Manuale per l’uso Lincoln Electric SA-250

28 pagine 0.42 mb
Scarica

Vai alla pagina of 28

Summary
  • Lincoln Electric SA-250 - page 1

    S A-250 PERKINS Diesel Engine Driven DC Arc W elding Po wer Source OPERA TOR’S MANUAL For use with machines having Code Number 10073 or 10073CV: 10074 IM518-A October, 2000 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ...

  • Lincoln Electric SA-250 - page 2

    FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. ________________________________________________ ...

  • Lincoln Electric SA-250 - page 3

    ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistant material to protect your skin ...

  • Lincoln Electric SA-250 - page 4

    FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer ’ s recommendations. 8.c. Ground the equipment in accordance with the U.S. National Electrical ...

  • Lincoln Electric SA-250 - page 5

    iv SAFETY iv PR É CA UTIONS DE S Û RET É Pour votre propre protection lire et observer toutes les instruc- tions et les pr é cautions de s û ret é specifiques qui parraissent dans ce manuel aussi bien que les pr é cautions de s û ret é g é n é rales suivantes: S û ret é Pour Soudage A L ’ Arc 1. Protegez-vous contre la secousse é le ...

  • Lincoln Electric SA-250 - page 6

    Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. Pay par ...

  • Lincoln Electric SA-250 - page 7

    – 6 – T ABLE OF CONTENTS Page GENERAL DESCRIPTION ..................................................................................................7 DESIGN SUMMARY ............................................................................................................7 OPTIONAL FEATURES ..................................................... ...

  • Lincoln Electric SA-250 - page 8

    GENERAL DESCRIPTION The SA-250 is a heavy duty engine-driven DC arc welding power source capable of providing constant current output for stick welding or DC TIG welding. With the addition of the optional Wire Feed Module for K1283-4, the SA-250 will provide constant voltage output for running the LN-25, LN-23P or LN-7 wire feeders. The Wire Feed M ...

  • Lincoln Electric SA-250 - page 9

    OPTIONAL FEA TURES Accessory Set (K703) Includes electrode and work cables, headshield, work clamp, and electrode holder. Ether Start Kit (K793-1) for P erkins Engine When frequent starting is expected below 10 ° F (-12 ° C), remove the “ thermostart ” system and install the optional ether start kit to provide maximum cold weather starting as ...

  • Lincoln Electric SA-250 - page 10

    – 9 – Product Name Description Horsepower Operating Speeds Displacement Capacities Perkins D3.152 3 Cylinder, 4 Cycle, Water-Cooled Diesel Engine with Thermostart Glow Plug and Engine Protection Full Load: 38.2 HP @ 1725 RPM Full Load: 1725 RPM High Idle: 1800 RPM Low Idle: 1350 RPM 152 Cu. in. (2.5 ltrs) Fuel: 15 gals (57 ltrs) Oil: 7.2 qts (6 ...

  • Lincoln Electric SA-250 - page 11

    PRE-OPERA TION INST ALLA TION Safety Precautions Exhaust Spark Arrester Some federal, state or local laws may require that diesel engines be equipped with exhaust spark arresters when they are operated in certain locations where unarrested sparks may present a fire hazard. The standard mufflers included with these welders do not qualify as a spark ...

  • Lincoln Electric SA-250 - page 12

    3. Proper placement of the equipment on the under- carriage to ensure stability side to side and front to back when being moved and when standing by itself while being operated or serviced. 4. Typical conditions of use, i.e. travel speed, rough- ness of surface on which the trailer will be operat- ed, environmental conditions & likely maintenan ...

  • Lincoln Electric SA-250 - page 13

    – 12 – Battery Charging The SA-250 is equipped with a wet charged battery. The charging current is automatically regulated when the battery is low (after starting the engine) to a trickle current when the battery is fully charged. When replacing, jumping or otherwise connecting the battery to the battery cables, the proper polarity must be obse ...

  • Lincoln Electric SA-250 - page 14

    ENGINE OPERA TION Operate the welder with the doors closed. Leaving the doors open changes the designed air flow and can cause overheating. Starting the Perkins D3.152 Engine a) Turn the idler control to “ HIGH ” . b) Turn the ignition control to “ ON ” . c) Push in the “ RESET ” button. d) Press the “ START ” button. Release button ...

  • Lincoln Electric SA-250 - page 15

    When a forceful “ digging ” arc is required, usually for vertical and overhead welding, use a higher “ Current Range Selector ” setting and lower open circuit volt- age. For example: to obtain 175 amps and a forceful arc, set the “ Current Range Selector ” to the 240-160 position and the “ Fine Current Adjustment ” setting to get 17 ...

  • Lincoln Electric SA-250 - page 16

    MAINTENANCE General Instructions for Diesel Engine W elders 1. Blow out the welder and controls with an air hose at least once every two months. In particularly dirty locations, this cleaning may be necessary once a week. Use low pressure air to avoid driving dirt into the insulation. 2. “ Current Range Selector ” contacts should not be greased ...

  • Lincoln Electric SA-250 - page 17

    3. Change the crankcase oil at regular intervals using the proper grade of oil as recommended in the engine operating manual. 4. Change the oil filter in accordance with the instruc- tions in the engine operator ’ s manual. When the filter is changed, add a quart of oil to the crankcase to replace the oil held in the filter during operation. 5. I ...

  • Lincoln Electric SA-250 - page 18

    Idler Maintenance Before doing electrical work on the idler printed circuit board, disconnect the battery. ------------------------------------------------------------------------ 1. The solenoid plunger must work freely because binding can cause engine surging. If surging occurs, be sure the plunger is properly lined up with the throttle lever. Du ...

  • Lincoln Electric SA-250 - page 19

    – 18 – TROUBLE A. Machine fails to hold the “ heat ” consistently. B. Welder starts but fails to gener- ate current. C. Welding arc is loud and spat- ters excessively. CA USE 1. Rough or dirty commutator. 2. Brushes may be worn down to limit. 3. Field circuit may have variable resistance connection or inter- mittent open circuit due to loos ...

  • Lincoln Electric SA-250 - page 20

    – 19 – TROUBLE D. Welding current too great or too small compared to indica- tion on the dial. E. Arc continuously pops out. CA USE 1. Exciter output low causing low output compared to dial indica- tion. 2. Operating speed too low or high. 1. “ Current Range Selector ” switch may be set at an intermediate position. W H A TT OD O 1. Check ex ...

  • Lincoln Electric SA-250 - page 21

    – 20 – ELECTRONIC IDLER TROUBLESHOO TING GUIDE Engine Will Not Return to Idle in Approximately 15 Seconds Set Idler Control Switch to the Auto Position Check to see Whether Oil Pressure Light is On and Alternator is Charging Light OFF Light ON If Oil Light is O.K., Replace Check Continuity of Idler Oil Pressure Switch Control Switch Continuity ...

  • Lincoln Electric SA-250 - page 22

    – 21 – CONTROL PANEL COMPONENTS LEAD COLOR CODE B-BLACK G-GREEN N-BROWN B R + - + - Y R W B B U U SLIP RINGS TO IRON R N A 54 3 2 1 ALTERNATOR AUXILIARY POWER WINDINGS CURRENT TRANSFORMER CB3 CB1 115 VOLT RECEPTACLE 230 VOLT RECEPTACLE Y NEGATIVE SELECTOR SWITCH WELDER LEAD BLOCK AC AC CR2 REED RELAY 42 602A G U CB2 CB4 FUSE 15A. 1 2 3 4 5 6 7 ...

  • Lincoln Electric SA-250 - page 23

    – 22 – 16.53 22.14 22.00 27.12 .88 M8869-24 7-28-95E 24.50 8.12 3.00 31.75 52.94 32.82 43.13 28.00 20.91 6.00 65.25 53.75 61.00 35.10 67.00 * = .81 DIA HOLES = .69 DIA HOLES * * CENTER OF GRAVITY WITH OIL AND WATER IN ENGINE, BUT NO FUEL. 45.07 * 48.50 DIMENSION PRINT ...

  • Lincoln Electric SA-250 - page 24

    NO TES ...

  • Lincoln Electric SA-250 - page 25

    Now A vailable...12th Edition The Procedure Handbook of Ar c W elding With over 500,000 copies of previous editions published since 1933, the Procedure Handbook is considered by many to be the “ Bible ” of the arc welding industry. This printing will go fast so don ’ t delay. Place your order now using the coupon below. The hardbound book con ...

  • Lincoln Electric SA-250 - page 26

    W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES. SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL F ABRICANTE P ARA ...

  • Lincoln Electric SA-250 - page 27

    W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRU ÇÕ ES DO F ABRICANTE P ARA ESTE EQUIP AMENTO E AS P ARTES DE USO, E SIGA AS PR Á TICAS DE SEGURAN Ç A DO EMPREGADOR. ● Keep your head out of fumes. ● Use ventilation or exhaust to remove ...

  • Lincoln Electric SA-250 - page 28

    • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products • ...

Fabbricante Lincoln Electric Categoria Welder

I documenti che otteniamo dal fabbricante del dispositivoLincoln Electric SA-250 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Lincoln Electric
- manuali per l’uso SA-250
- schede prodotto Lincoln Electric
- opuscoli
- o etichette energetiche Lincoln Electric SA-250
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Lincoln Electric SA-250.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Lincoln Electric SA-250, manuali di manutenzione, brevi manuali o manuali utente Lincoln Electric SA-250. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Lincoln Electric SA-250.

Manuali per l’uso simili

Manuale completo del dispositivo Lincoln Electric SA-250, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Lincoln Electric SA-250 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Lincoln Electric SA-250.

Il manuale per l’uso completo Lincoln Electric, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Lincoln Electric SA-250 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Lincoln Electric SA-250, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Lincoln Electric SA-250 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Lincoln Electric SA-250 - che ci dovrebbe aiutare nei primi passi durante l'uso Lincoln Electric SA-250
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Lincoln Electric SA-250
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Lincoln Electric SA-250 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Lincoln Electric SA-250?

Utilizza il modulo sottostante

Se non hai risolto il problema con Lincoln Electric SA-250 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Lincoln Electric SA-250 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine