  • Royal Gas Fire - page 1

    0102 095 50023 CLASS 2 – FLAME SYSTEM 3 USERS (Pages 2-3) / INST ALLATION (Pages 4-9) AND SERVI CING IN STRUCTIONS THIS CAT I 2H APPLIANCE IS FO R U SE ON NATURAL GAS G20 AT A SUPPL Y PRESSURE OF 20 mbar IN GB and IE HAND THESE INSTRUCTIONS TO THE USER ...

  • Royal Gas Fire - page 2

    USERS INSTRUCTIONS Descri ption This Royal Coz y Fires Decorativ e Fuel Effec t gas fire has been dev eloped to giv e a realistic coal burning appeara nce with the ins tant con trol and conv enienc e of g as. The fi re has be en construc ted to e nable it to be inst alled i nto most applic ations (using the op tiona l spac er fr ame) where the warm ...

  • Royal Gas Fire - page 3

    3. 0nce a pilot- flam e has been established; k eep the control depressed for a further 20 seconds. Release the gas control and check that the pilo t rem ains lit. 4. Depress the gas control s lightly and turn anti- clockwise until th e indicator m ark is aligned with the l etters HIG H. The burner will cross l ig ht from the pilot. 5. Depress the ...

  • Royal Gas Fire - page 4

    INSTALLATION INSTRUCTI ONS THE FOLLOWI NG SECTION LISTS THE INSTALLATIO N REQUIREMENTS AND REGULATI ONS A com petent pers on in ac cordance w ith th e curre nt Gas Saf ety (I nstalla tion and U se) Reg ulat ions or the rules in force and in accordanc e with th e m anufacturer ’ s ins tructions m ust install the appl iance; fa ilure to d o so coul ...

  • Royal Gas Fire - page 5

    Installing the Appliance Check that the ch im ney and flue structur e are sound and conform to th e following flue requir ements. a) A conven tional b rick or s tone chim ney with a m inim um effect ive cro ss section al dim ension o f 225 x 225m m. A lined flue with a m inim um diameter of 175m m having a chair brick and t hroat forming lintel con ...

  • Royal Gas Fire - page 6

    Installation us ing a 5 ” Diameter Met al Flue Box Important : The sp igot re stric tor m ark ed ’ B ’ must be fi tted. Se e page 7. When the m etal f lue box is to be bui lt- in as a false chim ney breast using the timber studwo rk with pla sterboard fac ing, the metal fl ue box shou ld be env eloped with insula tion m aterial such as Ro ckw ...

  • Royal Gas Fire - page 7

    The two slo ts in the r ear of the base of the fi rebox may be used to secure the appliance in posi tion. Where no space r is used the uni t will requ ire sec uring at the top u sing the two hole s in the top corner plate and the No 10 c/sk screw s provided. Th is is n eeded to ef fect a seal with the flu e. Vent Box Installed with Spacer frame a. ...

  • Royal Gas Fire - page 8

    Checking Op e rat ion of Fir e Turn on the gas supply at the meter and to th e appl iance a t the isol ating cock . Purge the air f rom the app liance. P re ss a nd turn the gas control an ti-clock wise, keep the control fu lly depressed. The igniter w ill opera te and the pilot will light, chec k that the e lectrod e is sp arking to the h ead of t ...

  • Royal Gas Fire - page 9

    Removal of Debr is or Soot De posits Debris from any source or any soot formed sha ll require removal . Allow the appl iance to cool suf ficien tly before remov ing all of t he coals and f ireb ed componen ts for cleaning purposes. Once all the ceram ics are rem oved from the firebed che ck that no debr is is loca ted in the burne r slots. I f any ...

  • Royal Gas Fire - page 10

    Page 10 ...

  • Royal Gas Fire - page 11

    Depth A is to be a minimum of 150mm from the knee to the front face of the surround with the sap cer fitted to satisfy the debris collec tion requirement Depth B is Nominally 70mm. If no chairbrick is fitted, the minimum distance re quired between the rear of the opening and the front face of the surround is 210mm without spacer frame fitted. Page ...

  • Royal Gas Fire - page 12

    Page 12 ...

  • Royal Gas Fire - page 13

    Page 13 ...

  • Royal Gas Fire - page 14

    Page 14 ...

  • Royal Gas Fire - page 15

    Page 15 ...

  • Royal Gas Fire - page 16

    Page 16 ...

  • Royal Gas Fire - page 17

    Page 17 ...

Fabbricante Royal Categoria Fire Pit

I documenti che otteniamo dal fabbricante del dispositivoRoyal Gas Fire possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Royal
- manuali per l’uso Gas Fire
- schede prodotto Royal
- opuscoli
- o etichette energetiche Royal Gas Fire
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Royal Gas Fire.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Royal Gas Fire, manuali di manutenzione, brevi manuali o manuali utente Royal Gas Fire. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Royal Gas Fire.

Manuali per l’uso simili

Manuale completo del dispositivo Royal Gas Fire, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Royal Gas Fire dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Royal Gas Fire.

Il manuale per l’uso completo Royal, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Royal Gas Fire - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Royal Gas Fire, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Royal Gas Fire che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Royal Gas Fire - che ci dovrebbe aiutare nei primi passi durante l'uso Royal Gas Fire
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Royal Gas Fire
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Royal Gas Fire in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Royal Gas Fire?

Utilizza il modulo sottostante

Se non hai risolto il problema con Royal Gas Fire con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Royal Gas Fire è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)