Manuale per l’uso Vulcan-Hart ML 136043

24 pagine 0.16 mb
Scarica

Vai alla pagina of 24

Summary
  • Vulcan-Hart ML 136043 - page 1

    VULCAN-HART DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC WWW.VULCANHART.COM INST ALLA TION & OPERA TION MANUAL For additional information on Vulcan-Hart or to locate an authorized parts and service provider in your area, visit our website at www .vulcanhart.com F-35428 (2-06) ELECTRIC COUNTER CONVECTION STEAMERS 3600 NORTH POINT BLVD. BALTIMORE, M ...

  • Vulcan-Hart ML 136043 - page 2

    — 2 — C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS IMPORT ANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREP ARED FOR PERSONNEL QUALIFIED T O INST A LL THIS EQUIPMENT , WHO SHOULD PERFORM THE INITIAL FIELD ST ART -UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. W ARNING IMPROPER INST ALLA TION, ADJUSTMENT , A L TERA TION, SERVICE OR ...

  • Vulcan-Hart ML 136043 - page 3

    — 3 — C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS T ABLE OF CONTENTS IMPORTANT FOR YOUR SAFETY ....................................................................................................... 2 INTRODUCTION .............................................................................................................................. ...

  • Vulcan-Hart ML 136043 - page 4

    — 4 — C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS T ABLE OF CONTENTS (CONTINUED) START UP (PROFESSIONAL MODEL) .. . . . .. . . . . . . . . . . . . . . . . .. ............................................................... 11 OPERATION ......................................................................................................... ...

  • Vulcan-Hart ML 136043 - page 5

    — 5 — C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS INTRODUCTION GENERAL Vulcan convection steamers are produced with quality workmanship and material. Proper installation, usage and maintenance will result in many years of satisfactory performance. It is suggested that you thoroughly read this entire manual and carefully follow all of the ...

  • Vulcan-Hart ML 136043 - page 6

    — 6 — C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS LOCATION Allow space for plumbing and electrical connections. Minimum clearance is 6" (15.2 cm) on the back for proper air circulation. Allow adequate access for operating and servicing the steamer (36" at the front of the steamer, 15" (38 cm) above the steamer and 18" ...

  • Vulcan-Hart ML 136043 - page 7

    — 7 — C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS ELECTRICAL CONNECTION WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES. The wiring diagram is located on the right side panel as you face the steamer. This steamer is hard wired. Total Vol ...

  • Vulcan-Hart ML 136043 - page 8

    — 8 — C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS PLUMBING CONNECTIONS WARNING: PLUMBING CONNECTIONS MUST COMPLY WITH APPLICABLE SANITARY, SAFETY AND PLUMBING CODES. Water Requirements Proper water quality can improve the taste of the food prepared in the steamer, reduce liming in the steam generator and extend equipment life. Water condi ...

  • Vulcan-Hart ML 136043 - page 9

    — 9 — C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS Figure 2 VENT HOOD Local codes may require the steamer to be located under an exhaust hood. Information on the construction and installation of ventilating hoods may be obtained from Vapor Removal from Cooking Equipment, NFPA standard No. 96 (latest edition). ...

  • Vulcan-Hart ML 136043 - page 10

    — 10 — C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS OPERA TION Cooking Light (Professional model only) The cooking light indicates that the steamer is in the cooking cycle. Timer Set the cooking time (0 to 60 minutes). Steam cooking will begin when the door is closed. The cooking cycle will be interrupted if the door is open during the coo ...

  • Vulcan-Hart ML 136043 - page 11

    — 11 — C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS 8 . Close compartment door and let cooking cycle finish. When timer returns to 0, the buzzer will sound, signaling the end of the cooking cycle. To silence the buzzer, turn the timer dial to OFF. 9. To shut down the steamer, pull the handle to turn off and drain. Leave the compartment doo ...

  • Vulcan-Hart ML 136043 - page 12

    — 12 — C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS 7 . Open the compartment door and observe that steam supply to the compartment stops and that the cooking light is OFF. 8 . Close compartment door and let cooking cycle finish. When timer returns to 0, the buzzer will sound, signaling the end of the cooking cycle. To silence the buzzer, t ...

  • Vulcan-Hart ML 136043 - page 13

    — 13 — C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS CLEANING W ARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / T AGOUT PROCEDURES BEFORE CLEANING . COOKING COMPARTMENT DRAIN Keep compartment drain running freely. Inspect compartment drains daily for blockage. Remove any particles or debris from the perforated st ...

  • Vulcan-Hart ML 136043 - page 14

    — 14 — C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS Avoid rubbing with steel pads, wire brushes or scrapers that can leave iron deposits on stainless steel. Instead, use plastic scouring pads or soft cloths. For stubborn stains, use products such as Cameo, Talc or Zud First Impression. Always rub parallel to the polish lines or with the gr ...

  • Vulcan-Hart ML 136043 - page 15

    — 15 — C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS MAINTENANCE Items Required (not provided) • Deliming material • Funnel • Plastic or rubber gloves • Safety goggles or face shield • Measuring cup • 1-gallon container for mixing deliming solution • Petrol-Gel Lubricant or equivalent food- grade grease for coating deliming po ...

  • Vulcan-Hart ML 136043 - page 16

    — 16 — C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS 5 . Pour deliming solution into the steam generator slowly to avoid spillage. 6 . Remove funnel from delime port then rinse port with clean water. 7 . Lightly coat delime port threads with Petrol- Gel then install delime port cap. Cap must be installed and tightened securely at all times. ...

  • Vulcan-Hart ML 136043 - page 17

    — 17 — C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS DOOR GASKET If the door gasket is leaking due to a nick or cut, it must be replaced. Damage to the gasket sealing surface will cause steam leakage. DRAINING THE BOILER Drain the boiler at the end of each day to flush out minerals and minimize scale build-up. The generator drains automatic ...

  • Vulcan-Hart ML 136043 - page 18

    — 18 — C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS COOKING HINTS than 15 minutes of cooking time. When a cover is used, approximately one-third additional cooking time is necessary. Cooking time for frozen foods depends on the amount of defrosting required. If time permits, allow frozen foods to partially thaw overnight in a refrigerator. ...

  • Vulcan-Hart ML 136043 - page 19

    — 19 — C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS PRODUCTS TO BE COOKED IN SOLID PANS PRODUCT TIME (MINUTES) WEIGHT PER P AN Eggs, Scrambled 9 - 12 8 Doz. Rice, Long Grain (Cover with 4 cups water/lb.) 23 - 25 2 Lb. Pasta (Place perforated pan inside solid pan, cover with cold water) S paghetti – Regular/V ermicelli 10 - 15 Macaroni - ...

  • Vulcan-Hart ML 136043 - page 20

    — 20 — C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS PRODUCTS TO BE COOKED IN PERFORATED PANS PRODUCT TIME (MINUTES) WEIGHT PER P AN SEAFOOD Clams Frozen 9 - 12 3 Doz. Fresh, Cherrystone 4 - 6 3 Doz. King Crab, Frozen Claws 3 - 4 2 1/2 Lb. Legs 3 - 6 4 1/2 Lb. Lobster T ail, Frozen 5 - 6 10 Lb. Lobster , Live, 10" - 12" 4 - 5 4 Pe ...

  • Vulcan-Hart ML 136043 - page 21

    — 21 — C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS PRODUCT TIME (MINUTES) WEIGHT PER P AN VEGET ABLES (Cont’d.) Broccoli S pears, Frozen 6 - 8 4 Lb. S pears, Fresh 4 - 6 5 Lb. Flowerettes, Frozen 4 - 6 5 Lb. Cabbage, Fresh, 1/6 Cut 6 - 8 5 Lb. Carrots Baby Whole, Frozen 6 - 8 7 Lb. Crinkle Cut, Frozen 7 - 8 4 Lb. Sliced, Fresh 9 - 1 1 9 ...

  • Vulcan-Hart ML 136043 - page 22

    — 22 — C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS SYMPTOMS S teamer not steaming S teamer not heating/ steaming properly Door leaks W ater accumulates in compartment W ater not being supplied to steamer POSSIBLE CAUSES No main power source Power switch in OFF position (Professional) Handle out (OFF) position (Basic) W ater not being supp ...

  • Vulcan-Hart ML 136043 - page 23

    — 23 — C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS SER VICE AND P ARTS INFORMA TION To obtain service and parts information concerning this steamer, contact the Vulcan-Hart Service Agency in your area (refer to listing supplied with the steamer), or contact the Vulcan-Hart Service Department at the address or phone number shown on the fro ...

  • Vulcan-Hart ML 136043 - page 24

    — 24 — C24EA SERIES ELECTRIC COUNTER CONVECTION STEAMERS F-35428 (2-06) PRINTED IN U.S.A . ...

Fabbricante Vulcan-Hart Categoria Electric Steamer

I documenti che otteniamo dal fabbricante del dispositivoVulcan-Hart ML 136043 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Vulcan-Hart
- manuali per l’uso ML 136043
- schede prodotto Vulcan-Hart
- opuscoli
- o etichette energetiche Vulcan-Hart ML 136043
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Vulcan-Hart ML 136043.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Vulcan-Hart ML 136043, manuali di manutenzione, brevi manuali o manuali utente Vulcan-Hart ML 136043. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Vulcan-Hart ML 136043.

Manuali per l’uso simili

Manuale completo del dispositivo Vulcan-Hart ML 136043, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Vulcan-Hart ML 136043 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Vulcan-Hart ML 136043.

Il manuale per l’uso completo Vulcan-Hart, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Vulcan-Hart ML 136043 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Vulcan-Hart ML 136043, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Vulcan-Hart ML 136043 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Vulcan-Hart ML 136043 - che ci dovrebbe aiutare nei primi passi durante l'uso Vulcan-Hart ML 136043
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Vulcan-Hart ML 136043
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Vulcan-Hart ML 136043 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Vulcan-Hart ML 136043?

Utilizza il modulo sottostante

Se non hai risolto il problema con Vulcan-Hart ML 136043 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Vulcan-Hart ML 136043 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)