    Decorative Gas Appliance Installation and Homeowners Operating Instructions PLEASE READ THIS MANUAL BEFORE INST ALLING AND USING APPLIANCE IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty . W ARNING: If the in ...

  • Vermont Casting NVC39 - page 2

    2 NVC Series B- V e nt 20000194 T able of Contents Thank you and Congratulations on your purchase of a CFM Corporation fireplace. PLEASE READ THE INST ALLA TION & OPERA TING INSTRUCTIONS BEFORE USING THE APPLIANCE IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may re ...

  • Vermont Casting NVC39 - page 3

    3 NVC Series B- V e nt 20000194 Installation & Operating Instructions This gas appliance should be installed by a qualified installer in accordance with local building codes and with current CSA-B149.1 Natural Gas and Propane In- stallation Code. If the unit is being installed in a mobile home, the installation should comply with the current C ...

  • Vermont Casting NVC39 - page 4

    4 NVC Series B- V e nt 20000194 A D N M N A B S G H J Gas Line Access - 2" Dia. Gas Line Access 2" Dia. Finished W all Thickness 6" Flue Rough Opening Height Rough Opening Width Rough Opening Depth C Electrical Cable Knock-out - 1" Dia. E L F K P Q R Electrical Box Knock-out - 2" Dia. Electrical Cable Knock-out 1" Dia. ...

  • Vermont Casting NVC39 - page 5

    5 NVC Series B- V e nt 20000194 Clearance to Combustibles Appliances T op .......................................................... 0” (0 mm) Bottom ..................................................... 0” (0 mm) Side ......................................................... 0” (0 mm) Back .................................................... ...

  • Vermont Casting NVC39 - page 6

    6 NVC Series B- V e nt 20000194 Gas Specifications 1. Choose the unit location. 2. Place the unit into position and secure it to the floor with 1 ¹⁄₂ ” (38mm) screws, or nails. The holes to secure the unit to floor are located just behind the access door grille on the left and right side of the unit. 3. Frame in the fireplace with a head ...

  • Vermont Casting NVC39 - page 7

    7 NVC Series B- V e nt 20000194 Gas Line Installation When purging gas line the fornt glass must be removed. Purging gas lines must com- ply with ANSI Z223.1/NFP A 54 in USA and CSA B149.1 in Canada. The gas pipeline can be brought in through the right or left side of the appliance, as well as the bottom. Knock- outs are provided at convenient loca ...

  • Vermont Casting NVC39 - page 8

    8 NVC Series B- V e nt 20000194 The fireplace, when installed, must be electrically connected and grounded in accordance with local codes or , in the ab- sence of local codes, with the current CSA C22.1 Canadian Electrical Code For USA installations follow the local codes and the national electrical code ANSI/NFP A No. 70. It is strongly suggested ...

  • Vermont Casting NVC39 - page 9

    9 NVC Series B- V e nt 20000194 Fig. 9 Firestop/draftstop positions. Ceiling Installation FP384  FIRESTOP 11/21/96 adapted from IGF53 Attic Installation Firestop position when area abov e ceiling is an attic. Firestop position when area abov e ceiling is NOT an attic. (Firestop/draftstop  appearances may  vary. Only 1 firestop  re ...

  • Vermont Casting NVC39 - page 10

    10 NVC Series B- V e nt 20000194 Operating Instructions Only glass approved by CFM Corporation should be used on this fireplace. • The use of any non-approved replacement glass will void all product warranties. • Care must be taken to avoid breakage of the glass. • Do not operate appliance with glass front removed, cracked or broken. • Rep ...

  • Vermont Casting NVC39 - page 11

    1 1 NVC Series B- V e nt 20000194 6. Place the top logs onto the locator notches. Ensure that the logs a re secure. (Fig. 12) 7. Place ember material. See "Ember Material Place- ment" section. NVC36 NVC39 NVC43 Front Left Log BB6 BC5 BD6 Front Right Log BB7 BC6 BD7 Rear Log BE5 BC7 BD8 T op Left Log BB9 BC8 BD9 T op Right Log BB10 BC9 BD1 ...

  • Vermont Casting NVC39 - page 12

    12 NVC Series B- V e nt 20000194 T est Chimney Draw A "Chimney Draw" test must be made before the instal- lation is complete. 1. Close all doors and windows in the home and start exhaust fans in the kitchen and bathroom. 2. Light unit and operate for 5 minutes. 3. Hold an ignited match, cigarette, or smoke match in front of the unit. Refe ...

  • Vermont Casting NVC39 - page 13

    13 NVC Series B- V e nt 20000194 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to "OFF". Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. Turn of f all electrical power to the fireplace. 3. For MN/MP/TN/TP appliances ONL Y , go on to Step 4. For RN/RP ap ...

  • Vermont Casting NVC39 - page 14

    14 NVC Series B- V e nt 20000194 V ent Safety Switch This fireplace incorporates the use of a V ent Safety Shut-off Switch. The sensor and wiring are factory installed and should not be removed or altered during installation. In the event of total flue blockage the system will detect the increased heat buildup and will automatically shut down the ...

  • Vermont Casting NVC39 - page 15

    15 NVC Series B- V e nt 20000194 T roubleshooting FP649 Turn gas supply off Turn ON/OFF Switch to call for heat. NO NO NO NO NO NO NO Spark across Ignitor Sensor gap Power to module (24V nominal) YES YES YES YES YES YES YES Turn gas on Pilot burner lights? Spark stops when pilot is lit? Main Burner lights? Replace Module START Line Voltage (120VAC) ...

  • Vermont Casting NVC39 - page 16

    16 NVC Series B- V e nt 20000194 Remove glass door before service work Honeywell VS8421 ST ART CHECK Gas Supply On Pilot Lights With Piezo Ignitor • Lockout Has Engaged. Wait 60 Seconds And Try Again. • For Spark At Electrode While Depressing Piezo 1/8" Gap T o Pilot Hood Needed. • All Wiring Connections • Replace Piezo Ignitor • Sup ...

  • Vermont Casting NVC39 - page 17

    17 NVC Series B- V e nt 20000194 T roubleshooting FP396 Gas Supply On Supply Line Hooked Up Shutoff Valve Open NO NO NO NO Lockout Has Engaged. Wait 60 Seconds and Try Again. Piezo Nut Tight for Good Ground. For Spark at Electrode While Depressing Piezo (Red Button) - 1/8" Gap to Pilot Hood Needed. All Wiring Connections Replace Piezo Ignitor ...

  • Vermont Casting NVC39 - page 18

    18 NVC Series B- V e nt 20000194 Cleaning the Standing Pilot Control System The burner and control system consists of • burner tube • gas orifice • pilot assembly • thermopile • millivolt gas valve Most of these components may require only an oc- casional checkup and cleaning and some may require adjustment. If repair is necessary , it s ...

  • Vermont Casting NVC39 - page 19

    19 NVC Series B- V e nt 20000194 FP772A Replacement Parts nvc 8/25/98 31 28 29 26 6a/b 4a/b 5 36 35 34 1a 1b 1c 1d 1e NVC43 Logs 1 27 37 2 3 1a 1b NVC36 1d 1e 1c 1e 1c 1a 1b 1d NVC39 1 18 25 17a/b 22 19                                      ...

  • Vermont Casting NVC39 - page 20

    20 NVC Series B- V e nt 20000194 NVC36/39/43 (continued) Ref. Description NVC36 NVC39 NVC43 6a. Orifice Front Burner-Nat. See Rating Plate 6b. Orifice Front Burner-LP See Rating Plate 7a. Pilot Assy- SIT T op Convertible, LP 10002265 10002265 10002265 7b. Pilot Assy - SIT T op Convertible, Nat. 10002264 10002264 10002264 8a. Orifice Pilot - Nat. ...

  • Vermont Casting NVC39 - page 21

    21 NVC Series B- V e nt 20000194 Optional Accessories Fan Kits FK12 Fan Assembly 1. Open louvre assembly bottom. 2. Install FK12 fan in back of unit between hearth sup- ports. 3. Secure fan on velcro strips. 4. Power to the fan can be supplied by plugging the supply lead into a conveniently located wall socket or by using a hard-wired EB-1 connecto ...

  • Vermont Casting NVC39 - page 22

    22 NVC Series B- V e nt 20000194 Remote Controls Optional remote control units are available to control different functions of the appliance. Model Function(s) Controlled MRC1 ON/OFF MRC2 ON/OFF and T emperature MRC3 ON/OFF and T emperature control with a digital and a programmable 24 hour clock IMT Wall mounted thermostat control Ceramic Refractor ...

  • Vermont Casting NVC39 - page 23

    23 NVC Series B- V e nt 20000194 FP1 195 Arched door front 2/27/02 djt FP1 196 Fig. 28 Arched door front in place. EB-1 Electrical Box Standard on electronically controlled models, the EB-1 is also available for other fireplaces. Installation should be completed by a qualified service person. Decorative Frame T rims A selection of decorative f ...

  • Vermont Casting NVC39 - page 24

    24 NVC Series B- V e nt 20000194 ...

  • Vermont Casting NVC39 - page 25

    25 NVC Series B- V e nt 20000194 ...

  • Vermont Casting NVC39 - page 26

    26 NVC Series B- V e nt 20000194 ...

  • Vermont Casting NVC39 - page 27

    27 NVC Series B- V e nt 20000194 BASIC W ARRANTY CFM Corporat ion (hereinafter referred to collectively as the Company) warrants that your new V ermont Castings or Majestic Gas Fireplace/ Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions and limitations. EXT ...

  • Vermont Casting NVC39 - page 28

    2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www .cfmcorp.com CFM Corporation Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency (%) NVC36RN 29.4 NVC36RP 29.4 NVC36RFN 29.4 NVC36RFP 29.4 NVC36EN 28.5 NVC36EP 28.5 NVC39RN 26.4 NVC39RP 26.4 NVC39RFN 26.4 NVC39RFP 26.4 NVC39EN 25.6 NVC39EP 25.6 NVC43RN ...

Fabbricante Vermont Casting Categoria Indoor Fireplace

I documenti che otteniamo dal fabbricante del dispositivoVermont Casting NVC39 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Vermont Casting
- manuali per l’uso NVC39
- schede prodotto Vermont Casting
- opuscoli
- o etichette energetiche Vermont Casting NVC39
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Vermont Casting NVC39.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Vermont Casting NVC39, manuali di manutenzione, brevi manuali o manuali utente Vermont Casting NVC39. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Vermont Casting NVC39.

Manuali per l’uso simili

Manuale completo del dispositivo Vermont Casting NVC39, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Vermont Casting NVC39 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Vermont Casting NVC39.

Il manuale per l’uso completo Vermont Casting, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Vermont Casting NVC39 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Vermont Casting NVC39, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Vermont Casting NVC39 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Vermont Casting NVC39 - che ci dovrebbe aiutare nei primi passi durante l'uso Vermont Casting NVC39
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Vermont Casting NVC39
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Vermont Casting NVC39 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Vermont Casting NVC39?

Utilizza il modulo sottostante

Se non hai risolto il problema con Vermont Casting NVC39 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Vermont Casting NVC39 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)