Manuale per l’uso Zephyr COK-E42SX

23 pagine 0.87 mb
Scarica

Vai alla pagina of 23

Summary
  • Zephyr COK-E42SX - page 1

    Okeanito C O K -E36SX C O K-E42SX C O K -E48SX U s e , C a r e , a n d I n s t a lla t ion G u id e MAY07.0101 ww w .zephyronline.com Model number: Serial number: Date of Purchase: Sales Dealer: © Zep hyr Corpo ration. ...

  • Zephyr COK-E42SX - page 2

    www .zephyronline.com ...

  • Zephyr COK-E42SX - page 3

    Ta b l e o f C o n t e n t s 1 SAFET Y NOTICE .............................................. LIST OF MA TERIALS ....................................... INST ALLA TION Ducting Calculation Sheet ............................... Mounting Height and Clearance ..................... Ducting ................................................................. ...

  • Zephyr COK-E42SX - page 4

    www .zephyronline.com Im p or tan t s afety N o t i c e 2 TO R E D U C E T H E R I S K O F F I R E O R E L E C T R IC SH OC K, D O N O T USE T H IS FAN W ITH ANY S O L ID- S T A TE SP E E D CONTRO L DE V I C E . TO R E DU C E T H E R IS K O F F I R E, E L E C T R I C SH O C K, O R INJ U R Y T O P E R S ON S, O B S E RVE T H E FO L LO W I N G: a. Us ...

  • Zephyr COK-E42SX - page 5

    Li s t of M a t e r ia l s 3 MODEL: COK-ExxS 1 - Hood 1 - Bae Filter (2 on 48” model) 2 - 50W 120V Halogen Light Bulbs G U-10 2 - 40W 120V Appliance Bulbs 1 - Utensil Rail 2 - T elescopic Duct Covers 1 - Ceiling Mounting Bracket (pre attac hed to duct cover) 1 - W all Mounting Bracket 1-H A R D W A R EP A C K E T 7 - 2” W ood Screws 7 - Anch ...

  • Zephyr COK-E42SX - page 6

    www .zephyronline.com 4 I ns t a lla t io n - Duct wo rk C a lcula t io n S he e t Duct pieces To t a l Equivalent number length x used = 31 / 4 ”x1 0 ” Rect., straight 1 F t. x ( ) = Ft. 7” Round, straight 1 Ft. x ( ) = Ft. 31 / 4 ”x1 0 ” Rect. 90 0 elbow 15 Ft. x ( ) = Ft. 31 / 4 ”x1 0 ” Rect. 45 0 elb ow 9 Ft. x ( ) = Ft. 31 / 4 ? ...

  • Zephyr COK-E42SX - page 7

    5 I ns t a l l a t i o n - M o unt i ng H e i ght & C l e a ra nc e DUC T I N G 36" M in 96"-Max 124 ” M in 28"-Max 36" Min 32"-Max 52" 14 1/2" Minimum mount height between range top to hood bot- tom should be no less than 28". Maximum mount height should be no higher than 36". It is important to i ...

  • Zephyr COK-E42SX - page 8

    Installation - Ducting www .zephyronline.com side wall cap with gravity damper Soffit or crawl space Roof Pitch w/ Flashing & Cap 6 Soffit or crawl space External Blower External Blower W ARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics, or garages. All exhaust must be ducted t ...

  • Zephyr COK-E42SX - page 9

    7 I n s t a lla tion - Sp ec ific at ion s R I H P E Z Y B N G I S E D G N E H C O G O L 19 3 / 4” 19 3/4” 10” 36” , 42” , 48 ” 22 5 / 8” 11 7 / 8” 95 ° 16 5/8” 13 3 / 8” 14 1 / 2” 15” 5" - 3 6 " 8" - 42" 31 / 2 " - 4 8 " 6" 9 3/16” ” 6 1 / 5 O 8 5/16” ” 8 / 1 4 R ” 2 3 / 1 1 4 R ...

  • Zephyr COK-E42SX - page 10

    www .zephyronline.com I ns t a lla t io n - In t e r n a l B l ow e r 8 The internal blower kit consists of the blower and capacitor box with wiring. 1. Position blower as shown. 2. Att ach blower to ange as shown using the provided 1/2” 5x15mm screws with washers. 3. P osition capacitor bo x as shown. 4. Secure capacitor bo x to hood using th ...

  • Zephyr COK-E42SX - page 11

    I n s t a lla tion - I n te r n al B lower 9 5. Remove existing grounding screw and att ach grounding wire from capacitor bo x. 6. Re-attach grounding screw to nish installation of capacitor box. Refer to Fig-A on previous page. 7 . Attach short capacitor connector to blower connector. 8. Att ach long capacitor connector to control board connect ...

  • Zephyr COK-E42SX - page 12

    www .zephyronline.com 10 I ns t a lla t io n - P re p a ring E xt e rn a l B lo we r The external blower kit consists of an 8” collar , and external blower wiring box. T he external blower is purchased separately . A T TE NTI O N The following are intructions on preparing your hood for installation with e xternal blower model CB E-1000. F or inst ...

  • Zephyr COK-E42SX - page 13

    11 6. Position cover onto external blower wiring box. 7 . Secure cover to box with provided screw . 8. Attach connector from external blower wiring bo x to control board box connector inside hood. 9. Attach grounding wire from external blower wiring bo x to grounding screw of the junction bo x. Refer on Fig-A in diagram below . 10. Final view of ex ...

  • Zephyr COK-E42SX - page 14

    A B min 28” max 36” C/L C/L 14 1/2” Duct Cover Ceiling Bracket 7 1/2” Attach screws to ceiling bracket C/L C 21” Duct Cover Ceiling Bracket www .zephyronline.com 1. Measure from cooking surface to hood bottom, level and mark line A. 2. Plum and mark center line. 3. Mark mounting height, line B (14 1/2” from line A). This is the top of t ...

  • Zephyr COK-E42SX - page 15

    13 In s t a l l a t i on - Mo u n t i n g H o o d gap between bracket and wall To p Bottom 1. Place wall brac ket on line C. P osition t o p of wall brac ket so it is even with the 21” mounting spread. Make sure bracket is atta c hed to wall as shown in the diagram. T he top of the wall bra c ket should have a gap between it and the wall. T he bo ...

  • Zephyr COK-E42SX - page 16

    www .zephyronline.com 14 I ns t a lla t io n - A t t a c hing U t e ns il R a il 1. Attac h utensil rail to hood canopy . A small hole has been pre-drilled into the canopy to provide a starting point to attach the rst utensil rail post. A fter the rst post is lined up with the hole, gently slide the rest of the rail onto the canopy . (note: b ...

  • Zephyr COK-E42SX - page 17

    15 2 3 4 6 1 5 The standard Baffle Filters are required to be cleaned frequently and as recommended in order to maintain blower efficiency . If improperly maintained, residue from cooking will sift through filters and cause damage to hood blowers and other sensitive components; and possibly clog duct work and create a fire hazard. Blower On/Off Dis ...

  • Zephyr COK-E42SX - page 18

    16 Filter Clean Reminder (Standard Bae Filters tted): A set of bae lters are tted by the factory . These Bae Filters are intended to lter out residue from cooking. T hey need not be replaced on a regular basis but are required to be kept clean. The Filter Clean Reminder function in the microprocessor will automatically indicate ...

  • Zephyr COK-E42SX - page 19

    17 M a i n t e n a n c e - C l e a n i n g S urface M aintenance : C l ean p eriodicall y w i t hh ot s oap y wate r a n d c l ean cotto n c l ot h . Do n ot use co rr os iv e o r ab r as iv e deter g en t , o r stee l woo l /scourin g p a ds whi c i i h will s cra t c h an d d amag e surface . F or h ea vi er so il use liquid de g rease r . A fte ...

  • Zephyr COK-E42SX - page 20

    18 Replacing Light Bulbs: CA UTION: Light bulbs become extremely hot when turned on. DO NO T tou c h bulbs until swit c hed o and cooled. T ouc hing hot bulbs may cause serious burns. Make sure all power is turned o and bulbs are not hot. Remove bulb by pressing both ends of the metal retaining clip togethe r , the light so c ket will now pro ...

  • Zephyr COK-E42SX - page 21

    19 T ro uble S ho o t ing After installation, the unit doesn’t work? Light works, but motor is not turning. The unit is vibrating. The motor is working, but the lights are not. The hood is not venting out properly . Filter is vibrating. After hood has been installed for a period of time, it stopped working. 1. The power source is not turned ON. 2 ...

  • Zephyr COK-E42SX - page 22

    20 www .zephyronline.com Part Desc r iption P art# Halogen Bulb G U-10, 120V, 50W Z0B-0020 Incadescent Bulb T29 127V 40 W Z0B-0003 Internal Blower, 600 cfm CBI-600 External Blower, 1000 cfm CBE-1000 Duct Cover Extension Kit Z1C-00OK Accessory Desc r iption P art# List of Parts and Accessories ...

  • Zephyr COK-E42SX - page 23

    www.zephyronline.com Warranty One Y ear Service Repair W arranty: F or one year from date of original purchase, we will provide free of charge, service lab or to repair any failed parts or components due to manufacturing defects. T wo Y ears Parts W arr anty: F or two years from date of original purchase, we will provide free of charge, nonconsumab ...

Fabbricante Zephyr Categoria Ventilation Hood

I documenti che otteniamo dal fabbricante del dispositivoZephyr COK-E42SX possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Zephyr
- manuali per l’uso COK-E42SX
- schede prodotto Zephyr
- opuscoli
- o etichette energetiche Zephyr COK-E42SX
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Zephyr COK-E42SX.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Zephyr COK-E42SX, manuali di manutenzione, brevi manuali o manuali utente Zephyr COK-E42SX. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Zephyr COK-E42SX.

Manuali per l’uso simili

Manuale completo del dispositivo Zephyr COK-E42SX, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Zephyr COK-E42SX dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Zephyr COK-E42SX.

Il manuale per l’uso completo Zephyr, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Zephyr COK-E42SX - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Zephyr COK-E42SX, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Zephyr COK-E42SX che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Zephyr COK-E42SX - che ci dovrebbe aiutare nei primi passi durante l'uso Zephyr COK-E42SX
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Zephyr COK-E42SX
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Zephyr COK-E42SX in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Zephyr COK-E42SX?

Utilizza il modulo sottostante

Se non hai risolto il problema con Zephyr COK-E42SX con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Zephyr COK-E42SX è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine