Manuale per l’uso ADTRAN T200 H2TU-R

21 pagine 0.52 mb
Scarica

Vai alla pagina of 21

Summary
  • ADTRAN T200 H2TU-R - page 1

    61150090L1-5A Section 61150090L1-5A, Issue 1 1 Section 61150090L1-5 Issue 1, April 1999 List 1: CLEI CODE # T1MJ4U0MRA List 2: CLEI CODE # T1MJ5U0MRA List 3: CLEI CODE # T1MJ4V0MRA List 4: CLEI CODE # T1MJ5V0MRA High Capacity T200/T400 Cabinet Installation and Maintenance Figure 1. High-Capacity T200/T400 Cabinet (Pad Mount Model) 1. GENERAL This p ...

  • ADTRAN T200 H2TU-R - page 2

    2 Section 61150090L1-5A, Issue 1 61150090L1-5A • Moisture absorbing desiccant. • Spare cable hole entrance with removable seal. • Mounting template for craft planning. Cabinet Access The front and rear cabinet doors and support bracket access panels include tamper resistant security fasteners. The cabinet doors allow for a customer supplied l ...

  • ADTRAN T200 H2TU-R - page 3

    61150090L1-5A Section 61150090L1-5A, Issue 1 3 Figure 2. Cabinet Assembly, Rear View Fan Operation and Indication Two thermostatically controlled line powered cooling fans limit heat buildup. The primary fan energizes at about 110 ° F. The secondary fan energizes at about 150 ° F. Primary and secondary fan board operation is monitored by the FPU. ...

  • ADTRAN T200 H2TU-R - page 4

    4 Section 61150090L1-5A, Issue 1 61150090L1-5A 2. INSTALLATION The cabinet assembly weighs about 200 pounds. This Practice assumes that proper lifting devices are on hand for maneuvering and holding the cabinet in position until securely mounted. After unpacking the T200/T400 High Capacity Cabinet inspect it for damage. If damage is noted file a cl ...

  • ADTRAN T200 H2TU-R - page 5

    61150090L1-5A Section 61150090L1-5A, Issue 1 5 the bracket pattern. Refer to Figure 4 for pad mount access dimensions. 1. At the installation site remove all packaging material enclosing the cabinet. 2. Remove and set aside the mounting hardware kit. Verify contents per Table 2 . 3. The cabinet is bolted to two boards running across the box frame. ...

  • ADTRAN T200 H2TU-R - page 6

    6 Section 61150090L1-5A, Issue 1 61150090L1-5A 9. Hoist the cabinet to an upright position and center it over the pad. CAUTION The minimum internal bend radius for cable stubs is nine inches. 10. At this time, on the cable stub model, the cable stubs should be fed through their designated conduit or other route per craft plan. 11. Lower the cabinet ...

  • ADTRAN T200 H2TU-R - page 7

    61150090L1-5A Section 61150090L1-5A, Issue 1 7 4. Attach lifting details. Screwed into each side of the cabinet is a group of three bolts and washers. Remove these for reuse. NOTE Observe that one of the lifting details is also the mounting bracket. Ensure the mounting bracket is attached to the side of the cabinet designated to be against the pole ...

  • ADTRAN T200 H2TU-R - page 8

    8 Section 61150090L1-5A, Issue 1 61150090L1-5A 16. If the unused lifting detail is to be removed, replace the fasteners removed in step 4 ensuring the sealing washer is installed next to the cabinet. NOTE All unused threaded openings in the cabinet must have their designated fasteners inserted and tightened to ensure a proper seal. H-Frame Mount Fo ...

  • ADTRAN T200 H2TU-R - page 9

    61150090L1-5A Section 61150090L1-5A, Issue 1 9 diameter range from 0.86 to 1.26 inches. Use care to ensure correct sequence of assembly. b. Insert the O-ring evenly in the groove provided on the sealing grommet. c. Insert the sealing grommet up through the designated cable opening until the O-ring is flush with the bottom of the cabinet. d. Screw t ...

  • ADTRAN T200 H2TU-R - page 10

    1 0 Section 61150090L1-5A, Issue 1 61150090L1-5A NOTE Refer to Splice Module installation instructions for the length required inside the cabinet. Ensure sufficient sheathed cable exists at the top of the sealing grommet to install shield connectors. i. Using a wrench to hold the sealing grommet steady, use a second wrench to tighten the compressio ...

  • ADTRAN T200 H2TU-R - page 11

    61150090L1-5A Section 61150090L1-5A, Issue 1 11 III. SHRINK-WRAP After all other connections are completed, or correct wire lengths verified, complete the shrink-wrap process as follows: a. Position the shrink-wrap up against the bottom of the cabinet enclosing the entire sealing grommet assembly. b. Heat treat the shrink-wrap until properly constr ...

  • ADTRAN T200 H2TU-R - page 12

    1 2 Section 61150090L1-5A, Issue 1 61150090L1-5A Splice Module #1 Blue Binder Group Surge Arrestor Header Connection Used on Cable A only Ckt Bd Slot Connections Surge Arrestor Header Connection Orange Binder Group Splice Module #2 Used on Cable A only Table 5A. Splice Module 1 Table 5B. Splice Module 2 p i Tg n i R X X e t i h W e u l B 5 . 1 P 6 ...

  • ADTRAN T200 H2TU-R - page 13

    61150090L1-5A Section 61150090L1-5A, Issue 1 13 Table 6A. Circuit Technology Configuration Chart (Part 1) t k C # k c a P# k c a P # k c a P # k c a P# k c a P # n i P &# n i P & # n i P & # n i P &# n i P & d a e Le l b a C r e d n i Br e d n i B r e d n i B r e d n i Br e d n i B r o l o Cr o l o C r o l o C r o l o Cr o l o C ...

  • ADTRAN T200 H2TU-R - page 14

    1 4 Section 61150090L1-5A, Issue 1 61150090L1-5A Table 6B. Circuit Technology Configuration Chart (Part 2) # k c a P # n i P d n a# n i P d n a # n i P d n a # n i P d n a# n i P d n a d a e Le l b a C r e d n i Br e d n i B r e d n i B r e d n i Br e d n i B r o l o Cr o l o C r o l o C r o l o Cr o l o C r i a P # # # # # p i T e r i We r i W e r ...

  • ADTRAN T200 H2TU-R - page 15

    61150090L1-5A Section 61150090L1-5A, Issue 1 15 Figure 13. Primary & Secondary Fan Boards 3. TESTING General Each test identifies a particular malfunction. For that reason associated components used to isolate a malfunction are assumed to be functioning correctly. Certain troubleshooting requires personnel at both the Central Office to monitor ...

  • ADTRAN T200 H2TU-R - page 16

    1 6 Section 61150090L1-5A, Issue 1 61150090L1-5A 3. Disable the front door switch by centering the rod and pulling outward. The secondary fan board Door LED should go Off and the Door Alarm LED at the FPU will turn green. Fan Operation When the cabinet is initially installed without heat generating circuit packs, the primary and secondary fans will ...

  • ADTRAN T200 H2TU-R - page 17

    61150090L1-5A Section 61150090L1-5A, Issue 1 17 If the cabinet has been opened during the day allowing the heat to escape before proper troubleshooting tests could be conducted, close the cabinet doors and allow the cabinet internal temperature to restabilize. Recheck during the hottest time of the following day before the outside temperature has a ...

  • ADTRAN T200 H2TU-R - page 18

    1 8 Section 61150090L1-5A, Issue 1 61150090L1-5A Figure 15. Surge Arrestor Gas Tube Replacement 6. Disconnect the door switch JP2 connector on the fan board by carefully pulling the connector off the header. DO NOT PULL ON WIRES. 7. Take an insulated ball-clip or alligator-clip and short across the two exposed door switch JP2 connector pins at the ...

  • ADTRAN T200 H2TU-R - page 19

    61150090L1-5A Section 61150090L1-5A, Issue 1 19 4. Replace the remaining gas tubes in the same manner. Each slot has four gas tubes. 5. Untag and reinsert the associated slot power module at the CO. 6. Perform circuit tests to verify proper circuit operation. NOTE If lightning is the suspected cause of circuit pack failure, ADTRAN recommends replac ...

  • ADTRAN T200 H2TU-R - page 20

    2 0 Section 61150090L1-5A, Issue 1 61150090L1-5A Door Switch Replacement The door switch can be replaced in the field if it is damaged or becomes defective. WARNING High Voltages are present on exposed pins. Do not contact exposed surfaces. The following procedure applies to either the front or rear door switch ( Figure 16 ): 1. On the affected swi ...

  • ADTRAN T200 H2TU-R - page 21

    61150090L1-5A Section 61150090L1-5A, Issue 1 21 f l e h S p o T # t o l S# t o l S # t o l S # t o l S# t o l S e m a N r e m o t s u C. D . I t i u c r i Ce t u o R m e t s y S# m e t s y Se p y T t i u c r i C 1 2 3 4 5 6 7 8 9 0 1 1 1 2 1 f l e h S m o t t o B # t o l S# t o l S # t o l S # t o l S# t o l S e m a N r e m o t s u C. D . I t i u c ...

Fabbricante ADTRAN Categoria Network Card

I documenti che otteniamo dal fabbricante del dispositivoADTRAN T200 H2TU-R possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici ADTRAN
- manuali per l’uso T200 H2TU-R
- schede prodotto ADTRAN
- opuscoli
- o etichette energetiche ADTRAN T200 H2TU-R
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso ADTRAN T200 H2TU-R.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione ADTRAN T200 H2TU-R, manuali di manutenzione, brevi manuali o manuali utente ADTRAN T200 H2TU-R. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto ADTRAN T200 H2TU-R.

Manuali per l’uso simili

Manuale completo del dispositivo ADTRAN T200 H2TU-R, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare ADTRAN T200 H2TU-R dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti ADTRAN T200 H2TU-R.

Il manuale per l’uso completo ADTRAN, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale ADTRAN T200 H2TU-R - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice ADTRAN T200 H2TU-R, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per ADTRAN T200 H2TU-R che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo ADTRAN T200 H2TU-R - che ci dovrebbe aiutare nei primi passi durante l'uso ADTRAN T200 H2TU-R
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del ADTRAN T200 H2TU-R
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio ADTRAN T200 H2TU-R in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su ADTRAN T200 H2TU-R?

Utilizza il modulo sottostante

Se non hai risolto il problema con ADTRAN T200 H2TU-R con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con ADTRAN T200 H2TU-R è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)