Manuale per l’uso Mitsubishi Electronics PAC-YG60MCA

16 pagine 0.68 mb
Scarica

Vai alla pagina of 16

Summary
  • Mitsubishi Electronics PAC-YG60MCA - page 1

    Mitsubishi Electric Air Co nditioner Network System PI controller PAC-YG60MCA Installation/Instruction Manual Before using the PI controller, plea se read this installa tion/instruction manu al carefully to ensure proper operation. Keep this installation/instruction manual for futu re reference. Contents Page 1. Safety Precautions ............ .... ...

  • Mitsubishi Electronics PAC-YG60MCA - page 2

    1 • Before using the device, thorou ghly read the follo wing safety precautions and use as dir ected. • Hazards and levels o f danger tha t can occur du e to in correct handling are classified by the following symbols. • After reading this manual, keep this ma nual for future reference. Whe n the device is reinstalled or re paired, give this ...

  • Mitsubishi Electronics PAC-YG60MCA - page 3

    2 • Confirm that the box contains the following parts. * In addition to the parts mentioned above, other par ts need to be procured locally in order to operate this device. Furthermore , oth er Mitsubishi optional parts may be required depending on how the device is to be used. For details, refer to "6 Installation Method". 4-1. Product ...

  • Mitsubishi Electronics PAC-YG60MCA - page 4

    3 5 Example of System Configuration Note: • For the shield ground of the M-NET centralized control line for central control, use single-po int grounding at the power unit for the transmission line. However, when supplying ele ctric power to the M-NET ce ntralized control li ne from th e R410A se ries outdoor unit without using a power supply unit ...

  • Mitsubishi Electronics PAC-YG60MCA - page 5

    4 6-1. Parts to be Procured Locally Prepare the following parts to install th is device. [Parts to be Purchased Separately] [Recommended Pulse Specifications] Prepare a measuring instrumen t that measures the type of pulse sign als indicated in table below. 6 Installation Method Required Part Specification Unit fixing screws M4 screw × 4 Power sup ...

  • Mitsubishi Electronics PAC-YG60MCA - page 6

    5 6-2. Installation Procedure The PI controller PAC-YG60MCA does not ha ve a waterpro of structure. Be sure to install the PI controller inside a control panel tha t is located indoors. Prepare a control panel capable of storing this device such as the one shown in the figure. (Install the de vice in a control panel strong enough to withstan d a we ...

  • Mitsubishi Electronics PAC-YG60MCA - page 7

    6 (3) Refer to "7 Wiring Method " and connect the wires for the po wer line, M-NET transmission line, and input/outpu t signal lines. 7-1. Names of Parts PAC - SC50KUA M-NET N FG L -V +V Diagram Image (Installed within a Contro l Panel) * The wiring in the diagram has bee n simplified. M-NET Pulse Input Power line PI controller Caution: P ...

  • Mitsubishi Electronics PAC-YG60MCA - page 8

    7 7-2. Connecting the Power Line and M-NET Transmission Line CN16 V+/V -/FG CN17 A/B/S S FG M- NET S / B / A (M1) (M2) U U R Tightening to rque for term inal screws: 1 N·m Connect the device to a power supply unit (PAC-SC50KUA) for the transmissio n line or an ou tdoor unit (either a centralized control line or indoor control line can be connected ...

  • Mitsubishi Electronics PAC-YG60MCA - page 9

    8 7-3. Connecting the Signal Lines • Separate ly procure items such as te rminal blocks and cables locally. • The maximum wire length is 10 0 m. However, since th e use of long wires makes th e device susceptible to noise, using wires shorter than 10 m is recommended. (1) Pulse input (non-volta ge a contact) * To use these, various settings nee ...

  • Mitsubishi Electronics PAC-YG60MCA - page 10

    9 After completing the p rocedures described in "6 Installation Method" and "7 Wiring Method", set the initial settings in accordance with the procedure descr ibed below. (1) M-NET address settin gs (2) Use the dip switches to select functions. Select the function required fo r each input channel to be used. The switch assignme ...

  • Mitsubishi Electronics PAC-YG60MCA - page 11

    10 Set the dip switches for fu nction selection according to the system to be used. At the time of shipment, all dip switches are set to OFF and the M-NET ad dress is set to 01. *1: When using a system controller (G(B)-50A or T G-2000A), select the "SC setting" and set the pulse we ight value settings from a system controller. If set to a ...

  • Mitsubishi Electronics PAC-YG60MCA - page 12

    11 The LEDs of this device indicate the pulse in put status and error status of this device. 10-1.Display Content List *1: If a communication error occurs, switch to "Communication Err o r Status Display". Changing SW08-1 from ON to OFF masks the "C o mmunication Error Status Display" for 10 seconds so that the i nput status of ...

  • Mitsubishi Electronics PAC-YG60MCA - page 13

    12 Use the following pr ocedure to co nfirm operation of the system. (1) Configure the settings of this devi ce and the system controllers while refe rring to "8 Initial Setting Procedure". (2) Perform an operation from a system co ntroller and confirm whether a connected device can be operat ed normally. (1) Confirm that th ere is no inc ...

  • Mitsubishi Electronics PAC-YG60MCA - page 14

    ...

  • Mitsubishi Electronics PAC-YG60MCA - page 15

    ...

  • Mitsubishi Electronics PAC-YG60MCA - page 16

    WT04973X01 This product is designed and int ended fo r use in the residential, commercial and light-i ndustr ial environment. This product at hand is based on the following EU regulations: • Low Voltage Directive 73/23/EEC • Electrom agnetic Compatibility Directive 2004/108/EC NOTE: This equipment has been tested and foun d to comply with the l ...

Fabbricante Mitsubishi Electronics Categoria Air Conditioner

I documenti che otteniamo dal fabbricante del dispositivoMitsubishi Electronics PAC-YG60MCA possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Mitsubishi Electronics
- manuali per l’uso PAC-YG60MCA
- schede prodotto Mitsubishi Electronics
- opuscoli
- o etichette energetiche Mitsubishi Electronics PAC-YG60MCA
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Mitsubishi Electronics PAC-YG60MCA.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Mitsubishi Electronics PAC-YG60MCA, manuali di manutenzione, brevi manuali o manuali utente Mitsubishi Electronics PAC-YG60MCA. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Mitsubishi Electronics PAC-YG60MCA.

Manuale completo del dispositivo Mitsubishi Electronics PAC-YG60MCA, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Mitsubishi Electronics PAC-YG60MCA dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Mitsubishi Electronics PAC-YG60MCA.

Il manuale per l’uso completo Mitsubishi Electronics, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Mitsubishi Electronics PAC-YG60MCA - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Mitsubishi Electronics PAC-YG60MCA, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Mitsubishi Electronics PAC-YG60MCA che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Mitsubishi Electronics PAC-YG60MCA - che ci dovrebbe aiutare nei primi passi durante l'uso Mitsubishi Electronics PAC-YG60MCA
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Mitsubishi Electronics PAC-YG60MCA
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Mitsubishi Electronics PAC-YG60MCA in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Mitsubishi Electronics PAC-YG60MCA?

Utilizza il modulo sottostante

Se non hai risolto il problema con Mitsubishi Electronics PAC-YG60MCA con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Mitsubishi Electronics PAC-YG60MCA è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)