Manuale per l’uso Pentair P4

32 pagine 1.22 mb
Scarica

Vai alla pagina of 32

Summary
  • Pentair P4 - page 1

    Installation Data Installation Man u al PDA - Pool Digital Assistant W ARNING FOR YOUR SAFETY - This product must be installed and serviced by a pro fes sion al pool/spa service technician. The procedures in this manual must be followed ex act ly . Failure to follow warning notices and instructions may result in property damage, serious injury , or ...

  • Pentair P4 - page 2

    ...

  • Pentair P4 - page 3

    Page 3 T able of Contents Section 1. Important Safety Instructions .............. 4 Section 2. System Overview ................................... 6 2.1 Package Contents .................................... 6 2.2 System Component Speci fi cations and Dimensions ....................................... 7 2.3 Basic Plumbing .......................... ...

  • Pentair P4 - page 4

    Page 4 Section 1. Important Safety Instructions READ AND FOLLOW ALL INSTRUCTIONS LIRE LA NOTICE TECHNIQUE. All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes. When installing and using this electrical equipment, basic safety precautions should always be followed, including the followi ...

  • Pentair P4 - page 5

    Page 5 CAUTION A ground-fault circuit-interrupter must be provided if this device is used to control underwater lighting fixtures. The conductors on the load side of the ground-fault circuit-interrupter shall not occupy conduit, boxes, or enclosures containing other conductors unless the additional conductors are also protected by a ground-fault ci ...

  • Pentair P4 - page 6

    Page 6 Section 2. System Overview 2.1 Package Contents All Jandy AquaLink RS Systems come complete with the appropriate number of 3HP relays needed. Pool Digital Assistant (PDA) System Sub-Assembly Power Centers (Sold Separately) Standard Power Center (with mounting brackets) Sub-Panel Power Center (with mounting brackets and circuit breaker mounti ...

  • Pentair P4 - page 7

    Page 7 2.2 System Component Speci fi cations and Dimensions T able 1 Specifications (USA and Canada) Power Supply 120 V AC; 60 Hz; 3 A Contact Rating (Relays) High voltage - 25 A; 3HP @ 240 V AC 1½ HP @120 V AC 1500 W atts Incandescent Low V oltage - Class T wo, 1 A @ 24 V AC Service Switch All Circuits (located at Power Center in Service Mode) D ...

  • Pentair P4 - page 8

    Page 8 2.3 Basic Plumbing 2.3.1 Plumbing for Pool and Spa Combination The following plumbing diagrams illustrate simplified versions of standard plumbing setups for a pool and spa that share the same filter pump, filter , and heater . The intake and return Jandy V alve Actuators (JV As) turn si mul ta neous ly so when the Spa mode is selected on th ...

  • Pentair P4 - page 9

    Page 9 2.3.2 Booster Pump Pool Cleaner Plumbing Heater Filter Filter Pump Pool Intake Spa Intake Spa Return Pool Return Check V alve Spa Make-up Booster Pump 2.3.3 Non-Booster Pump Pool Cleaner Plumbing Filter Filter Pump Pool Intake Spa Intake Spa Return Pool Return Check V alve Spa Make-up Energy Filter Cleaner Line Heater ...

  • Pentair P4 - page 10

    Page 10 3.1 Power Center Mounting 1. The Power Center should be located at or near the equipment pad. Locate the Power Center at least fi ve (5) feet or more away from pool/spa and fi ve (5) feet off the ground. All na tion al, state, and local codes are applicable. NOTE For Canadian installations, the Power Center must be at least three (3) mete ...

  • Pentair P4 - page 11

    Page 1 1 3.2.3 Bonding the Power Center Install a bonding lug to the Power Center enclosure. Connect the bond lug, using a #8 solid copper core wire, to an approved earth ground (an approved ground stake, grid, or conducting metal water pipe buried to a sufficient depth). See Figure 3. 3.2.2 3HP (Standard) Relays For each piece of 240 volt equipmen ...

  • Pentair P4 - page 12

    Page 12 3.2.4 Underwater Lighting GFCI Wiring Figure 4. GFCI Installation for Underwater Lighting GFCI Outlet OPTIONAL Standard Power Center GFCI Outlet (Optional) OPTIONAL Sub-Panel Power Center 3.2.5 Jandy Pool and Spa Lights W iring The Jandy Pool and Spa Lights can be wired into the Jandy AquaLink RS control system to ensure simplified operatio ...

  • Pentair P4 - page 13

    Page 13 GFCI Black White Green 120V Jandy Light Ground Ground Neutral 120 V AC Power Supply Junction Box Figure 5. 120-V olt Jandy Pool and Spa Light Wiring Diagram Figure 6. 12-V olt Jandy Pool and Spa Light Wiring Diagram GFCI Ground Ground Neutral Black White Green 12V Jandy Light Black White Green 120V/12V Transformer 120 V AC Power Supply Junc ...

  • Pentair P4 - page 14

    Page 14 Figure 8. PDA J-Box Cable Connection to Power Center PCB Conduit Knockout for Low V oltage PDA J-box Wire Heyco Fittings for Low V oltage JV A and Sensor Wires Low V oltage Raceway High V oltage Knock outs for Conduit (DO NOT run any Low V oltage wires through these knockouts) 3.3 Low V oltage Wiring 3.3.1 Bezel Connection Plug the 24 V AC ...

  • Pentair P4 - page 15

    Page 15 3.4 Heater Connection The heater connection section applies to all heaters or heat pumps with thermostatic circuitry of 24 V AC or less (see pages 15 thru 17 for brand specific installation). NOTE If you are connecting a heater with thermostatic circuitry of 120 V AC or greater , do not connect to the green, 10-pin T erminal Bar . Instead, ...

  • Pentair P4 - page 16

    Page 16 3.4.4 Guidelines for a Gas Heater and a Jandy AE Series Heat Pump/Chiller Installation NOTE The following steps provide the procedure for installing a Jandy AE Series Heat Pump. 1. Install a fi xed resistor , with a value of 2.2K Ohms, in the solar sensor terminals #3 and #4 of the green, 10-pin terminal bar of the AquaLink RS Power Center ...

  • Pentair P4 - page 17

    Page 17 3.5 T emperature Sensors 1. Drill 3/8" hole in pipe between fi lter pump and fi lter and install the W ater T emperature Sensor per instructions (make certain the o-ring is in place). 2. Install Air T emperature Sensor outside the Power Center can, not in direct sunlight and away from motors and other heat sources. 3. Install Solar T ...

  • Pentair P4 - page 18

    Page 18 3.7.2 PDA Handheld Remote Installation 1. Remove the Handheld Remote from the packaging. 2. On the back of the Handheld Remote, loosen and remove the two (2) screws that secure the cover for the battery chamber (see Figure 19). 3. Install two (2) AA batteries. Ensure that the polarity is correct. 4. Re-install the cover for the battery cham ...

  • Pentair P4 - page 19

    Page 19 Section 4. System Startup 4.1 Handheld Remote Programming 4.1.1. Basic Programming Menu T o set a particular piece of equipment to turn on and off at predetermined times, highlight MENU and press SELECT (see Figure 23). Highlight PROGRAM and press SELECT . Use the UP or DOWN buttons to highlight the equipment (for example, Filter Pump) then ...

  • Pentair P4 - page 20

    Page 20 4.1.2 Set the T ime Menu T o set the time, highlight the MENU and press SELECT . Highlight SET TIME and press SELECT (see Figure 24). Use the UP or DOWN button to set the values. Press SELECT to continue. Pool/Spa Only - Highlight MENU and press SELECT . Highlight SET TEMP and press SELECT (see Figure 26). The message TEMP1 must be higher t ...

  • Pentair P4 - page 21

    Page 21 4.1.5 Set Freeze Pr otection Menu Highlight MENU and press SELECT . Highlight SYSTEM SETUP and press SELECT (see Figure 28). Highlight FREEZE PROTECT and press SELECT . Use the UP or DOWN button to change the temperature. Once the temperature is set press the SELECT button to move to the next screen to assign freeze protection to a selected ...

  • Pentair P4 - page 22

    Page 22 4.2 Restarting the System (Clear Memory) Menu T o remove all labeling, programming, assignments and temperature settings, highlight MENU and press SELECT . Highlight SYSTEM SETUP and press SELECT (see Figure 30). Highlight CLEAR MEMOR Y and press SELECT . Highlight CONTINUE and press SELECT . Use the UP or DOWN button to highlight YES or NO ...

  • Pentair P4 - page 23

    Page 23 Battery Backup A nine-volt battery is located at the power center . The battery keeps the clock running during a power outage so the time and date will be correct when power is restored. Programming will not be lost even if the battery is dead. Do not install the battery in the power center until the system is ready to operate. Battery will ...

  • Pentair P4 - page 24

    Page 24 4.4 PDA Handheld Remote Menu Flow Chart MENU PROGRAM SET TEMP POOL HEA T SP A HEA T SET TIME SET MONTH, DA Y , YEAR & TIME PDA OPTIONS SET AUT O-OFF BACKLIGHT ASSIGN HOTKEYS SYSTEM SETUP LABEL AUX TEMP CALIBRA TE SOLAR HEA T PRIORITY † ASSIGN JV As SP A SWITCH SERVICE INFO CLEAR MEMORY GENERAL LABELS LIGHT LABELS WTRF ALL LABELS (TYPE ...

  • Pentair P4 - page 25

    Page 25 Section 5. T roubleshooting 5.1 PDA Quick T roubleshooting Guide The AquaLink RS PDA will stop communicating anytime interference (such as a 900 MHz device) prevents a valid signal transmission. When communication is lost the PDA Handheld Remote will lock on the startup screen until a good link is again achieved, usually within a few sec on ...

  • Pentair P4 - page 26

    Page 26 Symptom Problem Possible Solution One button on the Four Function Remote does not operate. Check programming first. If the Four Function Remote is programmed correctly , the button may be shorted. NOTE If dip switch 1 (CLEANER) is on, button # 3 on the Four Function Remote will not operate when in spa mode unless this button is programmed t ...

  • Pentair P4 - page 27

    Page 27 Section 6. Power Center Wiring Diagram Aux. 4 Relay Aux. 7 Relay Aux. 5 R elay Aux. 6 Relay Filter Pump R e lay Aux. 3 R elay Aux. 1 Relay Li ne One Low V o l tage R a ceway ( do no t r un h igh volt age wi r e in thi s c ompar tment) Line Tw o Load One Load T wo Aux. 2 Relay Groun ding Ba r Wire Nut t o 120V AC Power System Power Intake JV ...

  • Pentair P4 - page 28

    Page 28 Section 7. Power Center PCB DIP Switch Settings IMPORT ANT Do not program equipment ON/OFF times until all DIP switches are set. 7.1 DIP Switch Functions DIP #1 ON- AUX 1 Controls Pool Cleaner If you installed a booster pump for a pool cleaner , the relay coil for the booster pump must be plugged into the AUX 1 relay socket. If a non-booste ...

  • Pentair P4 - page 29

    Page 29 7.2 DIP Switch Settings for Pool and Spa Combination DIP Switch # OFF ON 1 AUX1= any equipment AUX1= Pool Cleaner 2 AUX2= any equipment AUX2= Low Speed for a two-speed filter pump. Filter pump circuit becomes High Speed. 3 AUX3= any equipment AUX3= Spa Spillover effect- Combination controls only . 4 Heater cool down operates. Heater cool do ...

  • Pentair P4 - page 30

    Page 30 7.3 DIP Switch Settings for Pool or Spa Only DIP Switch # OFF ON 1 AUX1= any equipment AUX1= Pool Cleaner 2 AUX2= any equipment AUX2= Low Speed for a two-speed filter pump. Filter pump circuit becomes High Speed. 3 AUX3= any equipment No change 4 Heater cool down operates. Heater cool down disabled. 5 Normal operation Factory adjustment- wh ...

  • Pentair P4 - page 31

    Page 31 Section 8. General, W ater Featur e and Light Aux Labels General Labels Light Labels W aterfall Labels Aerator Air Blower Backwash Booster Pump Chem Feed Cleaner Color Wheel Drain Line Fan Fiber Optic Fill Line Filter Pump Floor System Fogger Fountain Heat Pump Heater Hi-E2 High Speed Home A/C Home Heat Jet Pump Lite Lamp Low Speed Mist Mus ...

  • Pentair P4 - page 32

    LIMITED W ARRANTY Thank you for purchasing Jandy ® pool and spa products. Jandy Pool Products, Inc. warrants all parts to be free from manufacturing defects in materials and workmanship for a period of one year from the date of retail purchase, with the following exceptions: • AquaLink ® RS units installed with Jandy ® Surge Protection Kits wi ...

Fabbricante Pentair Categoria PDAs & Smartphones

I documenti che otteniamo dal fabbricante del dispositivoPentair P4 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Pentair
- manuali per l’uso P4
- schede prodotto Pentair
- opuscoli
- o etichette energetiche Pentair P4
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Pentair P4.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Pentair P4, manuali di manutenzione, brevi manuali o manuali utente Pentair P4. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Pentair P4.

Manuali per l’uso simili

Manuale completo del dispositivo Pentair P4, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Pentair P4 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Pentair P4.

Il manuale per l’uso completo Pentair, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Pentair P4 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Pentair P4, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Pentair P4 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Pentair P4 - che ci dovrebbe aiutare nei primi passi durante l'uso Pentair P4
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Pentair P4
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Pentair P4 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Pentair P4?

Utilizza il modulo sottostante

Se non hai risolto il problema con Pentair P4 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Pentair P4 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)