    T igerSwitch 10/100 24-P ort 10/100 Managed Lay er 3 Switch ◆ 24 10B ASE-T/100B ASE-TX auto MDI/MDI-X ports ◆ Optional 1000B ASE-X or 100 B ASE -FX mo dules ◆ IP routing with RIP an d OSPF ◆ 8.8 Gbps of agg re gate bandwi dth ◆ Non-blocking switching architecture ◆ Spanning T ree Protocol ◆ Up to six LA CP or stati c 4-port trunks ◆ ...

  • SMC Networks SMC6724L3 INT - page 2

    ...

  • SMC Networks SMC6724L3 INT - page 3

    38 T e sla Irvine, CA 9261 8 Phone: (9 49) 679-80 00 T igerSwitch 10/100 Installation Guide From SM C’ s T iger line of f eature-rich w orkgroup LAN solut ions November 2003 Pub. # 15 020003 3800A ...

  • SMC Networks SMC6724L3 INT - page 4

    Infor matio n furnish ed by SMC Networks , Inc . (SMC) is believed to be accurate and reliable. Ho wever , no responsibility is assumed by SMC for its use, nor f or any in fring ement s of pa tents or oth er righ ts of thir d par ties which may result from its use. No license is g ranted by implicatio n or other wise und er an y pate nt or pate nt ...

  • SMC Networks SMC6724L3 INT - page 5

    i L IMITED W ARRANTY Limite d W arranty Sta tement: SMC N etworks, Inc. (“SMC” ) war rants its produ cts to be free from defects in work manship and materials , under nor mal use and service, for the applicable warranty term . All SMC products carry a standard 90-da y limited warranty from the date of purc hase from SMC or its A uthorized R ese ...

  • SMC Networks SMC6724L3 INT - page 6

    ii W ARRANTIES EX CLUSIVE: IF AN SMC PRODUCT DOES NOT OPERA TE AS W ARRANTED ABO VE, CUSTOMER’ S SOLE REMED Y SHALL BE REP AIR OR REPLA CEMENT OF THE P RODUCT IN Q UESTION , AT SMC’S OPTI ON . THE FOREGOING W ARRANTIE S AND REMEDIES ARE EXCL USIVE AND ARE IN LIEU OF ALL OTHER W ARRANTIES OR CONDITIONS, EXPRESS OR IMPLI ED , EITHER IN F A CT OR ...

  • SMC Networks SMC6724L3 INT - page 7

    iii C OMPLIANCES FCC - Class A This eq uipment ge nerates , uses , an d can radi ate radio fr equency energy and, if no t installed an d used in acco rdance wit h the inst r uction manual, may cause interf erence to radio communica tions. It has been tes ted and found to comply with the li mits for a Class A computi ng device pur suant to Subpar t ...

  • SMC Networks SMC6724L3 INT - page 8

    C OMPLIANCES iv EC Confor mance Declaration - Class A SMC contact f or thes e products in E urope is : SMC Networks Europe, Edifici o Conata II , Ca lle F ructuós Gela bert 6-8, 2 o , 4 a , 08970 - Sant Joan Despí, Barcel ona, Spai n. This i nfor mation technolog y equi pment compli es with the r equirements of the Counci l Directive 89/336 /EEC ...

  • SMC Networks SMC6724L3 INT - page 9

    C OMPLIANCES v Ja p a n V C C I C l a s s A Australia AS/NZS 3548 (1995) - Class A SMC contact f or product s in Austra lia i s: SM C Comm uni cation s Pty . Ltd. Suite 18, 12 T ryon R oad, Lindf ield NSW 2070, Phon e: 61-2- 94160437 F ax: 61-2- 94160474 ...

  • SMC Networks SMC6724L3 INT - page 10

    C OMPLIANCES vi Safety Compliance W a rni ng : F i b er O pt i c P ort S af e t y A vertissment : P orts pour fibres optiques - sé curité sur le plan optique W ar nhinw eis: F asero ptikansc hlüsse - O ptisc he Sic herheit Underwriter s Laborato ries Compli ance Statem ent Important! Before makin g connectio ns, make sure you have the corre ct c ...

  • SMC Networks SMC6724L3 INT - page 11

    C OMPLIANCES vii Wic htige Sich erheitshinw eise (Ger many) 1. Bitte le sen Sie die se Hinweise s orgfält ig durch. 2. Heben Sie diese Anleit ung für den spätere n Gebrauch auf. 3. V or jed em Reinigen i st das Gerät vom Stromnetz zu tre nnen. V erwenden Sie kei ne Flüssig oder Aerosolrei nig er. Am besten ei gnet sich ei n angef euchtetes Tuc ...

  • SMC Networks SMC6724L3 INT - page 12

    C OMPLIANCES viii ...

  • SMC Networks SMC6724L3 INT - page 13

    vii T ABLE OF C ONTENTS 1 About the TigerSwitch 10/100 . . . . . . . . . . . . . . . . . . . . . . 1-1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Switch Ar chitectur e . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Managem ent Option s . . . . . . . . . ...

  • SMC Networks SMC6724L3 INT - page 14

    T ABLE OF C ONTENTS viii 3 Installing the Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 Selecting a Site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 Equipm ent Checklis t . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 Package Con tents ...

  • SMC Networks SMC6724L3 INT - page 15

    T ABLE OF C ONTENTS ix A PPENDICES : A Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 Diagnosing Sw itch Indic ators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 Power and C ooling Prob lems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2 Installat ion . . . . . . ...

  • SMC Networks SMC6724L3 INT - page 16

    T ABLE OF C ONTENTS x ...

  • SMC Networks SMC6724L3 INT - page 17

    1-1 C HAPTER 1 A BOUT THE T IGER S WITCH 10/100 Overview SMC’ s TigerSwit ch 10/100 (SMC6724L3) is an intelligent multilayer switch with 24 10/100BASE-TX ports plus two slots on the front panel for slide-in modules (100B ASE-FX, 1000B ASE-T , or GBIC transceivers). There is als o an SNMP-based management agent emb edded on the main board. This ag ...

  • SMC Networks SMC6724L3 INT - page 18

    A BOUT THE T IGE R S WITCH 10/1 00 1-2 Figure 1-1. SMC6724L3 Front and Rear Panels Switch Architecture Th e switch em ploys a wire-spee d, non-b locking sw itching fabr ic. This per mits simultaneous w ire-speed tran spor t of multiple packets at low latency on all port s . This swit ch also features full-duplex capability on all ports , whi ch eff ...

  • SMC Networks SMC6724L3 INT - page 19

    O VER VIEW 1-3 Management Options This switch con tains a compreh ensiv e array of LE Ds for “at-a-glanc e” monit oring of netw ork a nd port statu s . It al so incl udes a ma nagement agent that allows you to configure or monitor the switch using its embed ded m anag ement soft ware, or v ia SN MP ap plicatio ns. T o manag e the s witch, you c ...

  • SMC Networks SMC6724L3 INT - page 20

    A BOUT THE T IGE R S WITCH 10/1 00 1-4 Description of Hardware RJ-45 P orts The switch base unit contains 24 10B ASE-T/100B ASE-TX RJ-45 ports. All of these p orts support automa tic MDI /MDI-X opera tion, s o you can use st raight-t hrough cabl es for a ll netw ork connecti ons to PCs or servers , or to other switches or hubs . (See “10BASE-T/10 ...

  • SMC Networks SMC6724L3 INT - page 21

    D ESCRIPTION OF H ARDW ARE 1-5 Ports Stat us LEDs The LEDs , whi ch ar e located o n the fr ont panel for easy viewing, are shown below and descri bed in the following ta ble. Figure 1-2. Port Status LEDs Port and Stat us LED s LED Condition Status Base Unit Ports Link On Green Port has esta blished a val id 100 Mbps network connection. Flashing Gr ...

  • SMC Networks SMC6724L3 INT - page 22

    A BOUT THE T IGE R S WITCH 10/1 00 1-6 System Status LEDs Figure 1-3. System Status LEDs System Status LEDs LED Condition Status PWR On Switch is receiving power. Off Power off or failure. RPU On The redundant powe r supply is ope rating normally. On Amber The redu ndant powe r supply has faile d. Off No redunda nt power supply is connect ed. Diag ...

  • SMC Networks SMC6724L3 INT - page 23

    D ESCRIPTION OF H ARDW ARE 1-7 Optional Media Extender Modules Optional 10/100/1000BA SE-T Module (SMC6824GT) Figure 1-4. Single-Por t 1000BASE-T Gigabit Module Using Categor y 5, 5e , or 6 twis ted-pair cab le y ou can connect to another device up to 100 m (328 ft) aw ay . Th e 1000B ASE-T module operates at 10/100/1000 Mbps . At 1000 Mbps it oper ...

  • SMC Networks SMC6724L3 INT - page 24

    A BOUT THE T IGE R S WITCH 10/1 00 1-8 Optional 100BASE-FX Module (SMC6824 FMSC) Figure 1-6. Single-Port 100BASE -FX Multimode Module Using multimode fiber optic cable, th e 100BASE-FX port can be connected to a remote site up to 2 km (1.24 miles) awa y . The 100B ASE-FX module is fix ed to operate at 100 Mbps full duplex, and suppor ts auto-neg ot ...

  • SMC Networks SMC6724L3 INT - page 25

    D ESCRIPTION OF H ARDW ARE 1-9 connection. This port can be connected to a site up to 5 km (16404 ft) away with sing le-mode fiber c able. 1000B ASE-ZX GBIC transceive rs provide one long-wa velength (1550 nm) Gig abit port that can be used for a long-haul connection to a remote lo cation. This port can be conn ected to a site up to 100 km (62.1 mi ...

  • SMC Networks SMC6724L3 INT - page 26

    A BOUT THE T IGE R S WITCH 10/1 00 1-10 Features and Benefits Connectivity ◆ 24 dual -speed ports fo r easy Fast Et hernet in tegrat ion and fo r prote ction of your inv estmen t in legacy LAN equ ipmen t. ◆ Auto-neg otiation enables ea ch RJ-45 port t o automati cally selec t the optimum communic ation mode (half or full duple x) if this featu ...

  • SMC Networks SMC6724L3 INT - page 27

    F EATURES AND B ENEFITS 1-11 Performance ◆ Transparent bridging ◆ Aggre gate bandw idth of up to 8.8 G bps ◆ Switching table with a total of 8K MAC addr ess entrie s and 2K IP address en tries ◆ Provides store-and-forward switchin g for intra-VLAN traffic, and IP routing for in ter-VLAN traffic ◆ Support s wire-speed switching at Laye r 2 ...

  • SMC Networks SMC6724L3 INT - page 28

    A BOUT THE T IGE R S WITCH 10/1 00 1-12 ...

  • SMC Networks SMC6724L3 INT - page 29

    2-1 C HAPTER 2 N ETWORK P LANNING Introduction to Switching A network switch allows s imultaneous transmissio n of multiple packe ts via non-cros sbar switching . Th is means that it can par tition a netw ork more effici ently th an bridges o r routers . The switc h has , the refore, b een recogniz ed as one of the mo st impo rtan t building blocks ...

  • SMC Networks SMC6724L3 INT - page 30

    N ETWORK P LANNING 2-2 Application Examples The Tig erSwitch 10/100 is not only designed to segment your netw ork, but also to provide a wide ran ge of opti ons in set ting up network connect ions. Some typical ap plications a re descr ibed below . Collapsed Backbone The T igerSwitch 10/100 is an excellen t choice for mixed Ethernet an d Fa st Ethe ...

  • SMC Networks SMC6724L3 INT - page 31

    A PPL ICAT ION E XAM PLES 2-3 Centra l Wiri ng Clos et With 26 parallel bridgin g ports (i.e., 26 distinct collision dom ains), this switch can co llapse a complex n etwork down into a sing le efficient bridged node, incr easin g overall bandwi dth and throu ghput. In the figure below , the 10B ASE-T/100B ASE-TX ports on the switch are providing 10 ...

  • SMC Networks SMC6724L3 INT - page 32

    N ETWORK P LANNING 2-4 Remote Connection with Fiber Cable Fiber op tic t echnolog y allows f or long er ca bling tha n any o ther me dia ty pe. A 100 Mbps multimode fiber (MMF) link can ru n up to 2 km, and a 100 Mbps single-mode fiber (SMF) link can r un as far as 20 km. A 1000B ASE-SX (MMF) link can connect to a site up to 550 meters aw ay , and ...

  • SMC Networks SMC6724L3 INT - page 33

    A PPL ICAT ION E XAM PLES 2-5 Making VLAN Connections VLANs c an be based on untag ged port groups , or each data f rame can b e explicitly tag ged to identify the VLAN g roup it belongs to . When usi ng port-based VLANs , ports ca n either b e assign ed to o ne specific g roup or to all g roups . P or t-based VLANs are suitable for small networks ...

  • SMC Networks SMC6724L3 INT - page 34

    N ETWORK P LANNING 2-6 Using Layer 3 Routing VLAN s can si gnifica ntly en hance netw ork performance an d securi ty . Ho wev er , if y ou use con v ention al routers to inter connect VLANs , y ou can lose most of your pe rfor mance advantage . T he TigerSwitch 10/100 provides wire-speed routing, which allows you to eliminate your conventional I P ...

  • SMC Networks SMC6724L3 INT - page 35

    C ONNECTIVITY R ULES 2-7 Connectivity Rules When addi ng hubs (repeat ers) to your ne tw ork, p lease follo w the s tandard conne ctivity r ule s for Et hern et or Fast Ethe r net. H ow ever, note that because switc hes break up t he path fo r connecte d devices into separa te collision d omains, y ou sho uld not include the switch or con nected ca ...

  • SMC Networks SMC6724L3 INT - page 36

    N ETWORK P LANNING 2-8 10/100 Mbps Ethernet Collision Domain Maximum 10/1 00 Mbps Ethernet Cab le Distance Type Cable Type Max. Cabl e Length 10BASE-T Twisted Pair, Category 3 or better 100 m (328 ft) 100BASE-TX Category 5 o r better 10 0-ohm UTP or STP 100 m (328 ft) 100BASE-FX Multimode 50/125 or 62.5/125 micron core multimode fiber (MMF) 2 km (1 ...

  • SMC Networks SMC6724L3 INT - page 37

    A PP LIC ATIO N N OTES 2-9 Application Notes 1. Full-duplex operation on ly applies to point -to-point access (such as when a switc h is attac hed to a w orkstation, ser ver or a nother switc h). When the switc h is con nected t o a hub , both devi ces mu st opera te in half-duplex mode. 2. A void u sing fl ow control o n a por t connec ted to a hu ...

  • SMC Networks SMC6724L3 INT - page 38

    N ETWORK P LANNING 2-10 ...

  • SMC Networks SMC6724L3 INT - page 39

    3-1 C HAPTER 3 I NSTALLING THE S WITCH Selecting a Site TigerSwitch 10/100 units can be mounted in a standard 19-inc h equipment rack or on a flat surface. Be sure to follo w the guideline s below when c hoosing a location . ◆ The site should: • be at the center of al l the devic es you want to link and n ear a power outlet. • be able to main ...

  • SMC Networks SMC6724L3 INT - page 40

    I NS TAL LI NG THE S WITCH 3-2 Equipment Checkli st After unpacking the TigerSwitch 10/100, chec k the contents to be sure you h av e recei v ed all t he compon ents . Then, before beg innin g the installation, be sure you hav e all othe r necessar y installation equipmen t. Package Contents ◆ TigerSwitch 10/100 unit, SMC6724L3 ◆ Four adhes ive ...

  • SMC Networks SMC6724L3 INT - page 41

    M OUNTING 3-3 Mounting A TigerSwitch 10/100 unit can be mounted in a standard 19-inch equipmen t rac k or on a d esktop o r shelf . Moun ting ins tr uctions for ea ch type of si te follow . Installin g Optional Modu les : Before mou nting the switch, be sur e you install any optio nal modules . If you hav e purchased optional slide -in 1000B ASE-T ...

  • SMC Networks SMC6724L3 INT - page 42

    I NS TAL LI NG THE S WITCH 3-4 T o rack-mou nt dev ices: 1. Attac h th e brack ets t o the devi ce using t he screws provi ded in th e Bracket Mounting K it. Figure 3-1. Attaching the B rackets 2. Mount the device in the r ack, using four rack-mount ing screws (not provided ). Figure 3-2. In stalling the Switch in a Rack 3. If installing a single s ...

  • SMC Networks SMC6724L3 INT - page 43

    M OUNTING 3-5 Desktop or Shelf Mountin g 1. Attach the fou r adhesive feet to the b ottom of the first swit ch. Figure 3-3. Att aching th e Adhesive Feet 2. Set the device on a flat surface near an A C po wer s ource , making sure there are a t least two inches of sp ace on all side s for p roper air f low . 3. If installing a single switch only , ...

  • SMC Networks SMC6724L3 INT - page 44

    I NS TAL LI NG THE S WITCH 3-6 Installing an Optional Module into the Switch Figure 3-4. Installing an Optional Module Caution: DO NOT install slide- in modules wi th the switc h powered on . Be sure you power off the switch be fore installing any module. T o install an option al module into the switch, do the following: 1. Dis connect pow er to th ...

  • SMC Networks SMC6724L3 INT - page 45

    I NSTALLING A GBIC T RANSCE I VER 3-7 Installing a GBIC Transceiv er Figure 3-5. Installing a GBIC Transceiver Y ou can install a GBIC transcei ve r as described below: 1. Insert th e transc eiv er with the SC conn ector fac ing out t owa rd y ou. Note th at the trans ceive r is keyed so that it ca n only b e installed in on e orient ation . 2. Pre ...

  • SMC Networks SMC6724L3 INT - page 46

    I NS TAL LI NG THE S WITCH 3-8 Connecting to a Power Source T o conn ect a device to a po wer source: 1. Insert th e pow er cable pl ug direc tly into th e receptacle l ocated at the back of th e de vice. Figure 3-6. Pow er Receptacle 2. Plug t he other e nd of th e cable in to a grounded, 3-pi n sock et. Note: For Internati onal use, yo u may ne e ...

  • SMC Networks SMC6724L3 INT - page 47

    4-1 C HAPTER 4 M AKING N ETWORK C ONNECTI ONS Connecting Network Devices The Tig erSwitch 10/100 may be c onnected to 10 or 100 Mbps network cards in PCs and servers , as we ll as to hubs and s witches . It may also be connect ed to remote devices u sing the optio nal fiber optic modules Twisted-Pair De vices Each device requires a shielded or unsh ...

  • SMC Networks SMC6724L3 INT - page 48

    M AKIN G N ETWORK C ONNECTIONS 4-2 MDI-X port using straigh t-throug h cable . T o connec t betw een tw o switc hes/hu bs that only hav e fix ed MDI-X ports , the wiring crosso v er mus t be impl emented in the cabl e - kno wn as a cros sov er cabl e. The RJ- 45 ports o n the swi tch base uni t supp ort automati c MDI/MD I-X operation, which means ...

  • SMC Networks SMC6724L3 INT - page 49

    T WISTED -P AIR D EVIC ES 4-3 2. If the device is a PC c ard and the switc h is in th e wiring clo set, attac h the ot her end of t he cabl e segment t o a modul ar wall outlet that is connec ted to th e wiring closet. (See “W iring Clo set Con nections ” on the ne xt page .) Oth erwise , attac h the ot her end to an a va ilable port on the s w ...

  • SMC Networks SMC6724L3 INT - page 50

    M AKIN G N ETWORK C ONNECTIONS 4-4 Wiring Closet Connections T oda y , the punc h-do wn bloc k is a n integral part of many of t he newe r equip ment racks. It is actually par t of th e patch pan el. Instr u ctions for making connec tion s in the wir ing clo set wi th this ty pe of eq uipme nt follows . 1. Atta ch one en d of a p atch cable to an a ...

  • SMC Networks SMC6724L3 INT - page 51

    F IBE R O PTIC D EVIC ES 4-5 Fiber Optic Devi ces An optional slide-in 100B ASE-FX module ma y be used for backbone or long-distance connections . The 1000BASE-X slide-in GBIC support module may be used in conjunction with a 1000BASE-SX, 100B ASE-LX, or 1000B ASE-ZX GBIC transcei ver for h igh-speed and long-distance connections from 550 meters to ...

  • SMC Networks SMC6724L3 INT - page 52

    M AKIN G N ETWORK C ONNECTIONS 4-6 3. Connect one end o f the cab le to the SC p ort on the swi tch and the other end to t he SC port on the other de vice . Since SC connect ors are ke yed, the cab le can be attac hed in on ly one or ientatio n. Figure 4-3. Making SC Port Connections 4. As a c onnectio n is mad e, c heck t he Acti vity LED on the s ...

  • SMC Networks SMC6724L3 INT - page 53

    A-1 A PPENDIX A T ROUBLESHOOTING Diagnosing Switch Indicators Troubles hooting Cha rt Symptom Action PWR LED is Off • In ternal power sup ply has failed or is dis connected . • Check connection s between the switch, the power cord, and the wall ou tlet. • Contact SMC Technic al Support. Link LED is Off • V erify that the switch and attache ...

  • SMC Networks SMC6724L3 INT - page 54

    T R OUBLESHOOTING A-2 Power and Cooling Problems If the power indi cator doe s not tur n on when the power co rd is plug ge d in, you may have a problem with t he power out let or DC power adapter. Howev er, if the unit powers off after r unning for a while, check for loose power connections , power losses or surges at the pow er outlet. If you sti ...

  • SMC Networks SMC6724L3 INT - page 55

    B-1 A PPENDIX B C ABLES Specificati ons Cable Types and Specific ations Cable T ype Max. Len gth Connect or 10BASE-T Cat. 3 or better 100-ohm UTP 100 m (328 ft) RJ-45 100BASE-TX Cat 5 or better 100-ohm UTP 100 m (328 ft) RJ-45 100BASE-FX 50/125 or 62.5/125 micron core multimode fiber (MMF) 2 km (1.24 miles) SC or SC-ST 100BASE-FX 9/125 micron core ...

  • SMC Networks SMC6724L3 INT - page 56

    C ABL ES B-2 Note: If you need t o connect to a device w ith 62.5/125 micr on cable t hat has ST- type conn ector s, SMC p rovi des an optio nal S C-ST Converter (Part Number: 99-012034-091). Twisted-Pair Cable and Pin Assignments Caution: DO N OT plug a phone jac k connect or into any RJ-45 port. Use only twisted-pai r cables with RJ-45 con nector ...

  • SMC Networks SMC6724L3 INT - page 57

    T WISTED -P AIR C ABL E AND P IN A SSIGNMENTS B-3 10BASE-T/100BASE -TX Pin Assignments Figure B- 1. RJ-4 5 Connector Pin Numb ers Use unshielde d twisted-pair (UTP) or s hielded twiste d-pair (STP) cable for RJ-45 connections: 100-ohm Categ or y 3, 4 or 5 cable for 10 Mbps connections or 100-ohm Categor y 5 cable for 100 Mbps connections . Also be ...

  • SMC Networks SMC6724L3 INT - page 58

    C ABL ES B-4 Straight-Through Wiring If the twiste d-pair cable is to jo in two ports and only one of the p orts h as an inter nal cr ossover (MDI-X), th e two pairs of wires must be strai ght-thr ough. ( When a uto-nego tiatio n is en abled f or any R J-45 po rt on this s witch, you can use ei ther str aight-th rough or crossover cable to connec t ...

  • SMC Networks SMC6724L3 INT - page 59

    T WISTED -P AIR C ABL E AND P IN A SSIGNMENTS B-5 1000BASE-T Pin Assignments All 1000B ASE-T ports support automati c MDI/MDI-X operation, so y ou can use strai ght-t hrough cabl es for all netw or k connection s to PCs or servers , or t o othe r switch es or hub s . The table below shows the 1000B ASE-T MDI and MDI-X port p inouts . Th ese po rt s ...

  • SMC Networks SMC6724L3 INT - page 60

    C ABL ES B-6 1000BASE-T Cable Requirements All Catego ry 5 UTP cables that are used for 100B ASE-TX connections should also wo rk for 1000B ASE-T , providing that all four wire pairs are connected. Howev er, it is recommende d that for all cr itical connectio ns , or any new cable instal lations , Categ ory 5e (enhanced Categ ory 5) or 6 cable shou ...

  • SMC Networks SMC6724L3 INT - page 61

    C ONSOLE P ORT P IN A SSIGNMENTS B-7 Console Port Pin Assignments The DB-9 seria l port on the swit ch’ s front pan el is used t o connect to the switch for out-of -band consol e config uratio n. T he on -board me nu-driven config uration p rog ram ca n be acc essed from a ter m inal or a PC r u nning a ter m inal emulatio n prog r am. Th e pin a ...

  • SMC Networks SMC6724L3 INT - page 62

    C ABL ES B-8 The serial port’ s configur ation requir ements are as fo llows: • Default Baud rate—9,600 Bps. •P a r i t y — N o n e . •S t o p b i t — O n e . • Data bits—8. ...

  • SMC Networks SMC6724L3 INT - page 63

    C-1 A PPENDIX C S PECIFI CATIO NS Physical Characteristics Base Uni t Po r t s 24 10B ASE-T/100BAS E-TX , with auto-negotiatio n Media Slot 2 slots for optional 100BASE-FX, 1000B ASE-T and 1000B ASE-X (GBIC) Network Interface 10B ASE-T: RJ-45 (100-ohm, UTP cable; Categ ories 3, 4, 5) 100B ASE-TX: RJ-45 (100-ohm , UTP cable; Categor y 5) P orts 1-24 ...

  • SMC Networks SMC6724L3 INT - page 64

    S PECI FIC ATIO NS C-2 LEDs System: PWR, RPU , Diag Po r t : Lin k/Acti vity We i g h t 5.0 kg (11.02 oz) Size 44.0 x 41.0 x 4.4 cm (17.4 x 17.3 x 1.7 in.) Te m p e r a t u r e Operating: 0 to 50 ° C (32 to 122 ° F) Storage: -4 0 to 70 ° C (-40 to 158 ° F) Humidit y Operating: 5% to 95% Pow e r S u p p l y Internal, aut o-ranging transfor mer : ...

  • SMC Networks SMC6724L3 INT - page 65

    W AR RANTY C-3 Immunit y EN 61000-4-2/3/4/5/6/8/11 Safety CSA/NRTL (CSA 22.2.950 & UL 1950) EN60950 (TÜV/GS) Warranty Limited Li fetime Slide-in Modu les 100BASE-FX Extender Modules Model s SMC6824FSSC, SMC6824FMSC Po r t s 1 100B ASE-FX, SC connectors Communication Spe ed 100 Mbps Communication Mo de Full duplex Network Interface SMC6824FSSC ...

  • SMC Networks SMC6724L3 INT - page 66

    S PECI FIC ATIO NS C-4 We i g h t 50 g (1.8 oz) Size 11.0 x 7.3 cm (4.3 x 2.87 in.) 1000BASE-T Extender Module Model SMC6824GT Po r t s 1 10000B ASE-T , RJ-45 connector Communication Spe ed 10/100/1000 Mbps Communication Mo de Full duplex only at 1000 Mbps Full and half dup lex at 10/100 Mbps Network Interface RJ-45 (100-ohm, UTP cable; Categor y 5 ...

  • SMC Networks SMC6724L3 INT - page 67

    S LID E - IN M ODULES C-5 1000BASE-X GBIC Module Model SMC6824GB Po r t s 1 slot for GBI C transce iv ers Communication Spe ed 1000 Mbps Communication Mo de Full Duplex Standards IEEE 802.3z Gig abit Ether net We i g h t 70 g (2.5 oz) Size 11.0 x 7.3 cm (4.3 x 2.87 in.) ...

  • SMC Networks SMC6724L3 INT - page 68

    S PECI FIC ATIO NS C-6 ...

  • SMC Networks SMC6724L3 INT - page 69

    D-1 A PPENDIX D O RDERING I NFORMATION TigerSwitch 10/1 00 Products and Acc essories Product Number Description SMC6724L3 24-port Layer 3 switch with two media expa nsion slots SMC6824GT Gigabit module with one 10/100/ 1000BASE-T port (RJ-45 connector) SMC6824FSSC Extender module with one 100BASE-FX single-mode fiber port (SC-type conne ctor) SMC68 ...

  • SMC Networks SMC6724L3 INT - page 70

    O RDERING I NFOR MATION D-2 ...

  • SMC Networks SMC6724L3 INT - page 71

    Glossary-1 G LOSSA RY 10BASE-T IEEE 802.3 specification for 10 Mbps Ethernet ov er two pairs of Categor y 3, 4, or 5 UTP cable . 100BASE-TX IEEE 802.3u specification for 100 Mbps F ast Ethernet over tw o pairs of Categor y 5 UTP cable . 100BASE-FX IEEE 802.3u specification for 100 Mbps F ast Ether net o ver tw o strands of 50/125 or 62.5/125 micron ...

  • SMC Networks SMC6724L3 INT - page 72

    Glossary-2 Auto-N egot iation Signalli ng method allowing each no de to se lect its o ptimum oper ational mode (e .g ., 10, 100, or 1000 Mbps and half or full duplex) based on the capabilities of th e node to which it is conn ected. Bandwidth The differ ence betw een th e highes t and l owe st frequenc ies a va ilable f or network signals. Also sy ...

  • SMC Networks SMC6724L3 INT - page 73

    Glossary-3 Fast Ethernet A 100 Mbps network comm unication system based on Ethernet and the CSMA/CD access method. Fast Ethernet Switch Device that provide s a full 100 Mbps bandwidth (or either 10 or 100 Mb ps band width wit h Aut o-Negotiati on) to eac h port (LAN segmen t). Full Duplex T ransmission method that allows switch and net work car d t ...

  • SMC Networks SMC6724L3 INT - page 74

    Glossary-4 IEEE 802.3z Defines CSMA/CD access method a nd phy sical la yer sp ecifications for 1000BASE Gigabit E thernet. LAN Segment Separate LAN or co llision domain. LED Light emittin g diode u sed for monito ring a de vice or network cond ition. Link Segm ent Length of twist ed-pair or fibe r cabl e joining a pair of r epe aters or a repeater ...

  • SMC Networks SMC6724L3 INT - page 75

    Glossary-5 RJ-45 Connector A conn ector fo r twiste d-pai r wiring . Straight -throug h Port An RJ-45 po r t whic h does n ot cross t he recei v e and trans mit signals inter nally so it can be conne cted with s traight-throu gh twiste d-pair cable to any device having a cr ossov er port. Also referred to as a “Daisy-Chain” por t. Switched Po r ...

  • SMC Networks SMC6724L3 INT - page 76

    Glossary-6 ...

  • SMC Networks SMC6724L3 INT - page 77

    Index-1 Numerics 10 Mbps connect ivity rules 2-9 10/100 Mbps connec tivity rules 2-8 10/100/1000BASE -T modules 1-7 1000 Mbps connectivity rules 2-7 1000BASE-LX connections 4-5 fiber cable le ngths 2-7 1000BASE-SX connections 4-5 fiber cable le ngths 2-7 modules 1-8 1000BASE-T cable lengths 2-7 1000BASE-X modules 1-8 100BASE-FX connections 4-5 fibe ...

  • SMC Networks SMC6724L3 INT - page 78

    I NDE X Index-2 F features management 1-11 switch 1-10 fiber cables 4-5 front and rear panels of switch 1- 2 full-duplex co nnectivity 2-1 G Gigabit Et hernet cable lengths 2 -7 grounding f or racks 3-3 I indicators, LED 1-5 installation connecting devi ces to the switch 4-2 desktop or she lf mounting 3- 5 installing a GBIC transce iver 3-7 install ...

  • SMC Networks SMC6724L3 INT - page 79

    I NDEX Index-3 console port B- 7 DB-9 B-7 port-base d VLANs 2- 5 ports, connec ting to 4-1 , 4-5 power, connec ting t o 3-8 problems, trou bleshooting A-1 R rack mounting 3-3 rear panel recept acles 1-9 RJ-45 port connections 4-1 RJ-45 ports 1 -4 rubber foot pads, at taching 3-5 S SC port connection s 4-5 screws for rack mounting 3-2 SC-ST Conve rt ...

  • SMC Networks SMC6724L3 INT - page 80

    I NDE X Index-4 ...

  • SMC Networks SMC6724L3 INT - page 81

    ...

  • SMC Networks SMC6724L3 INT - page 82

    38 T es la Irvine, CA 92618 Phone: (9 49) 679-8000 Model Number : SMC6724L3 Pub. Number: 15 0200033 800A E1 12003-R 01 FOR TECHNICAL SUPPOR T , CALL: From U.S.A. an d Canada (2 4 hours a day , 7 days a week) (800) SMC-4-YOU; Phn: (949) 679-800 0; Fax: (949) 679-1 481 From Europ e : Contact deta ils can be foun d on www .smc-e urope.com or w ww . sm ...

Fabbricante SMC Networks Categoria Switch

I documenti che otteniamo dal fabbricante del dispositivoSMC Networks SMC6724L3 INT possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici SMC Networks
- manuali per l’uso SMC6724L3 INT
- schede prodotto SMC Networks
- opuscoli
- o etichette energetiche SMC Networks SMC6724L3 INT
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso SMC Networks SMC6724L3 INT.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione SMC Networks SMC6724L3 INT, manuali di manutenzione, brevi manuali o manuali utente SMC Networks SMC6724L3 INT. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto SMC Networks SMC6724L3 INT.

Manuali per l’uso simili

Manuale completo del dispositivo SMC Networks SMC6724L3 INT, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare SMC Networks SMC6724L3 INT dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti SMC Networks SMC6724L3 INT.

Il manuale per l’uso completo SMC Networks, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale SMC Networks SMC6724L3 INT - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice SMC Networks SMC6724L3 INT, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per SMC Networks SMC6724L3 INT che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo SMC Networks SMC6724L3 INT - che ci dovrebbe aiutare nei primi passi durante l'uso SMC Networks SMC6724L3 INT
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del SMC Networks SMC6724L3 INT
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio SMC Networks SMC6724L3 INT in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su SMC Networks SMC6724L3 INT?

Utilizza il modulo sottostante

Se non hai risolto il problema con SMC Networks SMC6724L3 INT con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con SMC Networks SMC6724L3 INT è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)