Manuale per l’uso American Dryer Corp. AD-120ES II

70 pagine 0.55 mb
Scarica

Vai alla pagina of 70

Summary
  • American Dryer Corp. AD-120ES II - page 1

    ADC Part No. 113313 For replacement parts, contact the reseller from which the dryer was purchased or American Dryer Corporation 88 Currant Road Fall River MA 02720-4781 Telephone: (508) 678-9000 / Fax: (508) 678-9447 E-mail: techsupport@amdry.com www.amdry.com WARNING: For your safety the information in this manual must be followed to minimize the ...

  • American Dryer Corp. AD-120ES II - page 2

    Retain This Manual In A Safe Place For Future Reference American Dryer Corporation products embody advanced concepts in engineering, design, and safety. If this product is properly maintained, it will provide many years of safe, efficient, and trouble-free operation. ONLY qualified technicians should service this equipment. OBSERVE ALL SAFETY PRECA ...

  • American Dryer Corp. AD-120ES II - page 3

    IMPORTANT YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPLY AND THE GAS SUPPLY OR THE STEAM SUPPLY BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING, ADJUSTING, INSTALLATION, OR TESTING OF ANY EQUIPMENT PER OSHA (Occupational Safety and Health Administration) STANDARDS. CHILDREN SHOULD NOT BE ALLOWED TO PLAY ON ...

  • American Dryer Corp. AD-120ES II - page 4

    WARNING The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJURY OR FIRE COULD RESULT. IMPORTANT PLEASE OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment and/or specified in the installation manual included with the dryer. WARNING DRYER MUST NEVER BE OPERATED WITHOUT THE LINT FILTE ...

  • American Dryer Corp. AD-120ES II - page 5

    Table of Contents SECTION I IMPORTANT INFORMATION .......................................................................... 3 A. Receiving and Handling ............................................................................................................... 3 B. Safety Precautions ............................................................. ...

  • American Dryer Corp. AD-120ES II - page 6

    SECTION VI ROUTINE MAINTENANCE ............................................................................ 44 A. Cleaning ................................................................................................................................... 44 B. Adjustments ............................................................................. ...

  • American Dryer Corp. AD-120ES II - page 7

    3 SECTION I IMPORTANT INFORMATION A. RECEIVING AND HANDLING The dryer is shipped in a protective stretch wrap cover with protective cardboard corners and top cover (or optional box) as a means of preventing damage in transit. Upon delivery, the dryer and/or packaging, and wooden skid should be visually inspected for shipping damage. If any damage w ...

  • American Dryer Corp. AD-120ES II - page 8

    4 B. SAFETY PRECAUTIONS WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury, or loss of life. WARNING: The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJURY OR FIRE COULD RESUL ...

  • American Dryer Corp. AD-120ES II - page 9

    5 WARNING: DO NOT use heat for drying articles that contain plastic, foam, sponge rubber, or similarly textured rubber materials. Drying in a heated basket (tumbler) may damage plastics or rubber and may be a fire hazard. 7. A program should be established for the inspection and cleaning of lint in the heating unit area, exhaust ductwork, and insid ...

  • American Dryer Corp. AD-120ES II - page 10

    6 MAXIMUM CAPACITY (DRY WEIGHT) 120 lbs. 54.4 kg BASKET (TUMBLER) DIAMETER 44-1/2” 113 cm BASKET (TUMBLER) DEPTH 42-1/2” 107.9 cm BASKET (TUMBLER) MOTOR 3/4 HP 0.560 kw BLOWER MOTOR 3 HP 2.238 kw DOOR OPENING (DIAMETER) 31-3/8” 79.7 cm BASKET (TUMBLER) VOLUME 38.2 cu. ft. 1.08 cu. m. DRYERS PER 20'/40' CONTAINER 3/7 DRYERS PER 45&ap ...

  • American Dryer Corp. AD-120ES II - page 11

    7 NOTE: ADC reserves the right to make changes in specifications at any time without notice or obligation. NOTE : Operating height of steam dryer is 89-inches (226.1 cm). E X H AU S T D UC T D I A . D I M . "A" D I M . "B" G A S A ND E LE C T R I C 14" 35.5 cm 11-1/4" 28.6 cm 9-1/2" 24.1 cm S T E A M 16" 40.6 ...

  • American Dryer Corp. AD-120ES II - page 12

    8 B. COMPONENT IDENTIFICA TION 1. Dryer Front View Illus. No. Description 1 Microprocessor Control/Keyboard (touch pad) Panel Assembly (controls) 2 Control (top access) Door Assembly 3 Main Door Assembly 4 Lint Door Assembly 5 Lint Drawer 6 Wire Diagram (located behind control door) 7 Top Console (module) Assembly ...

  • American Dryer Corp. AD-120ES II - page 13

    9 2. Dryer Rear View Illus. No. Description 1 Basket (tumbler) Drive Motor Assembly 2 Blower Motor Mount Assembly 3 Impellor (fan/blower) Assembly 4 Idler Bearing Mount Assembly 5 Basket (tumbler) Bearing Mount Assembly 6* Electric Service Relay Box 7 Heating Unit 8 Data Label and Installation Label * Electric service connections are made in this b ...

  • American Dryer Corp. AD-120ES II - page 14

    10 SECTION III INSTALLATION PROCEDURES Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.1- LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA NO. 70-LATEST EDITION (National Electrica ...

  • American Dryer Corp. AD-120ES II - page 15

    11 CAUTION: This dryer produces combustible lint and must be exhausted to the outdoors. Every 6 months, inspect the exhaust ducting and remove any lint build up. B. UNP ACKING/SETTING UP Remove protective shipping material (i.e., plastic wrap, and/or optional shipping box) from dryer. IMPORTANT: Dryer must be transported and handled in an upright p ...

  • American Dryer Corp. AD-120ES II - page 16

    12 2. If more headroom is needed when moving dryer into position, the top console (module) may be removed. a. To Remove Top Console (Module) 1) Disconnect the ground wire (A) at the rear upper left hand corner of dryer. 2) Remove the eight (8) sets of nuts and washers (B) holding the console (module) to base. 3) Open the control door/control panel ...

  • American Dryer Corp. AD-120ES II - page 17

    13 3. Exhaust Transition Piece (Gas and Electric Only!) a. Inside the basket (tumbler) of this dryer is an exhaust transition piece that must be installed on the outlet of the exhaust before any further venting is connected: 1) Remove the exhaust transition piece from the basket (tumbler) and place it on the exhaust outlet. 2) Using the screws prov ...

  • American Dryer Corp. AD-120ES II - page 18

    14 C. DR YER ENCLOSURE REQUIREMENTS Even though a 12-inch (30.48 cm) clearance is acceptable, it is recommended that the rear of the dryer be positioned approximately 2 feet (0.60 meters) from the nearest obstruction (i.e., wall) for ease of installation, maintenance, and service. Bulkheads and partitions should be made from noncombustible material ...

  • American Dryer Corp. AD-120ES II - page 19

    15 D. FRESH AIR SUPPLY REQUIREMENTS When the dryer is operating, it draws in room air, heats it, passes this air through the basket (tumbler), and exhausts it out of the building. Therefore, the room air must be continually replenished from the outdoors. If the make-up air is inadequate, drying time and drying efficiency will be adversely affected. ...

  • American Dryer Corp. AD-120ES II - page 20

    16 IMPORTANT: Make-up air must be provided from a source free of dry cleaning solvent fumes. Make-up air that is contaminated by dry cleaning solvent fumes will result in irreparable damage to the motors and other dryer components. NOTE: Component failure due to dry cleaning solvent fumes will VOID THE WARRANTY . E. EXHAUST REQUIREMENTS 1. General ...

  • American Dryer Corp. AD-120ES II - page 21

    17 ALL ductwork should be smooth inside with no projections from sheet metal screws or other obstructions, which will collect lint. When adding ducts, the ducts to be added should overlap the duct to which it is connected. ALL ductwork joints must be taped to prevent moisture and lint from escaping into the building. Additionally, inspection doors ...

  • American Dryer Corp. AD-120ES II - page 22

    18 2. Single Dryer Venting Where possible, it is suggested to provide a separate exhaust duct for each dryer. The exhaust duct should be laid out in such a way that the ductwork travels as directly as possible to the outdoors with as few turns as possible. It is suggested that the use of 90° turns in ducting be avoided; use 30° and/or 45° angles ...

  • American Dryer Corp. AD-120ES II - page 23

    19 IMPORTANT: For extended ductwork runs, the cross section area of the duct can only be increased to an extent. Maximum proportional ductwork runs cannot exceed 20 feet (6.09 meters) more than the original limitations of 20 feet (6.09 meters) with two (2) elbows. When the ductwork approaches the maximum limits as noted in this manual, a profession ...

  • American Dryer Corp. AD-120ES II - page 24

    20 The main duct may be any shape or cross-sectional area, so long as the minimum cross section area is provided. The illustrations on page 21 show the minimum cross section area for multiple dryer round or square venting. These figures must be increased 10 square inches (64.51 square centimeters) when rectangular main ducting is used, and the rati ...

  • American Dryer Corp. AD-120ES II - page 25

    21 ADG-120ES II and ADE-120ES II (Gas and Electric) with 14” (35.56 cm) Diameter 2,150 cfm (60.88 cmm) Exhaust Connection at Common Duct ADS-120ES II (Steam) with 16” (40.64 cm) Diameter 2,150 cfm (60.88 cmm) Exhaust Connection at Common Duct ...

  • American Dryer Corp. AD-120ES II - page 26

    22 F. ELECTRICAL INFORMATION 1. Electrical Requirements It is your responsibility to have ALL electrical connections made by a properly licensed and competent electrician to assure that the electrical installation is adequate and conforms to local and state regulations or codes. In the absence of such codes, ALL electrical connections, material, an ...

  • American Dryer Corp. AD-120ES II - page 27

    23 2. Electrical Service Specifications * AWG Stranded Type Wire ... size wire as per National Electrical Code or local codes. (Motor lead type wire is recommended). IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is affixed to the left side panel/wall area behind the control door. In the case of 208 VAC o ...

  • American Dryer Corp. AD-120ES II - page 28

    24 IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is affixed to the left side panel/wall area behind the control door. In the case of 208 VAC or 240 VAC, the supply voltage must match the electric service specifications of the data label exactly . WARNING: 208 VAC AND 240 VAC ARE NOT THE SAME . Any damage ...

  • American Dryer Corp. AD-120ES II - page 29

    25 NOTE: ADC has discontinued making 80 Kw dryers. This information is for dryers in the field. IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is affixed to the left side panel/wall area behind the control door. In the case of 208 VAC or 240 VAC, the supply voltage must match the electric service specific ...

  • American Dryer Corp. AD-120ES II - page 30

    26 3. Electrical Connections NOTE: A wiring diagram is included with each dryer and is affixed to the rear upper right guard/panel of the dryer. The only electrical input connections to the dryer are the 3-phase (3Ø) power leads (L1, L2, and L3), GROUND, and in the case of 4 wire service, the neutral. Providing local codes permit, power connection ...

  • American Dryer Corp. AD-120ES II - page 31

    27 4. Grounding A ground (earth) connection must be provided and installed in accordance with state and local codes. In the absence of these codes, grounding must conform to applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION, or in Canada, the installation must conform to applicable Canada Standards: Canadian El ...

  • American Dryer Corp. AD-120ES II - page 32

    28 G . GAS INFORMA TION It is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the gas plumbing installation is adequate and conforms to local and state regulations or codes. In the absence of such codes, ALL plumbing connections, materials, and workmanship must conform to the applicable requireme ...

  • American Dryer Corp. AD-120ES II - page 33

    29 2. Technical Gas Data a. Gas Specifications b. Gas Connections Inlet connection ------------- 1-inch N.P.T. Inlet supply size ------------- 1-inch N.P.T. (minimum) Btu/hr input (per dryer) ----- 375,000 (94,500 kcal/hr) 1) Natural Gas Regulation is controlled by the dryer's gas valve's internal regulator. Incoming supply pressure must ...

  • American Dryer Corp. AD-120ES II - page 34

    30 3. Piping/Connections ALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LATEST EDITION, or in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION (for General Installation and Gas Plumbing), as well as local codes and ordinances and must be done by ...

  • American Dryer Corp. AD-120ES II - page 35

    31 IMPORTANT: The dryer and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). NOTE: The dryer must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of ...

  • American Dryer Corp. AD-120ES II - page 36

    32 H. STEAM INFORMA TION It is your responsibility to have ALL steam plumbing connections made by a qualified professional to assure that the installation is adequate and conforms to local and state regulations or codes. IMPORTANT: Failure to comply with the requirements stipulated in this manual can result in component failure, which will VOID THE ...

  • American Dryer Corp. AD-120ES II - page 37

    33 a. The pressure of the condensate in the steam supply will cause water hammer and subsequent heat exchanger (steam coil) failure. The steam supply connection into the main supply line must be made within a minimum 12-inch (30.48 cm) riser. This will prevent any condensate from draining towards the dryer. b. The steam supply piping to the dryer m ...

  • American Dryer Corp. AD-120ES II - page 38

    34 C O M P R E S S E D A I R S U P P L Y A I R P R E SS UR E Normal 80 PSI 5.52 bars Minimum Supply 70 PSI 4.83 bars Maximum Supply 90 PSI 6.21 bars Shaded areas are stated in metric equivalents 4. Steam Damper Air System Connections The dryer is manufactured with a pneumatic (piston) damper system, which requires an external supply of compressed a ...

  • American Dryer Corp. AD-120ES II - page 39

    35 6. Steam Damper Air Piston (Flow Control) Operation Adjustment System Although the damper operation was tested and adjusted prior to shipping at 80 PSI (5.51 bars ) , steam damper operation must be checked before the dryer is put into operation. Refer to page 34 for instructions to check steam damper system operation. If damper air adjustment is ...

  • American Dryer Corp. AD-120ES II - page 40

    36 I. PREP ARA TION FOR OPERA TION The following items should be checked before attempting to operate the dryer: 1. Read ALL “ CAUTION ,” “ WARNING ,” and “ DIRECTION ” labels attached to the dryer. 2. Check incoming supply voltage to be sure that it is the same as indicated on the dryer data label located on the left side panel/wall ar ...

  • American Dryer Corp. AD-120ES II - page 41

    37 J. PREOPERATIONAL TESTS ALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or due to marginal location (installation) conditions. 1. Turn on electric power to the dryer. 2. Make sur ...

  • American Dryer Corp. AD-120ES II - page 42

    38 2) The dryer is equipped with a Direct Spark Ignition (DSI) system, which has internal diagnostics. If ignition is not established after the first attempt, the heat circuit DSI module will “LOCKOUT” until it is manually reset. To reset the DSI system, open and close main door and restart dryer (press the “ENTER/START” key). NOTE : During ...

  • American Dryer Corp. AD-120ES II - page 43

    39 b. Dual Timer Dryer Models 1) Spin and stop times are adjustable at the reversing timer. BASKET COA TING The basket (tumbler) is treated with a protective coating. We suggest dampening old garments or cloth material with a solution of water and nonflammable mild detergent and tumbling them in the basket (tumbler) to remove this coating. 8. Each ...

  • American Dryer Corp. AD-120ES II - page 44

    40 L. OPERA TING INSTRUCTIONS NOTE: Before attempting to start the dryer make sure that the main door is closed and the lint drawer is securely in place. 1. To Start The Dryer a. Microprocessor Controller (Computer) Dryer Models 1) Display will read “FILL” (meaning no cycle in progress). 2) Press the letter on the keyboard (touch pad) correspon ...

  • American Dryer Corp. AD-120ES II - page 45

    41 SECTION IV SER VICE/P AR TS INFORMA TION A. SER VICE 1. Service must be performed by a qualified trained technician, service agency, or gas supplier. If service is required, contact the reseller from whom the ADC equipment was purchased. If the reseller cannot be contacted or is unknown, contact the ADC Service Department for a reseller in your ...

  • American Dryer Corp. AD-120ES II - page 46

    42 SECTION V WARRANTY INFORMATION A. RETURNING W ARRANTY CARDS 1. Before any dryer leaves the ADC factory test area, a warranty card is placed on the back side of the main door glass. These warranty cards are intended to serve the customer where we record the individual installation date and warranty information to better serve you should you file ...

  • American Dryer Corp. AD-120ES II - page 47

    43 2. Each part must be tagged with the following information: a. Model number and serial number of the dryer from which part was removed. b. Nature of failure (be specific). c. Date of dryer installation. d. Date of part failure. e. Specify whether the part(s) being returned is for a replacement, a credit, or a refund. NOTE: If a part is marked fo ...

  • American Dryer Corp. AD-120ES II - page 48

    44 SECTION VI ROUTINE MAINTENANCE A. CLEANING A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from various areas of the dryer, as well as throughout the ductwork system. The frequency of cleaning can best be determined from experience at each location. Maximum operating efficiency is dependent ...

  • American Dryer Corp. AD-120ES II - page 49

    45 STEAM DRYERS Clean the steam coil fins. We suggest using compressed air and a vacuum cleaner with brush attachment. WARNING: When cleaning steam coil fins, be careful not to bend the fins. If fins are bent, straighten by using a fin comb, which is available from local air conditioning supply houses. 90 DAYS Remove lint from around basket (tumble ...

  • American Dryer Corp. AD-120ES II - page 50

    46 B. ADJUSTMENTS 7 DA YS AFTER INST ALLA TION AND EVER Y 6 MONTHS THEREAFTER Inspect bolts, nuts, screws (bearing setscrews), and nonpermanent gas connections (unions, shutoff valves, orifices, and grounding connections). Motor and drive belts should be examined. Cracked or seriously frayed belts should be replaced. Tighten loose V-belts when nece ...

  • American Dryer Corp. AD-120ES II - page 51

    47 SECTION VII TROUBLESHOOTING IMPORTANT: YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPLY AND THE GAS SUPPLY OR THE STEAM SUPPLY BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING, ADJUSTING, INSTALLATION, OR TESTING OF ANY EQUIPMENT PER OSHA (Occupational Safety and Health Administration) STANDARDS. The infor ...

  • American Dryer Corp. AD-120ES II - page 52

    48 2. Failed arc suppressor (A.S.) board. 3. Failed drive motor. 4. Failed microprocessor controller (computer). C. Drive motor (reversing) operates in one (1) direction ONL Y ...stops and restarts in same direction... 1. Failed drive motor contactor (relay). 2. Failed arc suppressor (A.S.) board. 3. Failed microprocessor controller (computer). D. ...

  • American Dryer Corp. AD-120ES II - page 53

    49 G. Both drive motor and blower motor are not operating ( DO NOT start)...microprocessor controller (computer) motor indicator dots are on... 1. Failed arc suppressor (A.S.) board. 2. Failed microprocessor controller (computer). H. Both drive motor and blower motor run a few minutes and then stop...microprocessor controller (computer) display con ...

  • American Dryer Corp. AD-120ES II - page 54

    50 f. Failed 24 VAC transformer. K. Microprocessor controller (computer) will not accept any keyboard (touch pad) entries, i.e., light emitting diode (L.E.D.) display reads “FILL” and when keyboard (touch pad) entries are selected, the L.E.D. display continues to read “FILL”... 1. Failed keyboard (touch pad) label assembly. 2. Failed microp ...

  • American Dryer Corp. AD-120ES II - page 55

    51 5. Failed Direct Spark Ignition (DSI) ignitor/flame-probe assembly. 6. Failed microprocessor controller (computer). P. No heat (for GAS MODEL ONLY)...ignitor sparks, burner goes on and off right away... 1. DSI ignitor/flame-probe is out of adjustment...reposition closer to the flame area. 2. Sail switch is fluttering... a. Lint screen is dirty. ...

  • American Dryer Corp. AD-120ES II - page 56

    52 3. Failed lint compartment automatic (225º F [107.2 ° C]) safety thermostat. 4. Failed oven contactor (relay). 5. Failed microprocessor controller (computer). S. Dryer operates but is taking too long to dry... 1. Exhaust ductwork run too long or is undersized...back pressure must be no less than 0 and cannot exceed 0.3 inches (0.74 mb) water c ...

  • American Dryer Corp. AD-120ES II - page 57

    53 3. Back draft damper is sticking in partially closed position. U. Dryer is making scraping noise at basket (tumbler) area... 1. Check for object caught in basket (tumbler)/wrapper area. 2. Basket (tumbler) is out of proper alignment... a. Check both vertical alignment and lateral alignment. b. Check gap between front panel and basket (tumbler).. ...

  • American Dryer Corp. AD-120ES II - page 58

    54 5. Failed heat timer. 6. Failed dual timer relay. B. Drive motor ( ONL Y ) is not operating ( does not start)... 1. Failed drive motor contactor. 2. Failed reversing timer (for Reversing Models ONLY) . 3. Failed drive motor. C. Blower (impellor/fan) motor ( ONL Y ) is not operating ( does not start)... 1. Tripped or failed overload. 2. Failed bl ...

  • American Dryer Corp. AD-120ES II - page 59

    55 3. Failed lint compartment automatic (225º F [107.2° C]) safety thermostat circuit. 4. Failed Direct Spark Ignition (DSI) module (burner control). 5. Failed DSI ignitor/flame-probe assembly. 6. Failed heat selector switch. ELECTRIC MODELS 1. Fault in sail switch circuit... a. Sail switch is out of adjustment and/or has failed. b. Sail switch i ...

  • American Dryer Corp. AD-120ES II - page 60

    56 H. Dryer operates but is taking too long to dry load... 1. Heating unit cycling on hi-limit thermostat (for GAS AND ELECTRIC MODELS ONLY) . 2. Steam damper binding in partially open position (for STEAM MODELS ONLY) . 3. Lint and/or dust accumulation on steam coil fins (for STEAM MODELS ONLY) . 4. Housekeeping... a. Lint screen and lint compartme ...

  • American Dryer Corp. AD-120ES II - page 61

    57 5. Failed hi-limit thermostat. 6. Failed oven contactor (relay) - for ELECTRIC MODELS ONLY . J. Condensation on main door glass... 1. Too long, undersized, or improperly installed ductwork. 2. Dryer connected to common exhaust duct with another dryer, and no back draft damper was installed in customer furnished ductwork. 3. Location furnished ba ...

  • American Dryer Corp. AD-120ES II - page 62

    58 SECTION VIII DA T A LABEL INFORMA TION A. DA T A LABEL Contact American Dryer Corporation When contacting American Dryer Corporation, certain information is required to insure proper service/parts information from ADC . This information is on the data label located on the left side panel/wall area behind the control door. When contacting ADC ple ...

  • American Dryer Corp. AD-120ES II - page 63

    59 THE DATA LABEL 1. MODEL NUMBER The model number is an ADC number, which describes the size of the dryer and the type of heat (gas, electric, or steam). 2. SERIAL NUMBER The serial number allows ADC to gather information on your particular dryer. 3. MANUFACTURING CODE NUMBER The manufacturing code number is a number issued by ADC, which describes ...

  • American Dryer Corp. AD-120ES II - page 64

    60 SECTION IX REVERSING TIMER SPIN/DWELL ADJUSTMENTS Timer models have an electric reversing timer in the electric service box, which is located in the upper left rear area of the dryer. Both the dwell (stop) time and basket (tumbler) spin time are adjustable by mode selection switches located on the electronic timer (as noted in the illustration b ...

  • American Dryer Corp. AD-120ES II - page 65

    61 SECTION X PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT COMPONENTS 1. Microprocessor Controller (Computer) Board a. Upon completing installation of the replacement microprocessor controller (computer) board, reestablish power to the dryer. b. Start the drying cycle. c. Verify that the motor(s) and the heat indicator dots, in the microprocessor c ...

  • American Dryer Corp. AD-120ES II - page 66

    62 e. Open main door. The dryer must stop and ALL indicator lights on the back side of the microprocessor controller (computer) board must go out. (Refer to the illustration on the previous page.) f. Try to restart the dryer with the main door open. g. The microprocessor controller (computer) board’s light emitting diode (L.E.D.) display must rea ...

  • American Dryer Corp. AD-120ES II - page 67

    63 3. For Direct Spark Ignition (DSI) System Models Manufactured With ADC M odule Part No. 880815 a. Upon completing installation of the replacement DSI module, reestablish power to the dryer. b. Starting the drying cycle. c. The ignition DSI module’s light emitting diode (L.E.D.) indicator will light “red” for up to approximately 1.5-seconds ...

  • American Dryer Corp. AD-120ES II - page 68

    64 SECTION XI BURNER AND BASKET (TUMBLER)/LINT CHAMBER MANUAL RESET HI-LIMIT INSTRUCTIONS I M P O R T A N T MANUAL RESET HI-LIMIT INSTRUCTIONS FOR TIMER OR PHASE 5 WITHOUT HEA T F AUL T (GAS MODELS ONL Y) This dryer was manufactured with a burner and basket (tumbler)/lint chamber burner manual reset hi-limit thermostat. If either burner manual rese ...

  • American Dryer Corp. AD-120ES II - page 69

    65 I M P O R T A N T MANUAL RESET HI-LIMIT INSTRUCTIONS FOR TIMER OR PHASE 5 WITHOUT HEA T F AUL T (ELECTRIC OR STEAM MODELS ONL Y) This dryer was manufactured with a burner and basket (tumbler)/lint chamber burner manual reset hi-limit thermostat. If the manual reset thermostat is open prior to the start of the drying cycle, or during the cycle, t ...

  • American Dryer Corp. AD-120ES II - page 70

    ADC 113313 1 - 02/07/01-25 2 - 02/12/01-25 3 - 04/06/01-25 4* 06/27/01-25 ...

Fabbricante American Dryer Corp. Categoria Clothes Dryer

I documenti che otteniamo dal fabbricante del dispositivoAmerican Dryer Corp. AD-120ES II possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici American Dryer Corp.
- manuali per l’uso AD-120ES II
- schede prodotto American Dryer Corp.
- opuscoli
- o etichette energetiche American Dryer Corp. AD-120ES II
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso American Dryer Corp. AD-120ES II.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione American Dryer Corp. AD-120ES II, manuali di manutenzione, brevi manuali o manuali utente American Dryer Corp. AD-120ES II. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto American Dryer Corp. AD-120ES II.

Manuale completo del dispositivo American Dryer Corp. AD-120ES II, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare American Dryer Corp. AD-120ES II dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti American Dryer Corp. AD-120ES II.

Il manuale per l’uso completo American Dryer Corp., dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale American Dryer Corp. AD-120ES II - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice American Dryer Corp. AD-120ES II, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per American Dryer Corp. AD-120ES II che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo American Dryer Corp. AD-120ES II - che ci dovrebbe aiutare nei primi passi durante l'uso American Dryer Corp. AD-120ES II
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del American Dryer Corp. AD-120ES II
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio American Dryer Corp. AD-120ES II in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su American Dryer Corp. AD-120ES II?

Utilizza il modulo sottostante

Se non hai risolto il problema con American Dryer Corp. AD-120ES II con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con American Dryer Corp. AD-120ES II è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)