    INST ALLA TION INSTRUCTIONS AND OWNER’S MANUAL UNVENTED ROOM HEA TER MODELS SR-10T -3 SR-18T -3 SR-30T -3 W ARNING: If not installed, operated and main- tained in acco rdance wit h the manu facturer’s instructions, this product could expose you to substances in fuel or fr om fuel combustion which can cause death or serious illness. This is an u ...

  • Empire Comfort Systems SR-10T-3 - page 2

    16941-5-0907 Page 2 SECTION P AGE Important Safety Information ..................................................................................... 3 Safety Information for Users of LP Gas ..................................................................... 4 Introduction ........................................................................... ...

  • Empire Comfort Systems SR-10T-3 - page 3

    16941-5-0907 Page 3 • An unvented r oom heater having an input rating of more than 6,000 Btu per hour shall not be installed in a bathroom. • An unvented room heater having an input rating of mor e than 10,000 Btu per hou r sha ll not be inst alled in a bed room or bathr oom. • Due to high temperatur es, the appliance should be located out of ...

  • Empire Comfort Systems SR-10T-3 - page 4

    16941-5-0907 Page 4 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in pr opane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor . Sometimes other odors in the are ...

  • Empire Comfort Systems SR-10T-3 - page 5

    16941-5-0907 Page 5 *Floor stand can not be used in a bedroom installation. SR-10T must be wall mounted in a bedroom installation. The bathroom or bedroom must be an unconfined space. ANSI Z223.1/NFP A54 defines an unconfined space as “a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour (4.8m 3 per kw) of the aggregate i ...

  • Empire Comfort Systems SR-10T-3 - page 6

    16941-5-0907 Page 6 W ater vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU’ s (.3KW’ s) of gas input per hour . Unvented room heaters must be used as supplemental heat (a room) rather than a primary heat source (an entire house). In most supplemental heat ...

  • Empire Comfort Systems SR-10T-3 - page 7

    16941-5-0907 Page 7 The gas line can be routed either through the floor or wall. The gas line opening should be made at this time. Location of the opening will be determined by the position of floor joists and the valve and union used for servicing. Gas Supply Check all local codes for requirements, especially for the size and type of gas supply ...

  • Empire Comfort Systems SR-10T-3 - page 8

    16941-5-0907 Page 8 When facing the front of the appliance the following minimum clearances to combustible construction must be maintained. Left side 6 inches (152mm). Right side 6 inches (152mm). Do not install in alcove or closet. Rear wall 0 inches (0mm). Ceiling 24 inches (610mm). Minimum vertical clearance from a projection above the appliance ...

  • Empire Comfort Systems SR-10T-3 - page 9

    16941-5-0907 Page 9 When facing the front of the appliance the following minimum clearances to combustible construction must be maintained. Left side 6 inches (152mm). Right side 6 inches (152mm). Do not install in alcove or closet. Rear wall 0 inches (0mm). Ceiling 36 inches (914mm). Minimum vertical clearance from a projection above the appliance ...

  • Empire Comfort Systems SR-10T-3 - page 10

    16941-5-0907 Page 10 Refer to Figures 7, 8 and 9 for measurements in order to locate (4) mounting holes on wall. Figures 7, 8 and 9 are the front views of the heaters. 1. Remove lower louver from casing assembly (2 screws). 2. Remove reflector from casing assembly (2 screws). 3. Remove upper louver from casing assembly (2 screws). (28 mm) (300 mm) ...

  • Empire Comfort Systems SR-10T-3 - page 11

    16941-5-0907 Page 1 1 4. Mount heater onto the (4) screwheads and complete tightening the screwheads to the plastic expansion anchors. Attention! Use the following steps to properly align the upper louver and the reflector with the heat shield. a. When replacing upper louver , be sure the bottom lip of upper louver goes behind the heat shield. b. ...

  • Empire Comfort Systems SR-10T-3 - page 12

    16941-5-0907 Page 12 FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result caus- ing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly . B. BEFORE LIGHTING ...

  • Empire Comfort Systems SR-10T-3 - page 13

    16941-5-0907 Page 13 SR-10T , SR-18T and SR-30T Main Burner Flame (Figure12) The main burner flame will have a red-orange glow over the surface of the ceramic plaques. A few small, hairline cracks may form over the surface of the ceramic plaques or at the edges of the ceramic plaques where they have been cemented into position on the burner assemb ...

  • Empire Comfort Systems SR-10T-3 - page 14

    16941-5-0907 Page 14 The correct flame will be blue and will extend beyond the ther - mocouple. The flame will surround the thermocouple just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet. Figure 13 Oxygen Depletion Sensor Pilot (Figur e 14) When the pilot has a large yellow tip flame, clean t ...

  • Empire Comfort Systems SR-10T-3 - page 15

    16941-5-0907 Page 15 Removing Pilot/Thermocouple From Main Burner Assembly Att ent ion: The ther moc oupl e CAN NOT be repl aced as an in divi dual item. Y ou must order a new pilot when replacing thermocouple. 1. T urn OFF gas supply to the heater . 2. T urn OFF electrical supply to the heater if optional blower is installed in heater . 3. Remove ...

  • Empire Comfort Systems SR-10T-3 - page 16

    16941-5-0907 Page 16 PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. 1 13347 CASING SIDE ASSEMBL Y - LEFT 2 SR-180 CASING BACK 3 R-2313 PIEZO IGNITOR 4 SR-008 CASING SIDE ASSEMBL Y - RIGHT 5 SR-1 13 V AL VE BRACKET 6 R-6563 GAS V AL VE -SIT 7 12438 TUBING - GAS V AL VE T O BURNER 8 12437 TUB ...

  • Empire Comfort Systems SR-10T-3 - page 17

    16941-5-0907 Page 17 INDEX P AR T NUMBER NUMBER DESCRIPTION SR-18T INDEX P AR T NUMBER NUMBER DESCRIPTION 1 13348 CASING SIDE ASSEMBL Y - LEFT 2 SR-090 CASING BACK 3 R-2313 PIEZO IGNITOR 4 SR-008 CASING SIDE ASSEMBL Y - RIGHT 5 SR-1 13 V AL VE BRACKET 6 R-6563 GAS V AL VE -SIT 7 R-2330 BURNER 8 SR-1 19 ORIFICE SHIELD 9 SR-032 PILOT BRACKET 10 R-630 ...

  • Empire Comfort Systems SR-10T-3 - page 18

    16941-5-0907 Page 18 SR-10T P AR TS VIEW ...

  • Empire Comfort Systems SR-10T-3 - page 19

    16941-5-0907 Page 19 SR-18T P AR TS VIEW ...

  • Empire Comfort Systems SR-10T-3 - page 20

    16941-5-0907 Page 20 SR-30T P AR TS VIEW ...

  • Empire Comfort Systems SR-10T-3 - page 21

    16941-5-0907 Page 21 REFLECTOR A ND LOUVERS ARE REMOVED FROM CASING ASSEMBL Y GROUND WIRE SCRE W F AN CONTROL HEA T SHIELD CORD SET HOLE IN CASING BAC K INST ALLING OPTIONAL BLOWER SRB-18T OR SRB-30T If heater is inst alled onto the wall, in order to install the optiona l blower , the heater must be removed from the wall. If heater is installed on ...

  • Empire Comfort Systems SR-10T-3 - page 22

    16941-5-0907 Page 22 Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or , in the absence of local codes, with the National Electri - cal Code, ANSI/NFP A 70, if an external electrical source is utilized . This appliance is equipped with a three-pr ong [grounding] plug for your protection against sh ...

  • Empire Comfort Systems SR-10T-3 - page 23

    16941-5-0907 Page 23 SER VICE NOTES ...

  • Empire Comfort Systems SR-10T-3 - page 24

    16941-5-0907 Page 24 Empire Comfort Systems, Inc. 918 Freeburg A ve. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 F AX: 618-233-7097 or 800-443-8648 info@empirecomfort.com www .empirecomfort.com ...

Fabbricante Empire Comfort Systems Categoria Electric Heater

I documenti che otteniamo dal fabbricante del dispositivoEmpire Comfort Systems SR-10T-3 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Empire Comfort Systems
- manuali per l’uso SR-10T-3
- schede prodotto Empire Comfort Systems
- opuscoli
- o etichette energetiche Empire Comfort Systems SR-10T-3
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Empire Comfort Systems SR-10T-3.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Empire Comfort Systems SR-10T-3, manuali di manutenzione, brevi manuali o manuali utente Empire Comfort Systems SR-10T-3. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Empire Comfort Systems SR-10T-3.

Manuale completo del dispositivo Empire Comfort Systems SR-10T-3, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Empire Comfort Systems SR-10T-3 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Empire Comfort Systems SR-10T-3.

Il manuale per l’uso completo Empire Comfort Systems, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Empire Comfort Systems SR-10T-3 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Empire Comfort Systems SR-10T-3, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Empire Comfort Systems SR-10T-3 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Empire Comfort Systems SR-10T-3 - che ci dovrebbe aiutare nei primi passi durante l'uso Empire Comfort Systems SR-10T-3
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Empire Comfort Systems SR-10T-3
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Empire Comfort Systems SR-10T-3 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Empire Comfort Systems SR-10T-3?

Utilizza il modulo sottostante

Se non hai risolto il problema con Empire Comfort Systems SR-10T-3 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Empire Comfort Systems SR-10T-3 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)