Manuale per l’uso Friedrich 2007

36 pagine 1.43 mb
Scarica

Vai alla pagina of 36

Summary
  • Friedrich 2007 - page 1

    Ser vice Manual Room Air Conditioners RAC-Svc-07 (4-07) 2007 M o n e y F a n Timer Operation S e t H r . S to p S ta r t Temperatur e F a n C o o l O n /O ff Power C o o le r O n ly S p e e d S a v e r ® W a r m e r ...

  • Friedrich 2007 - page 2

    2 T ABLE OF C ONTEN TS Introducti on / T y pical Unit C omponents ....................................................................................................................................... 3 Warranty ...................................................................................................................... .................. ...

  • Friedrich 2007 - page 3

    3 INT R ODU CT ION Th is se r vi ce m a n u a l i s d e si g n e d t o b e u se d i n co n j u n c ti o n w i th t h e i n s ta l l a t i o n m an u a l s pr o vi d ed w i t h ea ch a ir co n d i ti o n i n g syst em c om po ne nt . This ser vic e manual was wr it ten to assist t he professional R A C serv ice tec hnician to quick ly and ac curatel ...

  • Friedrich 2007 - page 4

    4 Friedrich Air Conditioning Company P.O. Box 1540 San Antonio, TX 78295 210.357.4400 www.fri edri ch.c om ROOM AIR CONDITIONERS LIMITED WARRANTY FIRST YEAR A NY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRICH will repair the product at no ch ...

  • Friedrich 2007 - page 5

    5 R OU TINE MAIN TENAN C E NOT E : Un its are to be inspect ed and ser viced b y quali fi ed ser vice personnel only . Inspect the indoor blower housing, evap orator blade , condenser fan blade, and c o ndenser shroud perio dically (yearly or bi-yearly) and clean of all debris (lint, dir t, mold, fungus, etc. ) Clean t he blower housing area and b ...

  • Friedrich 2007 - page 6

    6 UNIT IDENTIFIC A TION Model N umber Code S S 08 L 1 0 A Serial Number Decade Manufactured L=0 C=3 F=6 J=9 A=1 D=4 G=7 B=2 E=5 H=8 Y ear Manufactured A=1 D=4 G=7 K=0 B=2 E=5 H=8 C=3 F=6 J=9 Month Manufactured A=Jan D=Apr G=Jul K=Oct B=Feb E=May H=Aug L=Nov C=Mar F=Jun J=Sept M=Dec L C G R 00001 Production Run Number Product Line R = RAC P = PT AC ...

  • Friedrich 2007 - page 7

    7 PER F O R M A N CE DA T A PERFORMANCE DA T A* Cooling EV AP . AIR TEMP . DEG. F CONDENSER TEMPERA TURE DEG. F Discharge Te m p Suction Te m p Super Heat Sub- Cooling OPERA TING PRESSURES ELECTRICAL RA TINGS R-22 REF . V oltage BREAKER FUSE Discharge Air T emp. Drop F . Suction Discharge Amps Cool Amps Heat Locked Rotor Amps Charge in OZ. 60 Hertz ...

  • Friedrich 2007 - page 8

    8 Wire Size Use O NL Y wir ing size recommended for single outlet branch circuit. F use/Circuit Use ONL Y ty pe and size fuse or HACR Bre ak er circuit breaker indicated on unit ’ s rating plate . Proper current protection to the unit is the responsibilit y of the ow ner . G r o u n d i n g U n i t M U S T b e g r o u n d e d f r o m b r a n c h ...

  • Friedrich 2007 - page 9

    9 MEC HANIC AL C OMPONEN TS Bellows condensate valv e T e m p e r a t u r e- s e n s i t i v e v a l v e that opens up to drain of f c ondensate water when the out side temperature falls below 40°F and c loses w hen the out side temperature reaches 58 °F . Ve n t d o o r A l l o w s i n t r o d u c t i o n o f f r e s h a i r i n t o t h e r o o ...

  • Friedrich 2007 - page 10

    10 ELE CTR ONIC CONTR OLS IMPORT ANT : Error C odes are c leared from t he log by e xiting f rom Error Co de Mode. T o exit on X Q models, pres s Timer On /Of f button. T o exit QME models, pres s A /C Star t and On /O f f but tons. Or unplug unit to exit Err or Co de Mo de. Plug unit in af ter 5 seconds to resume nor mal operation of unit. TESTING ...

  • Friedrich 2007 - page 11

    11 IMPORT ANT AN Y SE A LED S Y S TEM REP A IRS TO COOL - ON L Y MOD ELS REQUIRE THE I NST ALL A TI ON OF A L I Q U I D L I N E D R I E R . A L S O , A N Y S E A L E D S Y S T E M R E P A I R S T O H E AT P U M P M O D E L S R E Q U I R E T H E INST A LL A TIO N OF A SUCTIO N LINE D RIER . the liquid refrigerant leaves the metering device entering ...

  • Friedrich 2007 - page 12

    12 EQUIP MENT RE QUIRED 1. Vo l t m e t e r 2. Ammeter 3. Ohmmeter 4. E. P . A . A pp rove d Ref r i ger ant Rec ove r y Sy ste m. 5. V acuum Pump ( capable of 20 0 mic rons or less vacuum. ) 6. Acet ylene Welder 7 . Electronic Halogen Leak Detector (G.E. T y pe H - 6 or equiva lent. ) 8. Ac curate refrigerant charge measur ing device such as: a. B ...

  • Friedrich 2007 - page 13

    13 NOTE : I n o r d e r to ac c e s s t h e s e a l e d s y st e m i t w i l l b e n e c e s s ar y t o i ns t a l l S c h r a d e r t y p e fi tt ings to the proces s tubes on the discharge and suct ion of the c ompres sor . Proper refr igerant recover y proc edure s need to be adhered to as outlined in EP A R egulations. THIS SHO ULD O NL Y B E ...

  • Friedrich 2007 - page 14

    14 A n u n d e r c h a r g e d s y s t e m w i l l r e s u l t i n p o o r p e r f o r m a n c e ( l o w pressures, etc. ) in both the heating and c ooling cycle. Whenever you servic e a unit wit h an under char ge o f refrigerant, always suspect a leak. The leak must be repaired before charging the unit. T o check for an undercharged sy stem, turn ...

  • Friedrich 2007 - page 15

    15 A quick check for eit her condit ion begins at the evaporat or . With a par tial restric tion, there may be gurgling sounds at the metering device entrance to the e vaporator . The e vaporator in a par tial rest ric tion c ould be par t ially frosted or have an ice ball close to the entranc e of the metering device. Frost ma y continue on t he s ...

  • Friedrich 2007 - page 16

    16 NORMAL F UNC TION OF V AL VE VA LV E OPERA TIN G COND ITI ON DISCHARGE TUBE from Com presso r SUCT IO N TU BE to Compr essor Tu b e t o I N S I D E COIL Tu b e t o O U T S I D E COIL LEFT Pilot Capillary T ube RIGHT Pilot Capillary T ube NO TES : * TEM PER A TURE O F V AL V E BODY ** WA RM ER TH AN VAL VE BO DY 1 2 3 4 5 6 POSSIBL E C A U SE S C ...

  • Friedrich 2007 - page 17

    17 COOL IN G ONL Y R OOM AIR C ONDITIONER S : TROUB L E S HOO TIN G TIP S Problem Possible Cause Action Compressor does not run Low voltage Check voltage at compressor . 1 15V & 230V units will operate at 10% voltage variance T -stat not set cold enough or inoperative Set t-stat to coldest position. T est t-stat & replace if inoperative Com ...

  • Friedrich 2007 - page 18

    18 Problem Possible Cause Action Unit does not run Fuse blown or circuit tripped Replace fuse, reset breaker . If repeats, check fuse or breaker size. Check for shorts in unit wiring & components Power cord not plugged in Plug it in System switch in "OFF" position Set switch correctly Inoperative system switch T est for continuity in ...

  • Friedrich 2007 - page 19

    19 Problem Possible Cause Action Compressor runs for short periods only . Cycles on overload Overload inoperative. Opens too soon Check operation of unit. Replace overload if system operation is satisfactory Compressor restarted before system pressures equalized Allow a minimum of 2 minutes to allow pressures to equalize before attempting to restar ...

  • Friedrich 2007 - page 20

    20 Problem Possible Cause Action W ater "spitting" into room Sublimation: When unconditioned saturated, outside air mixes with conditioned air , condensation forms on the cooler surfaces Ensure that foam gaskets are installed in between window panes & in between the unit & the sleeve. Also, ensure that fresh air/exhaust vents (on ...

  • Friedrich 2007 - page 21

    21 Problem Possible Cause Action Room temperature uneven (Heating cycle) Heat anticipator (resistor) shorted (on applicable models) Disconnect power to unit. Remove resistor from t-stat bulb block. Plus in unit & allow to operate. Feel resistor for heat. If not heat, replace resistor Wide differential - partial loss of t-stat bulb charge Replac ...

  • Friedrich 2007 - page 22

    22 Problem Possible Cause Action Unit cools when heat is called for Incorrect wiring Refer to applicable wiring diagram Defective solenoid coil Check for continuity of coil Reversing valve fails to shift Block condenser coil & switch unit to cooling. Allow pressure to build up in system, then switch to heating. If valve fails to shift, replace ...

  • Friedrich 2007 - page 23

    23 ELE CT RIC AL TR OUBL ES HOO TING C HART — HEA T PUMP NO Is Line V oltage Present at the Solenoid NO YES YES TR OUBL E SHOO TING C HART — HEA TING Noncond en sab les ( air ) Ove rcha rged Low Air fl ow Acros s Indoor Coil Outdo or Am bient T o o High For Operat ion In H eating High Head P ressure REFRIGER ANT S YST EM DIA GNOSIS – HEA TIN ...

  • Friedrich 2007 - page 24

    24 MODELS XQ 0 5 L 10 - A , B; XQ 0 6 L 10 - A , B ,C, D; XQ 0 8 L 10 - A , B; XQ 10 L 10 - A , B; XQ 12 L 10 - A , B ...

  • Friedrich 2007 - page 25

    25 MODELS K S 1 0L 1 0-A, R S 1 0L 1 0-A, K S 1 2L 1 0-A, K S 1 2L 3 0-A, K S 1 5L 1 0-A, R S 1 5L 1 0-A, R S 1 6L3 0-A, RM 1 8L30 -A , KM1 8L30- A , KM21 L30- A , RM24L30 - A , KM24L30- A ...

  • Friedrich 2007 - page 26

    26 MODELS SS08L 1 0- A /B, SS 1 0L 1 0 - A /B, SS 1 2L 1 0- A /B ; SS 1 2L30 - A /B, SS 1 4L 1 0- A /B, S S 1 6L 30-A/B , S M 1 8 L3 0-A/B , S M 2 1 L3 0-A/B , S M2 4L 3 0-A/B ...

  • Friedrich 2007 - page 27

    27 MODEL SL36L3 0 - A ...

  • Friedrich 2007 - page 28

    28 MODEL SL28 L30 - A ...

  • Friedrich 2007 - page 29

    29 MODELS SL36 L30 - B ...

  • Friedrich 2007 - page 30

    30 MODEL EQ 08 L 1 1- A ...

  • Friedrich 2007 - page 31

    31 MODELS E S 1 2L 3 3-A, E S 1 6 L3 3-A, E M 1 8 L 34-A, E M 24 L 3 5-A ...

  • Friedrich 2007 - page 32

    32 MODEL EL36L35 -A ...

  • Friedrich 2007 - page 33

    33 MODEL YS 0 9 L 10 - A , YS 0 9 L 10 - B ...

  • Friedrich 2007 - page 34

    34 MODELS Y S 1 3L33 - A , YM 1 8L34 - A ...

  • Friedrich 2007 - page 35

    35 MODELS YL24L35 - A ...

  • Friedrich 2007 - page 36

    RAC-Svc-07 (4-07) F riedrich Air Condi tioning Co. Post Of f ice Box 15 4 0 • San A nto nio , T exa s 782 95 - 1 5 4 0 420 0 N. Pa n Am Expr e ss way • San A ntonio, T exa s 7821 8 -521 2 (210) 357 - 44 0 0 • F A X (210) 357 - 4 4 8 0 w w w. friedrich .com Printe d in th e U .S.A . ...

Fabbricante Friedrich Categoria Air Conditioner

I documenti che otteniamo dal fabbricante del dispositivoFriedrich 2007 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Friedrich
- manuali per l’uso 2007
- schede prodotto Friedrich
- opuscoli
- o etichette energetiche Friedrich 2007
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Friedrich 2007.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Friedrich 2007, manuali di manutenzione, brevi manuali o manuali utente Friedrich 2007. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Friedrich 2007.

Manuali per l’uso simili

Manuale completo del dispositivo Friedrich 2007, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Friedrich 2007 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Friedrich 2007.

Il manuale per l’uso completo Friedrich, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Friedrich 2007 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Friedrich 2007, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Friedrich 2007 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Friedrich 2007 - che ci dovrebbe aiutare nei primi passi durante l'uso Friedrich 2007
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Friedrich 2007
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Friedrich 2007 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Friedrich 2007?

Utilizza il modulo sottostante

Se non hai risolto il problema con Friedrich 2007 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Friedrich 2007 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)