    1 KLS-20G, KLS-40G and KLS-60G GAS FIRED TRI-LEG STATIONARY KETTLE INSTALLATION – OPERATION – MAINTENANCE BLODGETT OVEN COMPANY www.blodgett.com 44 Lakeside Avenue, Burlington, Vermont 05 401 USA Telephone (800) 33 1-5842, (802) 860 -3700 Fax: (802) 864-0183 S00064 Rev A (5/04) ...

  • Blodgett KLS-40G, KLS-60G - page 2

    2 IMPORTANT NOTES FOR INSTALLATION AND OPERATION It is recommended that this manual be read thoroughly and that all instructions be followed carefully. This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. FOR YOUR SAFETY: Do ...

  • Blodgett KLS-40G, KLS-60G - page 3

    3 TABLE OF CONTENTS DESCRIPTION PAGE Important Notes for Installation and Operation .................................................................. 2 1.0 Service Connections ................................................................................................... 4 2.0 Installation ...................................................... ...

  • Blodgett KLS-40G, KLS-60G - page 4

    4 1.0 SERVICE CONNECTIONS KLS-20G -T otal 100,000 BTU. One 1" male connection (for location, see drawing below .) Natural Propane Required operating pressure: Natural Gas 4" W . C.; Propane Gas 10" W .C - T otal 100,000 B TU. One 1" male connection. (for location, see drawing below .) Natural Propane Required operating pressure: ...

  • Blodgett KLS-40G, KLS-60G - page 5

    5 2.0 INSTALLATION INSTALLATION CODES AND ST ANDARDS Installation must conform with local codes, or in the absence of local co des, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 , or the Natural Gas and Propane Installation Code, CSA B149.1 , as applicable. 1. The appliance and its individual shut off valve must be disconnected from the gas ...

  • Blodgett KLS-40G, KLS-60G - page 6

    6 2.0 INSTALLATION (Continued) TO INSTALL 1. Uncrate carefully. Report any hidden freight damage to the freight company immediately. 2. Set the unit in place. Be certain to maintain minimum clearances as stated above. 3. To level the unit use a spirit level in all directions on the top of the kett le (lid up). A. Units with legs - adjust the bottom ...

  • Blodgett KLS-40G, KLS-60G - page 7

    7 2.0 INSTALLATION (Continued) Purge the supply line to clean out any dust, dirt, or other foreign matter before connecting the line to the unit. It is recommended that an individual manual shut off valve be installed in the gas supply line to the unit. Use pipe joint compound which is suitab le for use with LP gas on all threaded connections. Test ...

  • Blodgett KLS-40G, KLS-60G - page 8

    8 2.0 INSTALLATION (Continued) WARNING: For an appliance equippe d with casters, the installation shall be made with a connector th at complies with the standard for connectors for moveable gas appliances, ANSI Z21.69-CSA 6.16 and a quick-disconnect device that complies with the standard for quick-disconnect devices for u se with gas fuel, ANSI Z21 ...

  • Blodgett KLS-40G, KLS-60G - page 9

    9 2.0 INSTALLATION (Continued) WARNING: ELECTRICAL GROUNDING INSTRUCTIONS This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-pr ong receptacle. Do not cut or remove the grounding prong from this plug. (120V units only). 1. 208/240 VAC ...

  • Blodgett KLS-40G, KLS-60G - page 10

    10 3.0 PERFORMANCE CHECK The following items should be checked before or within the first 30 days of operation by a qualified service technician. 1.0 Verify correct gas type. 2.0 Verify correct voltage, cycle and phase. 3.0 Gas pressure. 4.0 Internal gas connections. 5.0 Internal electrical connections. 6.0 Pilots - adjustment and ignition. 7.0 Bur ...

  • Blodgett KLS-40G, KLS-60G - page 11

    11 4.0 OPERATION WARNING: In the event of main bur ner ignition fail ure, a 5 minute purge period must be observed pr ior to re-establishing ignition source. WARNING: In the event you smell g as, shut down equipment at the main shut off valve and contact the local gas company or gas supplier for service. CAUTION: If you smell gas during the lightin ...

  • Blodgett KLS-40G, KLS-60G - page 12

    12 in the gas line) may require the unit to be turned off and immediately back on numerous times after each lockout period until the air is purged from the gas line. B. SHUTDOWN STANDBY 1. Place power on switch and thermostat to “OFF” position. COMPLETE 1. Place power on switch and thermostat to “OFF” position. 2. Turn dial on combination c ...

  • Blodgett KLS-40G, KLS-60G - page 13

    13 4.0 OPERATION (Continued) SPARK IGNITER FAILURE: In the event the spark igniter module fails the unit may still be operated by carefully following these instructions. 1. Turn thermostat to OFF position; completely counterclockwise. 2. Turn power switch to OFF position. 3. WAIT A MINIMUM OF 5 MINUTES BEF ORE PROCEEDING. 4. Turn dial on combinatio ...

  • Blodgett KLS-40G, KLS-60G - page 14

    14 4.0 OPERATION (Continued) FRONT PANEL CONTROLS: 1. Power Switch This switch turns the main power to the unit on and off. It must be turned on to heat the kettle. It should be turned off when the kettle will not be in use for long periods. 2. (Red) Cooking Light This light is on whenever the main burner gas is on. On units with standing pilots th ...

  • Blodgett KLS-40G, KLS-60G - page 15

    15 4.0 OPERATION (Continued) DAILY OPERATION Daily operation should consist of turning on the power switch and setting the thermostat f or the desired temperature. It is recommended the kettle be preheated prior to use. Milk or egg based products shou ld be placed in the kettle before heating, however, to prevent sticking. The kettle is preheated w ...

  • Blodgett KLS-40G, KLS-60G - page 16

    16 END USER TIPS: (Continued) Bring milk and egg products slowly up to temper ature in a cold kettle to prevent product adhering to the sides. When planning actual cooking capacity, allow room at top for stirring without sp illing. When preparing puddings from a mix, place the powder in a cold kettle, add a small amount of the liquid, and stir to f ...

  • Blodgett KLS-40G, KLS-60G - page 17

    17 5.0 MAINTENANCE Contact the factory, the factory representative or a local service company to perform maintenance and repairs. WARNING: Disconnect the power supply to the appliance before cleaning or servicing. Daily: 1. Wash exposed cleanable areas. Monthly: 1. Clean around burner air mixers, louvered panels and pilots if grease or lint have ac ...

  • Blodgett KLS-40G, KLS-60G - page 18

    18 5.0 MAINTENANCE (Continued) CLEANING INSTRUCTIONS WARNING: Disconnect the power supply to the appliance before cleaning or servicing. WARNING: Never spray water into electric controls or components! CAUTION: The equipment and its parts are hot. Use care when operating, cleaning and servicing. CAUTION: Do not use cleaning agents that are corrosiv ...

  • Blodgett KLS-40G, KLS-60G - page 19

    19 5.0 MAINTENANCE (Continued) CLEANING INSTRUCTIONS (Continued) DRAW-OFF VALVE CLEANI NG 1. If equipped with a tangent draw-off valve, turn the large hex nut on the draw-off valve counterclockwise until it is completely dis engaged from the threads. Grasp the valve knob and slowly pull out the valve stem and disk. Do not allow the disk to come in ...

  • Blodgett KLS-40G, KLS-60G - page 20

    20 5.0 MAINTENANCE (Continued) CLEANING INSTRUCTIONS (Continued) WHAT TO DO IF SURFAC E RUST APPEARS Metal utensils should never be used as they will scratch the surface of the equipment and rust may begin to form. To remove surface accumulation of rust from the inadvertent use of such utensils, the following procedure may be used. CAUTION: Imprope ...

  • Blodgett KLS-40G, KLS-60G - page 21

    21 5.0 MAINTENANCE (Continued) CLEANING INSTRUCTIONS (Continued) STAINLESS STEEL (Continued) Soil and burn deposits which do not respond to the above procedure can usually be removed by rubbing the surface with SCOTCH-BRITE™ scouring pads or STAINLESS scouring pads. DO NOT USE ORDINARY STEEL WOOL as any particles left on the surface will rust and ...

  • Blodgett KLS-40G, KLS-60G - page 22

    22 6.0 SERVICE WARNING: Disconnect unit from power supply before cleaning or servicing appliance. GENERAL When any difficulty arises always check that the unit has been connected to the gas supp ly type and voltage for which it was supplied. This can be done by examining the serial plate on the lower right side of the unit. It will list the gas typ ...

  • Blodgett KLS-40G, KLS-60G - page 23

    23 6.0 SERVICE (Continued) The front burner shield should be removed to see the pilot. The pilot should be adjusted as follows: Adjust the pilot burner flame The pilot flame should envelop 3/8 to ½ inch [10 to 13 mm] of the igniter-sensor tip. Refer to Figure 2. To adjust the pilot flame: 1. Remove the pilot adjustment cover screw. Refer to Figure ...

  • Blodgett KLS-40G, KLS-60G - page 24

    24 6.0 SERVICE (Continued) ADJUSTMENTS To check the manifold pressure a pressure gauge (manometer) must be connected to the 1/8" NPT pressure tap on the gas manifold. With the gas off, connect your pressure indicating instrument to the manifold with a fitting appropriate for your instrument. 1. Turn the unit on; with main burners on, read the ...

  • Blodgett KLS-40G, KLS-60G - page 25

    25 6.0 SERVICE (Continued) PRESSURE SWITCH (Continued) 1. Pressure relief valve opening, especially on preheat from a cold start to 275 degrees Fahrenheit (135 E C) (pressure switch set too high). 2. Burners are being shut down by pressure switch, not the thermostat. (Pressure switch set too low.) The pressure switch is preset for proper operation ...

  • Blodgett KLS-40G, KLS-60G - page 26

    26 6.0 SERVICE (Continued) ADDING WATER It may be necessary to replenish water in the jacket when the low water indicator comes on. Do so as follows: S Unit should be completely cold and off. S For reference, the total amount of distilled water contained in each unit, and amount to be added in a low water condition is listed below: Model Total Amou ...

  • Blodgett KLS-40G, KLS-60G - page 27

    27 with a continuity tester. If the fuse is good, check the main power circuit breaker, which should be external to the kettle. 6.0 CONVERTING BETWEEN NATU RAL AND PROPANE GAS WARNING: Fire or explosion hazard can cause property damage, severe injury, or death. 1. Do not attempt to use a gas control set for natural gas on propane gas or gas control ...

  • Blodgett KLS-40G, KLS-60G - page 28

    28 6.0 SERVICE (Continued) CONVERTING BETWEEN NATURAL AND PROPANE GA S (Continued) Figure 1 Top view of gas control. Figure 2 Installation of conversion kit in regulated gas control. ...

  • Blodgett KLS-40G, KLS-60G - page 29

    29 TROUBLESHOOTING PROBLEM LOOK FOR Unit will not come on - Power switch is off. - Unit not plugged in. - Main power supply off. - Bad electronic module. - Bad low water control. - Bad spark igniter. - Bad intermittent pilot burner. - Fuse in unit blown. Unit will turn on electrically but will not heat - Lockout has occurred. - Thermostat not on. - ...

  • Blodgett KLS-40G, KLS-60G - page 30

    30 TROUBLESHOOTING: PROBLEM LOOK FOR Excessive flame rollout on ignition, carboning - Natural gas unit on propane. - Excessive gas pressure. - Incorrect orifice size. - Faulty regulator in gas control. Unit slow to preheat and slow to recover - Propane gas on natural. - Low gas pressure. - Incorrect orifice sizes. - Loss of vacuum. - Faulty regulat ...

  • Blodgett KLS-40G, KLS-60G - page 31

    31 APPENDIX ‘A’ MATERIAL SAFETY DATA SHEET PREPARATION INFORMATION: Prepared for use in Canada by: E H & S Product Regulatory Management Department DOW CHEMICAL CANADA INC. P.O. Box 1012 Sarnia, Ontario, N7T 7K7 (800) 331-6451 1. CHEMICAL PRODUCT AND COMPAN Y IDENTIFICATION IN CASE OF EMERGENCY: Fort Saskatchewan, Alberta: (780) 998-8282 Sa ...

  • Blodgett KLS-40G, KLS-60G - page 32

    32 S HAZARDS IDENTIFICATION EMERGENCY OVERVIEW POTENTIAL HEALTH EFFECTS (See Section 11 for toxicological data.) EYE: May cause slight transient (temporary) eye i rritation. Corneal injury is unlikely. Mists may cause eye irritation. SKIN CONTACT: Prolonged contact is essentially nonirritating to skin. A single prolonged exposure is not likely to r ...

  • Blodgett KLS-40G, KLS-60G - page 33

    33 4. FIRST AID EYES: Flush eyes with plenty of water. SKIN: Wash off in flowing water or shower. INGESTION: No adverse effects anticipat ed by this route of exposure incidental to proper industrial handling. INHALATION: Remove to fresh air if effects occur. Consult a physician. NOTE TO PHYSICIAN: No specific antidote. Supportive care. Treatment ba ...

  • Blodgett KLS-40G, KLS-60G - page 34

    34 possibly resulting in spontaneous combustion. Container may rupture from gas generation in a fire situation. EXTINGUISHING MEDIA : Water fog or fine spray, carbon dioxide, dry chemical, foam. Alcohol resistant foams (ATC type) are preferred if available. General purpose synthetic foams (including AFFF) or protein foams may function, but much les ...

  • Blodgett KLS-40G, KLS-60G - page 35

    35 S EXPOSURE CONTROLS/PERSONAL PROTECTION ENGINEERING CONTROLS: Provide general and/or local exhaust ventilation to control airborne levels below the exposure guidelines. PERSON AL PROTECTIVE EQUIPM ENT EYE/FACE PROTECTION: Use safety glasses. Safety glasses should be sufficient for most operations; however, for misty operations wear chemical gogg ...

  • Blodgett KLS-40G, KLS-60G - page 36

    36 HAZARDOUS DECOMPOSITION PRODUCTS: Hazardous decomposition products depend upon temperature, air supply and the presence of other materials. HAZARDOUS POLYMERIZATION: Will not occur. 11. TOXICOLOGICAL INFORMATION (See Section 3 for Potential Health Effects. For detailed toxicological data, write or call the address or non-emergency number shown i ...

  • Blodgett KLS-40G, KLS-60G - page 37

    37 local laws and regulations. Regulations may vary in different locations. Waste characterizations and compliance with applicable laws are the re sponsibility solely of the waste generator. THE DOW CHEMICAL COMPANY HAS NO CONTROL OVER THE MANAGEMENT PRACTICES OR MANUFACT URING PROCESSES OF PARTIES HANDLI NG OR USING THIS MATERIAL. THE INFORMATION ...

  • Blodgett KLS-40G, KLS-60G - page 38

    38 U.S. REGULATIONS SARA 313 INFORMATION: To the best of our knowledge, this product contains no chemical subject to SARA Title III Section 313 supplier notification requirements. SARA HAZARD CATEGORY: This product has been reviewed according to the EPA “Hazard Categories” promulgated under Sections 311 and 312 of the Superfund Amendment and Re ...

  • Blodgett KLS-40G, KLS-60G - page 39

    39 CANADIAN REGULATIONS WHMIS INFORMATION: The Canadian Workplace Hazardous Materials Information System (WHMIS) Classification for this product is: This product is not a “Controlled Product” under WHMIS. CANADIAN ENVIRONMENTAL P ROTECTION ACT (CEPA) This product contains one or more substances which are not listed on the Canadian Domestic Subs ...

Fabbricante Blodgett Categoria Hot Beverage Maker

I documenti che otteniamo dal fabbricante del dispositivoBlodgett KLS-40G, KLS-60G possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Blodgett
- manuali per l’uso KLS-40G, KLS-60G
- schede prodotto Blodgett
- opuscoli
- o etichette energetiche Blodgett KLS-40G, KLS-60G
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Blodgett KLS-40G, KLS-60G.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Blodgett KLS-40G, KLS-60G, manuali di manutenzione, brevi manuali o manuali utente Blodgett KLS-40G, KLS-60G. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Blodgett KLS-40G, KLS-60G.

Manuali per l’uso simili

Manuale completo del dispositivo Blodgett KLS-40G, KLS-60G, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Blodgett KLS-40G, KLS-60G dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Blodgett KLS-40G, KLS-60G.

Il manuale per l’uso completo Blodgett, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Blodgett KLS-40G, KLS-60G - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Blodgett KLS-40G, KLS-60G, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Blodgett KLS-40G, KLS-60G che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Blodgett KLS-40G, KLS-60G - che ci dovrebbe aiutare nei primi passi durante l'uso Blodgett KLS-40G, KLS-60G
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Blodgett KLS-40G, KLS-60G
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Blodgett KLS-40G, KLS-60G in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Blodgett KLS-40G, KLS-60G?

Utilizza il modulo sottostante

Se non hai risolto il problema con Blodgett KLS-40G, KLS-60G con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Blodgett KLS-40G, KLS-60G è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)