    BFM 30 BFM 50 BFM 80 MODELS INST ALLA TION INSTRUCTIONS AND USERS MANUAL UNITED KINGDOM CLOSED COMBUSTION W A TER HEA TER ...

  • A.O. Smith BFM 50 - page 2

    2 INTRODUCTION Read the installation instructions before installing the water heater. Read the user-instructions before lighting the water heater. If these instructions are not followed carefully, this may lead to explosion and/or fire and can cause material damages and/or physical harm. Installation and commissioning should be carried out by a reg ...

  • A.O. Smith BFM 50 - page 3

    3 CONTENTS PAGE 1 . GENERAL 1.1 Water heater description .................................................................................................... ................. 5 1.2 Technical safety equipment .................................................................................................. .............. 6 1.2.1 Gas control ....... ...

  • A.O. Smith BFM 50 - page 4

    4 Figure 1 1 ) TOP-BOX 9 ) VENTILATION FAN 2 ) AIR PROVING SWITCH 10 ) ANODE 3 ) TEMPERATURE REGULATOR 1 1) FLUE TUBES ON/OFF SWITCH 12 ) FLUE BAFFLE RESET-KNOB 13 ) DIAPHRAGM 4 ) BURNER CONTROLLER 14 ) INSULATION 5 ) GAS VALVE 1 5 ) BURNER 6 ) MANIFOLD / INJECTORS 16 ) AIR DIFFUSION PLATE 7 ) PILOT BURNER 17 ) CONDENSATE DRAIN 8 ) HORIZONTAL AIR I ...

  • A.O. Smith BFM 50 - page 5

    5 1. GENERAL 1.1 Description of the appliance Construction and fitting out of the storage appliance comply with the European Standard for gas fired hot water storage appliances for sanitary use (EN89). The appliance thereby satisfies the requirements of the European Directive for Gas Appliances, and is therefore entitled to bear the CE mark. The BF ...

  • A.O. Smith BFM 50 - page 6

    6 1.2 Technical safety equipment 1.2.1 Gas control The water heaters are equipped with a gas control valve which regulates the flow of gas to the burner. The combination gas control is equipped with a safety valve, gas control valve, pilot safety valve and burner control (on a standard natural gas setting) 1.2.2 Control box For safety purposes, wat ...

  • A.O. Smith BFM 50 - page 7

    7 Figure 3 - Differential pressure switch Figure 2 - Positioning ventilation ...

  • A.O. Smith BFM 50 - page 8

    8 1. 3 Technical description 1.3.1 Measurements See figure 4 All dimensions in mm, rounded up to the nearest 5 mm. Size BFM 30 BFM 50 BFM 80 A 1995 1995 2020 B 1795 1795 1820 C 600 600 600 D 520 520 525 E 600 600 590 F 1640 1640 1655 G 1360 1360 1360 H 630 630 625 K 710 710 710 L 1000 1000 1000 M 755 755 755 N 80/125 100/150 130/200 1 Cold water in ...

  • A.O. Smith BFM 50 - page 9

    9 Figure 4 I MD- 0057 -R0 ...

  • A.O. Smith BFM 50 - page 10

    10 Description Unit BFM 30 BFM 50 BFM 80 DATA NATURAL GAS G 20 Nominal gas inlet pressure mbar 20 20 20 Burner pressure mbar 12.5 12.5 12.5 Input k W 2 9 4 7 7 5 Output to water kW 2 7 4 2 6 8 Gas consumption* m3/h 3. 0 4 .7 7. 9 Diameter main injector m m 2.60 2.50 2.70 Diameter injector ignition burner m m 0.56 / 0.41 0.56 / 0.41 0.56 / 0.41 Heat ...

  • A.O. Smith BFM 50 - page 11

    11 I MD- 0065 2 . FOR THE INSTALLER If possible, use a trolley or fork-lift truck to move the water heater. Always move the water heater in an upright position. 2. 1 Installation instructions The following distances should be observed: - Sides of the water heater: 100 cm (free space for the accessibility of the hand holes) - Rear of the water heate ...

  • A.O. Smith BFM 50 - page 12

    12 I MD- 0066 -R0 Depending on the length and insulation of the water piping and the water demand frequency, it may be necessary to install a circulation system on the drain cock. The return pipe of the circulation piping can be fitted on the top of the drain cock after the sealing plug has been removed (see figure 6). Unvented To install an A.O. S ...

  • A.O. Smith BFM 50 - page 13

    13 I MD- 0059 Depending on the water demand pattern (e.g., small amounts frequently), it may be necessary to circulate the water in the water heater to prevent temperature stratification. Therefore, we recommend that a circulation system is installed in the event of such demand patterns (see figure 8). Kits are available from A.O. Smith or our dist ...

  • A.O. Smith BFM 50 - page 14

    14 Flue configuration / horizonal discharge BFM-unit Measurement BFM 30 BFM 50 BFM 80 min. max. min. max. min. max. A 0 7000 0 7000 0 7000 B 0 7000 0 7000 0 7000 A +B < 7000 < 7000 < 7000 All measurements are in mm. The following applies for the horizontal pipe: slope of at least 5 mm per metre of pipe to the water heater. NB. Measurements ...

  • A.O. Smith BFM 50 - page 15

    15 I MD- 0061 I MD-00 62 Figure 10 and 11 - Roof discharge. All measurements are in mm. The following applies for the horizontal pipe: slope of at least 5 mm per metre of pipe to the water heater. A maximum of 2 bends (45° or 90°) may be used with Flue configurations roof discharge BFM-unit Measurement BFM 30 BFM 50 BFM 80 min. max. min. max. min ...

  • A.O. Smith BFM 50 - page 16

    16 2.1.6 Electrical connection All electrical connections must be carried out by a registered electrical contractor to the relevant regulations. The BFM must be connected to a supply voltage by means of a permanent electric connection and have a feeder cable not less than 3 x 1,0 mm². Supply voltage Supply network Mínimum fuse frequency required ...

  • A.O. Smith BFM 50 - page 17

    17 Figure 12 - Electrical connection diagram BFM I MD 0055 R1 ...

  • A.O. Smith BFM 50 - page 18

    18 Figure 13 - Connection diagram control-column. D) Transformer 230 E) Air proving switch F) EMC single phase filter G ) RESET knob H) Thermostat frost K) Thermostat regulation L ) Switch ON/OFF M ) Thermostat overheat N) Thermostat high limit P) Automatic burner controller R) Relay X ) Plastic connector strip Y ) Earth terminal block I MD- 0063 ...

  • A.O. Smith BFM 50 - page 19

    19 2. 2 Turning the water heater on 2.2.1 Filling the water heater 1. Assemble the drain-off tap and check that it is closed. 2. Open the cold water tap to the water heater and open a l l taps on hot water outlet points to vent them. The heater is filled as soon as cold water pours out of all outlet points. 3. Close all taps at hot water draining p ...

  • A.O. Smith BFM 50 - page 20

    20 Figure 14 - Checking the gas pressures 2. 5 Checking the gas pressures The nominal load has been set at the correct value in the factory. A further check of the pressure should be carried out during the commissioning of the unit. A dangerous situation can occur if the following instructions are not followed carefully. Setting the nominal load is ...

  • A.O. Smith BFM 50 - page 21

    21 2. 6 Conversion to another gas Important: Install a gas valve suitable for the type of gas to be used. If the water heater has to function on a gas category (LP or natural gas) other than the gas set as standard (ex works), the water heater must be converted to the applicable gas category with the associated conversion kit(s). Only an accredited ...

  • A.O. Smith BFM 50 - page 22

    22 2 . 7 Maintenance The water heater must be checked and cleaned regularly (at least once a year) by an accredited installer, so that proper operation is guaranteed. The bar burners, control and safety valves must also be checked. (see figure 17). 2.8 Anode The life of the anode is determined by the quality and the quantity of water flowing throug ...

  • A.O. Smith BFM 50 - page 23

    23 2.10 Condensation If the water heater has been filled with cold water or if the hot water usage has been very high, normally condensation of the flue gasses will occur on the cold sides of the combustion chamber and the flue tubes. The water drops will fall on to the burner bed which can cause a hissing sound. This is normal and will disappear a ...

  • A.O. Smith BFM 50 - page 24

    24 3 . FOR THE USER 3.1. Instructions for use Installation and commissioning of the water heater should only be undertaken by a registered installer. 3.1.2 Filling the water heater 1. Assemble the drain-off tap and ensure it is closed; 2. Open the cold water tap to the water heater and open a l l taps on hot water drain-off points to vent them. The ...

  • A.O. Smith BFM 50 - page 25

    25 No or insufficient hot water. Check whether the electricity is turned on. Check whether the gas supply is turned on. Does the ON/OFF switch light up? Does the RESET switch light up? Push RESET switch up to three times Is the water heater in operation? Consult your installer. 4 . FAULT FINDING 4. 1 Fault finding USER Problem solved no yes yes yes ...

  • A.O. Smith BFM 50 - page 26

    26 4. 2 Fault finding INSTALLER Check if ON/OFF switch is in position 1 ? Put ON/OFF switch in position 1 . Problem solved yes Is the water heater in operation? Problem solved yes Is the water heater in operation? Problem solved yes Is the water heater in operation? yes no no no no no yes See detailed fault finding no Does the ON/OFF switch light u ...

  • A.O. Smith BFM 50 - page 27

    27 4. 3 Detailed fault finding INSTALLER no Check voltage present at connection 1 . Reinstate voltage supply no Ensure connections correct, if yes replace FILTER Ensure connections correct, if yes replace ON/OFF switch Check voltage present after FILTER Check voltage present at gate 3 ON/OFF switch Check voltage present at gate 11 and 12 CONTROL TH ...

  • A.O. Smith BFM 50 - page 28

    28 Ensure connections correct, if yes replace MAXIMUM THERMOSTAT Check voltage present at GATE 12 MAXIMUM THERMOSTAT? Check voltage present at GATE 1 BURNER AUTOMATION S4560D 1150? Check voltage present at GATE 8 BURNER AUTOMATION Is VENTILATING FAN in operation? Check voltage present at GATE 7, BURNER AUTOMATION Check voltage present at GATE 3 AIR ...

  • A.O. Smith BFM 50 - page 29

    29 yes yes yes yes yes yes yes yes no no no no no no no Check voltage present at GATE 12 ECO Check voltage present at GATE 11 BURNER AUTOMATION Pressure H higher then 300 PA? Pressure L less then 0 PA ? Check voltage present at GATE 2 BURNER AUTOMATION Does the RESET switch light up? Check voltage present at GATE 10 BURNER AUTOMATION Ensure connect ...

  • A.O. Smith BFM 50 - page 30

    30 Re-instate gas supply and reset water heater Water heater in in operation? Gas supply present? Problem solved IONISATION PROBLEMS. Carry out 3 RESET cycles to make sure the pilot is provided with gas. Check gasconnections towards the pilot burner. Carry out one more RESET cycle. If no operation is valid replace the entire PILOT BURNER assy. RESE ...

  • A.O. Smith BFM 50 - page 31

    31 5 . WARRANTY The following conditions form the guarantee agreement between A.O. Smith Water Products Company (the warrantor) and the owner of the water heater. 5. 1 Guarantee in general If within one year of the original installation date of the water heater any part or component other than the tank shall prove upon examination by the warrantor ...

  • A.O. Smith BFM 50 - page 32

    32 0305 664 R0 ...

Fabbricante A.O. Smith Categoria Water Heater

I documenti che otteniamo dal fabbricante del dispositivoA.O. Smith BFM 50 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici A.O. Smith
- manuali per l’uso BFM 50
- schede prodotto A.O. Smith
- opuscoli
- o etichette energetiche A.O. Smith BFM 50
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso A.O. Smith BFM 50.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione A.O. Smith BFM 50, manuali di manutenzione, brevi manuali o manuali utente A.O. Smith BFM 50. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto A.O. Smith BFM 50.

Manuali per l’uso simili

Manuale completo del dispositivo A.O. Smith BFM 50, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare A.O. Smith BFM 50 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti A.O. Smith BFM 50.

Il manuale per l’uso completo A.O. Smith, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale A.O. Smith BFM 50 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice A.O. Smith BFM 50, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per A.O. Smith BFM 50 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo A.O. Smith BFM 50 - che ci dovrebbe aiutare nei primi passi durante l'uso A.O. Smith BFM 50
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del A.O. Smith BFM 50
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio A.O. Smith BFM 50 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su A.O. Smith BFM 50?

Utilizza il modulo sottostante

Se non hai risolto il problema con A.O. Smith BFM 50 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con A.O. Smith BFM 50 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)