Manuale per l’uso Sanyo CL2432

17 pagine 0.42 mb
Scarica

Vai alla pagina of 17

Summary
  • Sanyo CL2432 - page 1

    Contents Page IMPORT ANT! Please Read Before Starting .................................. 1 1. GENERAL .......................................................... 2 1-1. T ools Required for Installation (not supplied) 1-2. Accessories Supplied with Indoor Unit 1-3. Optional Copper T ubing Kit 1-4. T ype of Copper T ube and Insulation Material 1-5. Fi ...

  • Sanyo CL2432 - page 2

    1 IMPORT ANT! Please Read Before Starting This air conditioning system meets strict safety and operat- ing standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently . For safe installation and trouble-free operation, you must: ● Carefully read this ins ...

  • Sanyo CL2432 - page 3

    2 1. General This booklet briefly outlines where and how to install the air conditioning system. Please read over the entire set of instructions for the indoor and outdoor units and make sure all accessory parts listed are with the system before beginning. 1-1. T ools Required for Installation (not supplied) 1. Standard screwdriver 2. Phillips head ...

  • Sanyo CL2432 - page 4

    3 1-6. Additional Materials Required for Installation 1. Refrigeration (armored) tape 2. Insulated staples or clamps for connecting wire (See local codes) 3. Putty 4. Refrigeration lubricant 5. Clamps or saddles to secure refrigerant tubing 2. Installation Site Selection 2-1. Indoor Unit A VOID: ● direct sunlight. ● nearby heat sources that may ...

  • Sanyo CL2432 - page 5

    4 2-2. Outdoor Unit A VOID: ● heat sources, exhaust fans, etc. (Fig. 4a) ● damp, humid or uneven locations. DO: ● choose a place as cool as possible. ● choose a place that is well ventilated. ● allow enough room around the unit for air intake/ exhaust and possible maintenance. (Fig. 4b) ● provide a solid base a minimum of 6 inches above ...

  • Sanyo CL2432 - page 6

    5 Indoor side Outdoor side Set screws f or transportation only Right-rear tubing (recommended) Right tubing Left-rear tubling Fig. 6 Fig. 7a Center of left-rear tubing hole Center of right-rear tubing hole Fig. 7b NOTE Hole should be made at a slight downward slant to the outdoor side. In case of left-rear or right-rear tubing Fig. 8 3. How to Inst ...

  • Sanyo CL2432 - page 7

    6 3-3. Install the Rear Panel on the W all Be sure to confirm that the wall is strong enough to sus- pend the unit. See either Item a) or b) below depending on the wall type. a) If Wooden W all (1) Attach the rear panel to the wall with the 10 screws provided. (Fig. 1 1) If you are not able to line up the holes in the rear panel with the beam locat ...

  • Sanyo CL2432 - page 8

    7 How to replace the grille (1) Close the flaps. (2) Reinstall the grille into the lower part while aligning its tabs on the upper part. (Fig. 15a) Insert the tabs in the slots and push the lower part of the grille back into position. (3) Press at each of the 5 tabs to completely close the grille. Make sure that the grille and frame are firmly fitt ...

  • Sanyo CL2432 - page 9

    8 3-7. Recommended Wire Length and Diameter Regulations on wiring diameter differ from locality to locality . For field wiring requirements, please refer to your local electrical codes. Carefully observe these regu- lations when carrying out the installation. T able 5 lists recommended wire lengths and diameters for power supply systems. Refer to t ...

  • Sanyo CL2432 - page 10

    9 3-8. Wiring Instructions for Inter-unit Connections (1) Insert the inter-unit wiring (according to local codes) into the through-the-wall PVC pipe. Run the wiring toward the indoor side allowing approx. 10 inch to extend from the wall face. (Fig. 19) (2) Route the inter-unit wiring from the back of the indoor unit and pull it toward the front for ...

  • Sanyo CL2432 - page 11

    10 When connecting each power wire to the corresponding terminal, follow the instructions “ How to connect wiring to the terminal ” and fasten the wire securely tight with the fixing screw of the terminal plate. How to connect wiring to the terminal ■ For solid core wiring (or F-cable) (1) Cut the wire end with a cutting pliers, then strip th ...

  • Sanyo CL2432 - page 12

    11 3-9. Mounting ■ Right-side tubing (1) Shape the refrigerant tubing so that it can easily go into the wall hole. (Fig. 24) (2) Push the wiring, refrigerant tubing, and drain hose through the hole in the wall. Adjust the indoor unit so it is securely seated on the rear panel. (3) Carefully bend the tubing (if necessary) to run along the wall in ...

  • Sanyo CL2432 - page 13

    12 3-10. Drain Hose a) The drain hose should be slanted downward to the outdoors. (Fig. 28) b) Never form a trap in the course of the hose. c) If the drain hose will run in the room, insulate the hose with insulation * so that chilled condensation will not damage furniture or floors. (Fig. 29) * Foamed polyethylene or its equivalent is recom- mende ...

  • Sanyo CL2432 - page 14

    13 4. Refrigerant T ubing 4-1. Indoor Unit T ubing ■ Rear-left tubing For rear-left tubing, optional tube connection (C) (APR- EN46U1B) is necessary . Please consult your nearest sales outlet or A/C workshop. 1. Make a 3-3/16" hole in the wall, centered on the crossing point between the triangle marks (A and B) on the rear panel. (Fig. 30a) ...

  • Sanyo CL2432 - page 15

    14 4-3. Connecting T ubing between Indoor and Outdoor Units a) T ightly connect the indoor side refrigerant tubing extended from the wall with the outdoor side tubing. (Fig. 33) b) T o fasten the flare nuts, apply specified torque as: T able 6 4-4. Insulation of Refrigerant T ubing (For C2432 and CL2432) T o prevent heat loss and wet floors due to ...

  • Sanyo CL2432 - page 16

    (2) Wrap the armoring tape from the bottom of the out- door unit to the top of the tubing where it enters the wall. As you wrap the tubing, overlap half of each previous tape turn. (Fig. 36) (3) Clamp the tubing bundle to the wall, using 1 clamp approx. every 4 ft. Do not wind the armoring tape too tightly since this will decrease the heat insulati ...

  • Sanyo CL2432 - page 17

    16 5. Remote Control Unit Installation Position The remote control unit can be operated from either a non-fixed position or a wall-mounted position. T o ensure that the air conditioner operates correctly , do not install the remote control unit in the following places: ● In direct sunlight ● Behind a curtain or other place where it is covered ? ...

Fabbricante Sanyo Categoria Air Conditioner

I documenti che otteniamo dal fabbricante del dispositivoSanyo CL2432 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Sanyo
- manuali per l’uso CL2432
- schede prodotto Sanyo
- opuscoli
- o etichette energetiche Sanyo CL2432
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Sanyo CL2432.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Sanyo CL2432, manuali di manutenzione, brevi manuali o manuali utente Sanyo CL2432. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Sanyo CL2432.

Manuali per l’uso simili

Manuale completo del dispositivo Sanyo CL2432, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Sanyo CL2432 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Sanyo CL2432.

Il manuale per l’uso completo Sanyo, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Sanyo CL2432 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Sanyo CL2432, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Sanyo CL2432 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Sanyo CL2432 - che ci dovrebbe aiutare nei primi passi durante l'uso Sanyo CL2432
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Sanyo CL2432
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Sanyo CL2432 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Sanyo CL2432?

Utilizza il modulo sottostante

Se non hai risolto il problema con Sanyo CL2432 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Sanyo CL2432 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)