Drain Valve Solid State Thermostat & Ignition Control Pressure Switch Burner & Pilot Thermal Fuse CONTROLS/ADJUSTMENTS/REPLACEMENTS CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper o ...

  • Raypak 055B - page 19

    PRESSURE SWITCH ADJUSTMENT: 1. With pump and heater on, turn adjustment knob ( clockwise) until a click is heard from the gas valve. 2. Turn adjustment knob (counter clockwise) 1/4 turn. 3. Turn pump off and on several times. Heater should shut off immediately. If it does not, repeat steps above until proper adjustment is made. Adjustment Knob Fig. ...

  • Raypak 055B - page 20

    BURNER DRAWER REMOVAL 1. Shut off main electrical power switch to heater. 2. Shut off gas upstream of heater. 3. Remove front door. 4. Disconnect gas line from gas valve. 5. Remove (2) screws that mount burner tray to unit. 6. Disconnect wires that terminate at gas valve, and thermal fuse. 7. Slide out burner tray. 8. Reverse above procedure to rei ...

  • Raypak 055B - page 21

    DESOOTING PROCEDURE CAUTION: SOOT IS COMBUSTIBLE. EXERCISE EXTREME CARE. NEVER USE A WIRE BRUSH. Soot can clog areas between fins and cause even- tual tube failure. Any sign of soot at the base of the burners or around the outer jacket indicates a need for cleaning. 1. Disconnect top portion of unit. (See heat ex- changer removal procedure steps 1 ...

  • Raypak 055B - page 22

    SECTION 5 / TROUBLE SHOOTING GUIDE IMPORTANT NOTICE These instructions are primarily intended for the use of qualified personnel specifically trained and experienced in the installation of this type of heating equipment and related system components. Installation and service personnel may be required by some states to be licensed. Persons not quali ...

  • Raypak 055B - page 23

    If pilot burner remains lit. Jump across pressure switch terminals If main burner does not fire, remove jumper Check for adequate water flow from filter Replace pressure switch Jump across thermostat If main burner fires, remove jumper If main burner does NOT fire... Jump across each high limit and remove jumper Replace thermostat Replace high limi ...

  • Raypak 055B - page 24

    ELECTRICAL (SOLID STATE THERMOSTAT MILLIVOLT) If the pool/spa/hot tub water is too cold, troubleshoot the system as follows: Check voltage at + and - terminals. VOLTAGE BETWEEN + 0.2 V and 0.75 V. (Polarity is critical) Set control to max. temperature. After 2-3 cycles, check water temperature. TEMPERATURE BELOW 105°F Disconnect sensor leads from ...

  • Raypak 055B - page 25

    ELECTRICAL (ELECTRONIC IGNITION IID) WARNING HIGH VOLTAGE For qualified Technicians ONLY NOTE: Some heaters may be equipped with an ignition module that shuts off pilot gas if pilot fails to light. To reset, interrupt power to heater. Intermittent Pilot System TROUBLESHOOTING HONEYWELL S8600 NOTE: Before troubleshooting, familiarize yourself with t ...

  • Raypak 055B - page 26

    ELECTRICAL (SOLID STATE THERMOSTAT IID) If the pool/spa/hot tub water is too cold, troubleshoot the system as follows: Check voltage at 24 V terminals. VOLTAGE BETWEEN 21.5-28.5 V. Set control to max. temperature. After 2-3 cycles, check water temperature. TEMPERATURE BELOW 105°F Disconnect sensor leads from circuit board. Measure sensor resistanc ...

  • Raypak 055B - page 27

    SECTION 6/REPLACEMENT PARTS LIST NOTE: To supply the correct part it is important that you state the model number, serial number and type of gas when applicable. Any part returned for replacement under standard company warranties must be properly tagged with RAYPAK return parts tag, completely filled in with the heater serial number, model number, ...

  • Raypak 055B - page 28

    27 13-P 15-P IID MV 1-P 14-P 9-P 12-P 3-P 7-P 14-P 5-P Fig. #8132.0 Fig. #8133.0 1-V 7-C 1-C 2-C 13-H 12-H 11-H 6-H 5-H 4-H 10-H 1-S 2-S 3-H 7-H 2-H 2-V 4-S 1-R 5-M 3-S 7-M 6-C 5-C 3-C 1-M 2-M 2-B 3-B 1-G 9-M 11-P 4-C 5-S 6-M 1-B 6-S 3-M 4-M 8-H ...

  • Raypak 055B - page 29

    28 ...

  • Raypak 055B - page 30

    29 ...

  • Raypak 055B - page 31

    LIMITED WARRANTY RAYPAK RESIDENTIAL SWIMMING POOL & SPA HEATERS GENERAL Raypak, Inc. warrants that all parts of this product will be free from defects in materials and workmanship under normal use a nd service for a period of TWO YEARS FROM THE DATE OF ORIGINAL PURCHASE FOR A SINGLE FAMILY RESIDENCE (ONE YEAR IF OTHER THAN FOR SINGLE FAMILY RES ...

  • Raypak 055B - page 32

    Raypak, Inc. , 31111 Agoura Road, Westlake Village, CA 91361-4699 (818) 889-1500 FAX (818) 889-4522 Raypak Canada LTD , 2805 Slough Street, Mississauga, Ontario, Canada L4T 1G2 (905) 677-7999 FAX (905) 677-8036 Raypak Australia Pty. Ltd , 7 Geddes St., Mulgrave, Victoria, Australia 3170 (6139) 560 4944 FAX (6139) 560 4974 Litho in U.S.A. www .rayp ...

Fabbricante Raypak Categoria Electric Heater

I documenti che otteniamo dal fabbricante del dispositivoRaypak 055B possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Raypak
- manuali per l’uso 055B
- schede prodotto Raypak
- opuscoli
- o etichette energetiche Raypak 055B
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Raypak 055B.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Raypak 055B, manuali di manutenzione, brevi manuali o manuali utente Raypak 055B. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Raypak 055B.

Manuali per l’uso simili

Manuale completo del dispositivo Raypak 055B, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Raypak 055B dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Raypak 055B.

Il manuale per l’uso completo Raypak, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Raypak 055B - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Raypak 055B, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Raypak 055B che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Raypak 055B - che ci dovrebbe aiutare nei primi passi durante l'uso Raypak 055B
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Raypak 055B
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Raypak 055B in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Raypak 055B?

Utilizza il modulo sottostante

Se non hai risolto il problema con Raypak 055B con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Raypak 055B è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)