  • Omega Engineering DRN-PS-750 - page 1

    ...

  • Omega Engineering DRN-PS-750 - page 2

    Servicing North America: USA: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1 TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: USA and Canada: Sales Servic ...

  • Omega Engineering DRN-PS-750 - page 3

    1. General Information and Features 2 2. Applicable Standards 3 3. Installation and Removal 4 4. Input and Output Connections 8 5. Specifications 9 5.1 PS T ype Labeling 5.2 Size & W eight 5.3 Mounting 5.4 T emperature Ranges 5.5 Input Range 5.6 Input Current Surge Protection 5.7 Output V oltage 5.8 Output Current 5.9 Output Ripple 5.10 T emper ...

  • Omega Engineering DRN-PS-750 - page 4

    The compact DRN power supplies are designed to supply well-regulated 21.5 volt DC power to sensors, signal conditioners, data acquisition systems and high level logic equipment. Significant DRN features include: ¥ 4kV tested isolation, primary to output ¥ VDE-style patented shrouded double-bobbin design ¥ PET polyester bobbins, UL 94VO flammabil ...

  • Omega Engineering DRN-PS-750 - page 5

    2.1 Input Voltage Tolerances Exceeds IEC 38 range 2.2 Input / Output Isolation 4KV rms 60Hz 1 minute test 630V conductor spacing, IEC 348 Exceeds VDE551 / IEC 742 separation spacing Exceeds VDE106 protective separation Exceeds VDE 160 clearance distances Exceeds VDE160 creepage distances 2.3 Protective Classes IEC 529: IPÐ20 VDE 106 Part 1: Class ...

  • Omega Engineering DRN-PS-750 - page 6

    The DRN power supplies are heavy enough to cause damage and or injury if dropped during installation. Assure firm rail mounting before releasing grip on the unit. If a rail assembly is to be transported, then disconnection, dismounting and separate packing of the power supply is recommended. For units that must be shipped installed on the rail, add ...

  • Omega Engineering DRN-PS-750 - page 7

    T o change voltage jumpers: 1. Remove cover from case by carefully prying up two side tabs using a screwdriver . Remove two screws from bottom of case. Slide unit out of case. 2. Locate the main board assembly and position it in front of you the same way as shown in Figure 3.1 on the following page. 3. On the main board, locate the transformer jump ...

  • Omega Engineering DRN-PS-750 - page 8

    Figure 3.1 Ñ Main Board Power Jumpers MAIN BOARD T1 115VAC WIRING SHOWN WITH W1 W3 TRANSFORMER MOUNTING PLATE W2 115VAC JUMPER WIRING W1 W3 W2 230VAC JUMPER WIRING W2 W3 W1 I NST ALLA TION AND R EMOV AL 3 6 DRN-PS Ñ DIN Rail Power Supplies ...

  • Omega Engineering DRN-PS-750 - page 9

    Figure 3.2 Ñ 35mm "Top Hat" Installation: Hook in the module with the mounting rail guide on the top edge of the mounting rail and lower it to lock it into position. Removal: Release the spring catch with a screwdriver while raising the module to disengage it. installation removal I NST ALLA TION AND R EMOV AL 3 7 DRN-PS Ñ DIN Rail Powe ...

  • Omega Engineering DRN-PS-750 - page 10

    Figure 4.1 Ñ Front Panel Connection Labels shown without regulator cover AC Line AC Neutral Ground RETURN NO CONNECTION +21.5V IN AC N PWR +V N/C OUT DC I NPUT AND O UTPUT C ONNECTIONS 4 8 DRN-PS Ñ DIN Rail Power Supplies ...

  • Omega Engineering DRN-PS-750 - page 11

    5.1 PS Type Labeling DRNÐPSÐ750, where 750 equals mA rating. DRNÐPSÐ750 5.2 Size & Weight Height: 2.76" (70mm) Width: 2.95" (75mm) Depth: 5.95" (151mm) Weight: 2.0 lbs. (0.9 kg) 5.3 Mounting 35mm "top hat" DIN EN 50022 5.4 Temperature Ranges Operating Temperature Ranges -20 to 60 degrees C Storage Temperature Ranges ...

  • Omega Engineering DRN-PS-750 - page 12

    5.5 Input Range 115 or 230V, 49Ð61Hz DRNÐPSÐ750 ± 10% 5.6 Input Current Surge Protection 6kA/275V Varistor 5.7 Output Voltage 21.5V ± 2% - IR, where I = output current amperes and R = 0.3½ 5.8 Output Current DRNÐPSÐ750 0Ð750mA 5.9 Output Ripple Less than 10mV pp S PECIFICA TIONS 5 10 DRN-PS Ñ DIN Rail Power Supplies ...

  • Omega Engineering DRN-PS-750 - page 13

    5.10 Temperature Derating None below 50 degrees C DRNÐPSÐ750, 15mA per degree C above 50¡C 5.11 Power-on Indicator Front Panel red LED lamp 5.12 Short-circuit and overload protection DRNÐPSÐ750 foldback current limiting with automatic high temperature shutdown no fuses required 5.13 Wire Connections Screw down wire clamps, AWG 12 to 26 (ferrul ...

  • Omega Engineering DRN-PS-750 - page 14

    Figure 6.1 Ñ Derating Graph Figure 7.1 Ñ Block Diagram 49-61Hz 115/230vac INPUT: (+V) Ground AC Line AC Neutral V A R I S T O R L C F I L T E R B R I D G E ( ) 21.5V R E G U L A T O R  Return 75mA 50 DRN-PS-750 ¡ C Ambient 0 1000 800 600 400 200 60 45 35 25 15 5 -5 I max. D ERA TING G RAPH / B LOCK D IAGRAM 6/7 12 DRN-PS Ñ DIN Rail Power Sup ...

  • Omega Engineering DRN-PS-750 - page 15

    Figure 8.1 Ñ Dimensions SPACED AS SHOWN. POWER SUPPLY WITH [151.1] 5.95 2.76 2.95 3.15 TWO SCREWS FASTEN RAIL UNDER MAX [70.0] [75.0] [80.0] D IMENSIONS D RA WING 8 13 DRN-PS Ñ DIN Rail Power Supplies ...

  • Omega Engineering DRN-PS-750 - page 16

    S AFETY C ONSIDERA TIONS 14 DNR-PS Ñ DIN Rail Power Supplies Unpacking & Inspection Unpack the instrument and inspect for obvious shipping damage. Do not attempt to operate the unit if damage is found. This instrument is a panel mount device protected in accordance with Class I of EN 61010 (115/230 AC power connections). Installation of this i ...

  • Omega Engineering DRN-PS-750 - page 17

    WARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGAÕs customers receiv ...

  • Omega Engineering DRN-PS-750 - page 18

    Where Do I Find Everything I Need for Process Measurement and Control? OM EGAÉOf Course! TEMPERATURE M U Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies M U Wire: Thermocouple, RTD & Thermistor M U Calibrators & Ice Point References M U Recorders, Controllers & Process Monitors M U Infrared Pyrometers PRE ...

Fabbricante Omega Engineering Categoria Power Supply

I documenti che otteniamo dal fabbricante del dispositivoOmega Engineering DRN-PS-750 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Omega Engineering
- manuali per l’uso DRN-PS-750
- schede prodotto Omega Engineering
- opuscoli
- o etichette energetiche Omega Engineering DRN-PS-750
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Omega Engineering DRN-PS-750.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Omega Engineering DRN-PS-750, manuali di manutenzione, brevi manuali o manuali utente Omega Engineering DRN-PS-750. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Omega Engineering DRN-PS-750.

Manuale completo del dispositivo Omega Engineering DRN-PS-750, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Omega Engineering DRN-PS-750 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Omega Engineering DRN-PS-750.

Il manuale per l’uso completo Omega Engineering, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Omega Engineering DRN-PS-750 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Omega Engineering DRN-PS-750, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Omega Engineering DRN-PS-750 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Omega Engineering DRN-PS-750 - che ci dovrebbe aiutare nei primi passi durante l'uso Omega Engineering DRN-PS-750
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Omega Engineering DRN-PS-750
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Omega Engineering DRN-PS-750 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Omega Engineering DRN-PS-750?

Utilizza il modulo sottostante

Se non hai risolto il problema con Omega Engineering DRN-PS-750 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Omega Engineering DRN-PS-750 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)