Manuale per l’uso Bunn LCR-3

27 pagine 1.84 mb
Scarica

Vai alla pagina of 27

Summary
  • Bunn LCR-3 - page 1

    LCR-3 HV INST ALLA TION & OPERA TING GUIDE BUNN-O-MA TIC CORPORA TION POST OFFICE BO X 3227 SPRINGFIELD , ILLINOIS 62708-3227 PHONE: (217) 529-6601 F AX: (217) 529-6644 T o ensure you have the latest revision of the Operating Manual, or to view the Illustrated Parts Catalog, Programming Manual, or Service Manual, please visit the Bunn-O-Matic w ...

  • Bunn LCR-3 - page 2

    2 41129 050511 BUNN-O-MA TIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) All equipment other than as specified below: 2 years parts and 1 year labor . 2) Electronic circuit and/or control boards: parts and labor for 3 years. 3) Compressors on refrigeration equipment: 5 years part ...

  • Bunn LCR-3 - page 3

    3 INTRODUCTION Always follow the Concentrate Manufacturer’ s for recommendations for proper Storage and Shelf Life. The product Flavor Profile is extended by the refrigerated cabinet featured in the LCR-3. This dispenser is designed to operate at ambient temperatures from 32°F (0°C) minimum to 104°F (40°C) maximum. 41129 060111 Warranty .... ...

  • Bunn LCR-3 - page 4

    4 Optional Field Wiring 120/208 V , 37.6 A, 7820 W 1PH, 3-Wire + GND, 60HZ 120/240 V , 43.2 A, 10400 W 1PH, 3-Wire + GND, 60HZ FOR USE ON INDIVIDUAL BRANCH CIRCUIT ONL Y 120/208Y V , 32.8 A, 12000 W 3PH, 4-Wire + GND, 60HZ 28181.0004 37947.0002 USER NOTICES Carefully read and follow all notices on the equipment and in this manual. They were written ...

  • Bunn LCR-3 - page 5

    5 ELECTRICAL REQUIREMENTS CAUTION: The dispenser must remain disconnected from power source until specified in Electrical Hook-Up. The LCR-3 HV is shipped configured for 3 Phase operation. The internal terminal block must be rewired for 208/240V – 1Phase applications, (see Optional Field Wiring Diagram). FIELD WIRING TERMINAL BLOCK DIAGRAM For ...

  • Bunn LCR-3 - page 6

    6 ELECTRICAL HOOK-UP CAUTION: Improper electrical installation will damage electronic components. 1. An electrician must provide electrical ser vice as specified in conformance with all local, state and federal electrical codes. 2. Using a voltmeter , check the voltage and color -coding of each conductor at the electrical source. 3. If plumbing is ...

  • Bunn LCR-3 - page 7

    7 INST ALLING THE PUMP TUBING (Refer to the T ubing Installation Instructions in side the cabinet door for details.) 1. Loosen the thumbscrew securing the tubing retainer plate to the pump housing. Set the retainer plate aside. 2. Depress the tension screw and remove it from the notch in the pump body , releasing the pump compression band. 3. Apply ...

  • Bunn LCR-3 - page 8

    8 OPERA TING CONTROLS AND INTERF ACE 1. Master ON/OFF Switch: Disconnects AC Power to the dispenser . 2. Hot Water Handle: Pull and Hold to dispense hot water manually . 3. Door Interlock Switch: Unit will not dispense product if the door is open. 4. LCD Display: Displays status, programming menus and fault messages. 5. Volume Selection: Rotate dia ...

  • Bunn LCR-3 - page 9

    9 INITIAL FILL & HEA T 1. Confirm the water supply is on. 2. Connect the dispenser to the power source. 3. T urn the Master ON/OFF Switch ON and select RUN on the Function Selector Switch. The LCD will display “T ank Filling – Please Wait!” and water will begin flowing into the tank. 4. Once the tank is full the dispenser will start hea ...

  • Bunn LCR-3 - page 10

    10 Rinse Alarm Feature Periodic rinsing of the mix chambers and dispense tips is essential for proper maintenance and optimum performance of the dispenser . The automated Rinse Alarm feature has three levels of operati on; see Programm ing the Dispenser to select the desired alarm mode. Alarm Level Alarm Mode Disabled None Warning Only “Rinse Req ...

  • Bunn LCR-3 - page 11

    11 BIB Empty Lockout Feature The dispenser can be set to not dispense product when the concentrate BIB is empty . T o enable this feature, first calibrate the Empty BIB Threshold ( refer to Field Calibrating the Empty BIB Warning ). Then enable the BIB Empty Lockout feature ( refer to the BIB Empty Lockout menu in Programming the Dispenser ). The ...

  • Bunn LCR-3 - page 12

    12 PROGRAMMING THE DISPENSER Press the Right Hidden Switch for 5 sec. to enter the programming menu. Use the Left and Right hidden switches to scroll through the menu screens. Select Exit to leave the programming function and return to normal operations. NOTE 1: Flashing menu items indicate which selection is active. NOTE 2: Values shown below are ...

  • Bunn LCR-3 - page 13

    13 ENTER P ASSWORD (-) 0 (+) SET P ASSWORD ? (-) 0 (+) 2 OR 3 PRODUCTS? (2) EXIT (3) SELECT UNITS ENG EXIT METRIC REFRIGERA TION ? ON EXIT OFF DEICE CYCLE TIME (-) 120 MIN (+) RINSE ALARM ? NO EXIT YES RINSE TIME ? (-) 12 HRS (+) RINSE LOCKOUT ? NO EXIT YES The following functions can be Password Protected. If you wish to prevent others from access ...

  • Bunn LCR-3 - page 14

    14 PROGRAMMING (Continued) BibEMPTY LOCKOUT NO EXIT YES BREW LOCKOUT ? NO EXIT YES ENERGY SA VER MODE NO EXIT YES E-SA VER IDLE TIME (-) 4 HRS (+) E-SA VER T ANK TEMP NO EXIT 140 Select (YES) to enable Select (YES) to enable Select (ON) to enable Use the (+) or (-) buttons to adjust the Idle Time Select OFF or 140° F (60°C) Select YES to Lockout ...

  • Bunn LCR-3 - page 15

    15 LCD DISPLA Y ACTION DESCRIPTION The following functions are for diagnostic and troubleshooting purposes and typically do not have to be adjusted. Contact your local service agent for assistance before making changes to these functions. PROGRAMMING (Continued) CAL LEFT PUMP ? LEFT CAL LF PUMP VOL (-) 58mL (+) CAL MIDDLE PUMP ? MIDDLE CAL MID PUMP ...

  • Bunn LCR-3 - page 16

    16 LCD DISPLA Y ACTION DESCRIPTION PROGRAMMING (Continued) XXOVERFLOW > 155 (-) EXIT (+) XX REFILL -> 155 (-) EXIT (+) WTR ST ART DELA Y (-) .15SEC (+) WTR STOP DELA Y (-) .15SEC (+) TEST SWITCHES ? UseSwitchT oT est TEST REFILL ? EXIT YES TEST HEA TER ? EXIT YES ENTER ASSET # (-) 000000 (+) SERIAL # LCR 0000000 VIEW F AUL TS? (-) EXIT (+) LA ...

  • Bunn LCR-3 - page 17

    17 LOADING THE CONCENTRA TE 1. Thoroughly mix concentrate by vigorously shaking the product Bag-In-Box (BIB). 2. Pull the BIB connector through the hole provided in the box. 3. Open the dispenser door and locate the appropriate left, middle or right BIB Adapter fitting. 4. Connect the Adapter fitting to the BIB. Make sure the locking mechanism is ...

  • Bunn LCR-3 - page 18

    18 FILLING CAMBROS OR OTHER LARGE CONT AINERS The dispenser is designed primarily for containers that will fit under the dispense tip. However , it may be used to fill larger containers (up to 5 Gal) by use of an extension hose on the dispense tip. Care must be taken to insure that the mixed product flows freely from the dispense tip into the co ...

  • Bunn LCR-3 - page 19

    19 CLEANING & PREVENT A TIVE MAINTENANCE General Cleaning and Sanitizing Procedures Note: The BUNN® Liquid Coffee Dispenser incorporates a “user selectable” rinse reminder feature and can be set to disable dispensing when it is time to rinse. See Programming Functions to activate this feature. Daily: RINSING & CLEANING 1. Select RINSE ...

  • Bunn LCR-3 - page 20

    20 REPLACING THE PUMP TUBING The pumps and tubing used in this dispenser are designed to give maximum per formance and long life. However , the tubes are a wear item and must be replaced periodically . How long the tubes last is dependent on usage and properties of the concentrate. Excessive wear will reduce the output of the pumps resulting in a w ...

  • Bunn LCR-3 - page 21

    21 DRAINING THE HOT W A TER T ANK CAUTION: The dispenser must be disconnected from the power source throughout these steps. 1. Disconnect the dispenser from the power source. 2. Shut off and disconnect the incoming water supply . 3. Remove the lower right access panel. 4. Pull out drain tube to empty into a sink or a container with a minimum of 18 ...

  • Bunn LCR-3 - page 22

    22 Check Pump & Flow Rate Calibration, refer to Field Calibration Procedures The calculated T arget RPM for the pump indicated is out of range ____ T ARGET RPM TOO HIGH !! Replace BIB, see Loading the Concentrate Check BIB Connector Fittings Check T ubing Installation Check Empty BIB Threshhold, see Field Calibrating the Epmty BIB Warning Conce ...

  • Bunn LCR-3 - page 23

    23 T roubleshooting (Continued) Service Required Service Required Replace T ubing 1. Pump Motor failure 2. RPM Sensor failure 3. T ubing pinched in rollers ____ PUMP F AUL T CHK PUMP WIRING CHK RPM SENSOR CHK TUBING AREA Check Pump & Flow Rate Calibration, refer to Field Calibration Procedures The calculated T arget RPM for the pump indicated i ...

  • Bunn LCR-3 - page 24

    24 EV AP TEMP SENSOR OUT OF RANGE CHECK FOR BAD CONNECTIONS CHECK WIRE FOR SHORTS COOL TEMP SENSOR OUT OF RANGE CHECK FOR BAD CONNECTIONS CHECK WIRE FOR SHORTS COOLER F AUL T! EV AP TEMP TOO HI CHECK EV AP F AN CHK EV AP SENSOR COOLING TIME TOO LONG CHECK AIR FIL TER CHECK COOLING UNIT Service Required Service Required Service Required Clean Air Fi ...

  • Bunn LCR-3 - page 25

    25 Field Calibration of the Concentrate Pumps / Dispenser Flow Rates The factory set Default Values for the Pump & Dispenser Flow Rates are ver y accurate and typically do not need to be field calibrated. However , if the mix ratio accuracy is ever in question, this procedure can be used to recalibrate the unit in the field. Equipment Require ...

  • Bunn LCR-3 - page 26

    26 Field Calibrating the Empty BIB W arning The dispenser will automatically display LEFT , MIDDLE or RIGHT BIB Empty when the corresponding Concentrate BIB is Empty . The Refill message is triggered when the Conductance Sensor reading drops below the minimum setting. The factory set minimum is 600 and should be correct for most locations. However ...

  • Bunn LCR-3 - page 27

    27 41129 110608 41172.0000C 10/08 © 2008 BUNN-O-MATIC CORPORA TION 208-240 VOL TS AC 3 WIRE + GND SINGLE PHASE 60HZ or 208-240 VOL TS AC 4 WIRE + GND THREE PHASE 60HZ J14-1 J14-7 J18-1 J18-9 J18-5 J18-7 J7-1 J7-5 J7-10 J2-1 J2 -8 J3-1 J3-6 J4-1 J4-5 J5-1 J5-3 J6-1 J6-5 J6-10 J6-15 J6-20 J1-1 J1-4 J15-1 J15-4 C O N T R O L P C B O A R D J8-1 J8-3 J ...

Fabbricante Bunn Categoria Beverage Dispenser

I documenti che otteniamo dal fabbricante del dispositivoBunn LCR-3 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Bunn
- manuali per l’uso LCR-3
- schede prodotto Bunn
- opuscoli
- o etichette energetiche Bunn LCR-3
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Bunn LCR-3.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Bunn LCR-3, manuali di manutenzione, brevi manuali o manuali utente Bunn LCR-3. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Bunn LCR-3.

Manuali per l’uso simili

Manuale completo del dispositivo Bunn LCR-3, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Bunn LCR-3 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Bunn LCR-3.

Il manuale per l’uso completo Bunn, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Bunn LCR-3 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Bunn LCR-3, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Bunn LCR-3 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Bunn LCR-3 - che ci dovrebbe aiutare nei primi passi durante l'uso Bunn LCR-3
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Bunn LCR-3
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Bunn LCR-3 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Bunn LCR-3?

Utilizza il modulo sottostante

Se non hai risolto il problema con Bunn LCR-3 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Bunn LCR-3 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)