  • Powerex MPD0508 - page 1

    Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. Powerex • ...

  • Powerex MPD0508 - page 2

    To help recognize this information, observe the following symbols. Danger indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Warning indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Caution indicates a potentially hazardous situation w ...

  • Powerex MPD0508 - page 3

    3 Medical Package System compressor to avoid stresses caused by changes in hot and cold conditions. 3. Piping supports should be anchored separately from the compressor to reduce noise and vibration. 4. Never use any piping smaller than the compressor connection. 5. Use flexible hose to connect the outlet of the compressor to the piping so that the ...

  • Powerex MPD0508 - page 4

    Medical Package System 4 Specifications Medical Package Duplex – Model MPD Medical Package Triplex – Model MPT Medical Package Quadplex – Model MPQ MODEL HP PHASE RPM VOLTAGE MPD0508 5(2) 3 33.4 36.2 870 208 / 230 / 460 17.4 / 16.5 / 8.2 120 64 x 65 x 76 1288 MPD0758 7 .5(2) 3 52.2 55.1 840 208 / 230 / 460 23.4 / 22 / 11 120 64 x 65 x 76 1340 ...

  • Powerex MPD0508 - page 5

    Tank Drain moisture Daily 2500 Inlet air filter Replace ●▲ (Every 2,500 hrs or less) Blower fan Clean ●●●● Fan Duct Clean ●●●● Compressor Fins Clean ● (Every 2,500 hrs or less) Bearings Replace ●●▲ Compression rings Replace ▲▲ Wrist pin bearing Regrease ▲▲ Piston set Replace ▲ V-belt Inspect, replace *Note 3 ? ...

  • Powerex MPD0508 - page 6

    Medical Package System 6 Ref. No. Description Part Number Qty. 1 Compressor Pump: 5 HP OPT050 1 7-1/2 HP OPT100 1 10 HP OPT100 1 15 HP OPT150 1 2 Corrosion Resistant Vertical Tank 120 Gal. Consult factory for number 1 200 Gal. Consult factory for number 1 240 Gal. Consult factory for number 1 3 Dew Point Monitor/Probe Refrigerated ACO500100 1 Dessi ...

  • Powerex MPD0508 - page 7

    Medical Package System 7 Ref. No. Description Part Number 1 Refrigerated Dryer: 20 CFM ACO200020 25 CFM ACO200025 35 CFM ACO300035 45 CFM ACO000045 55 CFM ACO200055 60 CFM ACO200060 70 CFM ACO200070 100 CFM ACO200100 150 CFM ACO200150 200 CFM ACO200200 2 Filter Packages: 1/2 ” -40 CFM MFP-040-342 1/2 ” -50 CFM MFP-050-342 3/4 ” -60 CFM MFP-06 ...

  • Powerex MPD0508 - page 8

    Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or prop- erty damage! Retain instructions for future reference. Powerex ? ...

  • Powerex MPD0508 - page 9

    2 Oilless Reciprocating Air Compr essor Pumps 4. Clearance must allow for safe, effec- tive inspection and maintenance. 5. If necessary, use metal shims or level- ing pads to level the compressor. Never use wood to shim the compressor. VENTILATION 1. If the oilless compressor is located in a totally enclosed room, an exhaust fan with access to outs ...

  • Powerex MPD0508 - page 10

    3 Oilless Reciprocating Air Compr essor Pumps GH Model No. HP A B C D E F (Diameter) (O.D. Flywheel) Dimensions (inches) OPS 010 1 - 1 1 / 2 6.7 3.2 11.7 16.2 7.5 4.2 .38 Ø11.2 Ax1 OPS 030 2 - 3 8.3 3.7 13.4 17.8 18.9 6.4 .43 Ø13.8 Bx1 OPT 050 5 11.4 5.3 18.3 21.9 25.9 7.9 .43 Ø16.9 Bx2 OPT 100 7 1 / 2 - 10 12.2 6.3 20.0 21.6 29.7 8.4 .55 Ø18.3 ...

  • Powerex MPD0508 - page 11

    Oilless Reciprocating Air Compr essor Pumps Maintenance Schedule Operating Hours Item Action needed 500 2500 5000 10,000 15,000 20,000 Remarks Tank Drain moisture Daily Drain tank daily Inlet Air Filter Replace  (Every 2,500 hrs or less) Blower Fan Clean  Fan Duct Clean  Compressor Fins Clean  (Every 2,500 hrs or le ...

  • Powerex MPD0508 - page 12

    5 Oilless Reciprocating Air Compr essor Pumps V alve Inspection/ Replacement (Inspect Every 5,000 Hours) INSPECT VALVE SET 1. Remove head bolts from cylinder head. Head bolts for some models are used also as cylinder bolts, which penetrates crankcase (See Figure 7). 2. Remove cylinder head and valve set. If it is difficult to remove by hand, insert ...

  • Powerex MPD0508 - page 13

    Figure 10 6 Oilless Reciprocating Air Compr essor Pumps OPS010 OPT050, OPT150 OPS030 OPT100 Cylinder Bolt T orque 156 in. lb. 295 in. lb. OPS010, OPS030, OPT050, OPT100, OPT150 Head Bolt T orque 156 in. lb. Cylinder Inspection/Replacement 1. Remove cylinder head and valve set. Pay attention not to lose semicircular (black plastic) seat inserted at ...

  • Powerex MPD0508 - page 14

    7 Oilless Reciprocating Air Compr essor Pumps 1. Remove cylinder head and cylinder. 2. Do not use tool to remove the ring. NOTE: Expanding ring too much and deforming can cause wear and leakage. (See Figure 12). Mark upper surface (not lower surface) of removed ring for easy distinction. 3. Inspect lower surface (A) and outer side surface (B) of ri ...

  • Powerex MPD0508 - page 15

    Pump No. of Piston Mark on Compressor No. Rings per Top of Model Bore Cylinders Piston Piston OPS010 65 mm 1 1 Flywheel side Fan side OPS030 65 mm 1 1 Flywheel side Fan side OPT050 LP 105 mm 1 1 Flywheel side HP 75 mm 1 2 Fan side OPT100 LP 90 mm 2 1 Flywheel side HP 75 mm 1 2 Fan side OPT150 LP105 2 1 Flywheel side HP75 1 2 Fan side 8 Oilless Reci ...

  • Powerex MPD0508 - page 16

    9 Oilless Reciprocating Air Compr essor Pumps WRIST PIN BEARING SEAL REPLACEMENT (REPLACE EVER Y 10,000 HOURS) Replacing Oil Seal 1. Insert the plastic retention sleeve which protects the needle bearing from dropping out. 2. Remove the two oil seals by using a screwdriver. 3. Clean both surfaces where oil seals are removed. 4. Push the oil seal int ...

  • Powerex MPD0508 - page 17

    10 Oilless Reciprocating Air Compr essor Pumps Inspect Connecting Rod, Wrist Pin and Crankshaft REPLACE CONNECTING ROD SET AND CRANKSHAFT AS A SET Pressing bearing into connecting rod and connecting rod set into crankshaft requires special fixtures. Without such fixtures, the squareness and paral- lelism of each part will be affected. DISASSEMBLE A ...

  • Powerex MPD0508 - page 18

    11 Oilless Reciprocating Air Compr essor Pumps Notes ...

  • Powerex MPD0508 - page 19

    12 Oilless Reciprocating Air Compr essor Pumps Figure 24 - Replacement Parts Illustration for OPS010 ...

  • Powerex MPD0508 - page 20

    13 Oilless Reciprocating Air Compr essor Pumps Ref. Part Number for model No. Description OPS010 Qty 1 Cylinder 91000560 1 6 Cylinder head 91002630 1 16 Elbow (Unloader) 06800261 1 18 Unloader cap 01052041 1 24 Spring guide set 91932560 1 27 Bolt (cylinder head) 06137835 4 33 Bolt (cylinder) 06137825 8 34 Bolt (bearing cap) 06137620 8 35 Crankcase ...

  • Powerex MPD0508 - page 21

    14 Oilless Reciprocating Air Compr essor Pumps Figure 25 - Replacement Parts Illustration for OPS030 ...

  • Powerex MPD0508 - page 22

    15 Oilless Reciprocating Air Compr essor Pumps Ref. Part Number for model No. Description OPS030 Qty 1 Cylinder 91000560 2 6 Cylinder head 91002640 2 16 Elbow (unloader) 06800261 1 17 Tee union assembly 06803261 1 20 Intake joint (1) 91345561 1 21 Intake joint (2) 91346571 1 24 Spring guide set 91932560 2 27 Bolt (cylinder head) 06137835 8 30 Flang ...

  • Powerex MPD0508 - page 23

    16 Oilless Reciprocating Air Compr essor Pumps Figure 26 - Replacement Parts Illustration for OPT050 197 197 ...

  • Powerex MPD0508 - page 24

    17 Oilless Reciprocating Air Compr essor Pumps Part Number Ref. for model No. Description OPT050 Qty 1 Cylinder (LP) 91000680 1 2 Cylinder (HP) 91947680 1 3 Liner 91177680 2 6 Cylinder Head (LP) 91002691 1 7 Cylinder Head (HP) 91002680 1 14 Elbow (Intercooler) 01415690 2 17 Tee Union Ass’y 06803261 2 18 Unloader Cap 01052451 2 20 Intake Joint 913 ...

  • Powerex MPD0508 - page 25

    Oilless Reciprocating Air Compr essor Pumps 18 Figure 27 - Replacement Parts Illustration for OPT100 and OPT150 197 197 171 172 ...

  • Powerex MPD0508 - page 26

    1 Cylinder (LP) 91000670 91000680 2 2 Cylinder (HP) 91947680 91947680 1 6 Cylinder head (LP) 91002691 91002691 2 7 Cylinder head (HP) 91002680 91002680 1 14 Elbow (Intercooler) 01415690 01415690 4 17 Tee union assembly IP010400AV IP010400AV 2 17-1 Elbow union assembly 96800261 96800261 1 18 Unloader cap 01052451 01052451 3 20 Intake joint (1) 01345 ...

  • Powerex MPD0508 - page 27

    Oilless Reciprocating Air Compr essor Pumps Powerex Limited W arranty POWEREX 3 YEAR / 10,000 HOUR EXTENDED PARTS LIMITED WARRANTY - Powerex warrants each Compressor Pump or Scroll Air-End against defects in material or workmanship from the date of purchase for a period of Three years or 10,000 hours , whichever may occur first. This warranty appli ...

Fabbricante Powerex Categoria Food Saver

I documenti che otteniamo dal fabbricante del dispositivoPowerex MPD0508 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Powerex
- manuali per l’uso MPD0508
- schede prodotto Powerex
- opuscoli
- o etichette energetiche Powerex MPD0508
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Powerex MPD0508.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Powerex MPD0508, manuali di manutenzione, brevi manuali o manuali utente Powerex MPD0508. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Powerex MPD0508.

Manuali per l’uso simili

Manuale completo del dispositivo Powerex MPD0508, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Powerex MPD0508 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Powerex MPD0508.

Il manuale per l’uso completo Powerex, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Powerex MPD0508 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Powerex MPD0508, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Powerex MPD0508 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Powerex MPD0508 - che ci dovrebbe aiutare nei primi passi durante l'uso Powerex MPD0508
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Powerex MPD0508
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Powerex MPD0508 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Powerex MPD0508?

Utilizza il modulo sottostante

Se non hai risolto il problema con Powerex MPD0508 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Powerex MPD0508 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)