  • Omega Engineering OS137 - page 1

    OS137 SERIES Miniature Non-Contact Infrared T emperature Sensor/T ransmitter MADE IN omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info U ser ’ s Guide Shop online at ...

  • Omega Engineering OS137 - page 2

    Servicing Nor th America: U.S.A.: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: U.S.A. and Canad ...

  • Omega Engineering OS137 - page 3

    i OS137 Series Miniature Non-Contact Infrared T emperature Sensor/T ransmitter T able of Contents Section Page Caution & Safety Information ...................................................................... iii Safety W arnings and IEC Symbols .............................................................. iii Section 1 Introduction ........ ...

  • Omega Engineering OS137 - page 4

    OS137 Series Miniature Non-Contact Infrared Temperature Sensor/Transmitter ii T able of Figures Figure Description Page 2-1 General W iring Diagram ................................................................ 2 2-2 Alarm Output W iring Diagram .................................................... 2 3-1 Optical Field of V iew .................... ...

  • Omega Engineering OS137 - page 5

    OS137 Series Miniature Non-Contact Infrared Temperature Sensor/Transmitter iii CAUTION & SAFETY INFORMA TION If the equipment is used in a manner not specified in this manual, the protection provided by the equipment may be impair ed. The Installation category is one (1). There is no user r eplaceable fuse in this product. The output terminals ...

  • Omega Engineering OS137 - page 6

    1 SECTION 1 - INTRODUCTION The OS137 Series is a precision, miniatur e infrared transmitter . It measures temperature via non-contact, and pr ovides an analog output proportional to the measured temperatur e. The OS137 Series is offered in thr ee temperature ranges: 0 to 100ºC (32 to 212ºF), -18 to 260ºC (0 to 500ºF) and -18 to 538ºC (0 to 100 ...

  • Omega Engineering OS137 - page 7

    2 2 - ** means: -MA : 4 to 20 mA current output -V1 : 0 to 5 Vdc output -V2 : 0 to 10 Vdc output -K : K type thermocouple output -MVC : 10 mV/ºC output -MVF : 10 mV/ºF output The following table lists the optional accessories: 2.2 – Electrical Connection The shielded cable provides the power and output connections. Fig 2-1 shows the wiring diag ...

  • Omega Engineering OS137 - page 8

    3 Operation 3 SECTION 3 – OPERA TION 3.1 – Measuring T emperature Before starting to measur e temperature, make sure the following check list is met:  The power and output connections are made (Fig 2-1).  The target is lar ger than the optical field of view of the transmitter (Fig 3-1).  Use the Laser Sighting accessory (optional), to ...

  • Omega Engineering OS137 - page 9

    Operation 3 4 3.2 – Ambient T emperature The transmitter can operate in an ambient temperature of 0 to 70°C (32 to 158°F) without any water cool jacket. It can operate from 0 to 200°C (32 to 392°F) with the water cool jacket accessory , OS137-WC (Fig 3-6 & 3-7). It can operate up to 1 10°C (230°F) with air cooling. There is a warm up pe ...

  • Omega Engineering OS137 - page 10

    Figure 3-4. Air Purge Collar, OS137-AP Figure 3-5. Stainless Steel Housing Figure 3-6. Water/Air Cool Jacket, OS137-WC Operation 3 5 LIGHT DIAMOND KNURL 2.5 (0.1) WIDE DIMENSIONS mm (in) 1-20 UNEF 127 (5.0) 1.83 m (6 ft) 42.4 (1.67) 25.4 (1.0) DIMENSIONS mm (in) 128.6 (5.062) 7.9 (0.312) 41.2 (1.625) 1-20 UNEF 9.5 (3/8) 1-20 UNEF BUIL T -IN AIR PUR ...

  • Omega Engineering OS137 - page 11

    3.4 Alarm Setting The unit provides 0-100% alarm setpoint adjustment. Her e is an example of an alarm setting: • An OS137-3-MA (4/20 mA output), the alarm is to be set at 204°C (400°F) temperature. • Connect the alarm output as shown in Fig. 2-2. • Remove the End Cap to get to the Alarm Switch and the Alarm Adjust (Fig. 3-2). • Set the Sl ...

  • Omega Engineering OS137 - page 12

    SECTION 4 - LASER SIGHT ACCESSOR Y 4.1 – W arnings and Caution Y ou may receive harmful laser radiation exposure if you do not adhere to the warnings listed below: • USE OF CONTROLS OR ADJUSTMENTS OR PERFORMANCE OF PROCEDURES OTHER THAN THOSE SPECIFIED IN THIS GUIDE MA Y RESUL T IN HAZARDOUS RADIA TION EXPOSURE. • DO NOT LOOK A T THE LASER BE ...

  • Omega Engineering OS137 - page 13

    8 Figure 4-1. Laser Sighting Accessory, OS137-LS Figure 4-2. Laser Warning Label LASER W ARNING LABEL DC POWER JACK LED LASER POWER INDICA TOR LASER BEAM 22.2 (0.875) 50.8 (2.0) 38.1 (1.5) POWER CABLE ON/OFF SWITCH BA TTERY P ACK POWER SUPPL Y OS137 Dimensions mm (in) OUTPUT <1 mW, WAVELENGTH 630-670 nm, CLASS II (2) LASER PRODUCT. COMPLIES WITH ...

  • Omega Engineering OS137 - page 14

    9 SECTION 5 – SPECIFICA TIONS 5.1 - General T emperature Range: OS137-1 0 to 100ºC (32 to 212ºF) OS137-2 -18 to 260ºC (0 to 500ºF) OS137-3 -18 to 538°C (0 to 1000°F) Accuracy: @22ºC (72ºF) ambient 1.5% of Rdg or 2.0ºC (3.5ºF) whichever is greater Emissivity of 0.95 or greater Repeatability: 1% of Rdg or 1.0ºC (2.0ºF) whichever is grea ...

  • Omega Engineering OS137 - page 15

    10 5.2 - Laser Sight Accessory Laser W avelength (Color): 630 - 670 nm (red) Operating Distance: Up to 9.1 m (30 ft) Max. Laser Power Output: Less than 1 mW @ 22ºC (72°F) ambient European Classification: Class 2, EN60825-1/1 1.2001 FDA Classification: Class II Laser Product. Complies with 21 CFR 1040.10 Laser Beam Diameter: Less than 5 mm Beam Di ...

  • Omega Engineering OS137 - page 16

    Emissivity T able 6 11 Material Emissivity ( ε ) Aluminum – pure highly polished plate . . . . . . . . . . . . . . . . . . . . . . . . 0.04 to 0.06 Aluminum – heavily oxidized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.20 to 0.31 Aluminum – commercial sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Omega Engineering OS137 - page 17

    Emissivity Table 6 12 Material Emissivity ( ε ) Asbestos Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.96 Asphalt, tar , pitch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.95 to 1.00 Brick – red and rough . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Omega Engineering OS137 - page 18

    OS137 Series Miniature Non-Contact Infrared Temperature Sensor/Transmitter 6 13 NOTES: ...

  • Omega Engineering OS137 - page 19

    W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from d ate of p ur ch as e. OMEGA ’ s W ARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA ’ s ...

  • Omega Engineering OS137 - page 20

    M4015/0108 Where Do I Find Ever ything I Need for Pr ocess Measurement and Control? OM EGA…Of Course! Shop online at omega.com SM TEMPERA TURE   Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies   Wire: Thermocouple, RTD & Thermistor   Calibrators & Ice Point References   Recorders, Con ...

Fabbricante Omega Engineering Categoria Weather Radio

I documenti che otteniamo dal fabbricante del dispositivoOmega Engineering OS137 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Omega Engineering
- manuali per l’uso OS137
- schede prodotto Omega Engineering
- opuscoli
- o etichette energetiche Omega Engineering OS137
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Omega Engineering OS137.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Omega Engineering OS137, manuali di manutenzione, brevi manuali o manuali utente Omega Engineering OS137. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Omega Engineering OS137.

Manuali per l’uso simili

Manuale completo del dispositivo Omega Engineering OS137, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Omega Engineering OS137 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Omega Engineering OS137.

Il manuale per l’uso completo Omega Engineering, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Omega Engineering OS137 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Omega Engineering OS137, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Omega Engineering OS137 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Omega Engineering OS137 - che ci dovrebbe aiutare nei primi passi durante l'uso Omega Engineering OS137
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Omega Engineering OS137
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Omega Engineering OS137 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Omega Engineering OS137?

Utilizza il modulo sottostante

Se non hai risolto il problema con Omega Engineering OS137 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Omega Engineering OS137 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)