Manuale per l’uso Athena Technologies A88028

16 pagine 1.29 mb
Scarica

Vai alla pagina of 16

Summary
  • Athena Technologies A88028 - page 1

    1 SERVICE AND INSTALLATION Installation & Servicing Instructions PLEASE LEAVE THESE INSTRUCTIONS WITH THE USER FOR USE WITH NATURAL GAS ONLY G .C. No. 32 170 19 ÿ Product Code No. A88028 The Data Badge and Serial Number are located on the left hand side of the back panel. Cat I G20 at 20mbar in GB and IE 2H A THEN A LF A THEN A LF ...

  • Athena Technologies A88028 - page 2

    2 CONTENTS LAYOUT INTRODUCTION AND GENERAL INST ALLATION REQUIREMENTS 1.0 TECHNICAL DA TA 2.0 CONDITIONS OF INSTALLA TION 2.1 SITING GENERAL 2.2 FLUES AND CHIMNEYS 2.2.1 Brick Chimney, 178mm diameter (7 inch) S tone or Lined Flue and 125mm diameter (5 inch) Flue 2.2.2 Pre-Cast Flue 2.2.3 Metal Fluebox 125mm diameter (5 inch) Flues 2.3 SHELF HEIGHT ...

  • Athena Technologies A88028 - page 3

    3 INTRODUCTION 1.0 TECHNICAL DATA GENERAL INST ALLATION REQUIREMENTS NO COMPONENT OF THIS FIRE IS MANUFACTURED FROM ASBESTOS OR ASBESTOS RELA TED PRODUCTS. The A THENA L.F . is an open fronted inset live coal effect gas fire specially designed for Pre-Cast Flue application and is also suitable for use with Brick Chimneys, twin walled or insulated M ...

  • Athena Technologies A88028 - page 4

    4 2.1 SITING GENERAL This fire is suitable for hearth mounting only on a non-combustible hearth at least 13mm thick and measuring at least 630mm wide by 330mm deep. Its top surface should preferably be 50mm above the floor level in order to discourage the placing of carpets or rugs over it. It MUST NOT be fitted directly on a combustible wall. The ...

  • Athena Technologies A88028 - page 5

    2.2.2 PRE-CAST FLUE OF MINIMUM SIZE (Fig. 2) This fire can be installed into a properly constructed pre-cast flue conforming to B.S. 1289 : 1975 or B.S. 1289 : Part 1 : 1986 or B.S. 1289 : Part 2 : 1989 of at least 3 metres effective height and having flueways of at least 198mm by 67mm or equivalent cross-sectional area with no dimension less than ...

  • Athena Technologies A88028 - page 6

    6 2.2.3 METAL FLUE BOX/125mm DIAMETER FLUES (Figs. 3A and 3B) This fire may be installed in a double walled or insulated metal box built to the requirements of B.S. 715 e.g. Selkirk, Product Code Number 0404805, using our fixing kit G .C. Number 159 634 ÿ Number 992137. The box must be lagged as detailed in Fig. 3B and mounted on a non-combustible ...

  • Athena Technologies A88028 - page 7

    2.3 SHELF HEIGHT AND SIDE CLEARANCES The fire may be fitted beneath a shelf. 2.3.1 COMBUSTIBLE SHELF The underside of a combustible shelf not more than 150mm deep must be at least 923mm from the hearth which gives a clearance of 237mm above the fire. For deeper shelves, add 13mm shelf height for every 25mm increase in depth. For every 25mm decrease ...

  • Athena Technologies A88028 - page 8

    8 3.3 METHOD OF INSTALLA TION There are two methods for securing the fire to the wall which are: (a) Fixing by tension cable. (b) Screwing the fire directly to the wall. It is recommended, where drilling holes in the front face of the fireplace surround is unacceptable or otherwise risky e.g. a marble surround, that fixing by tension cable is emplo ...

  • Athena Technologies A88028 - page 9

    Fig. 6 73mm 115mm 3.3.2 FIXING DIRECTLY TO SURROUND FACE Mark the four positions of the fixing holes on the front face of the fireplace surround using the fire as a template. Drill 6mm holes and plug the holes with the wall plugs supplied. Insert the fire into the opening in the fireplace until the seal on the back of the fire is compressed against ...

  • Athena Technologies A88028 - page 10

    10 4.0 COMMISSIONING 4.1 INSTALL FUEL EFFECT COMPONENTS The fuel effect components comprise: (a) Rear Coal (b) Two Side Cheeks (c) Coal Bed (d) Nine Loose Coals The Coal Bed and the loose coals are illustrated in Fig. 7A. The fire is supplied with the rear coal and side cheeks already fitted as illustrated in Fig. 7B. Unpack the pack containing the ...

  • Athena Technologies A88028 - page 11

    11 4.2 CHECK GAS PRESSURE Remove the pressure test point screw located on the injector feed pipe just left of centre on the fire. Connect a pressure gauge, slide the control knob down to the PILOT/IGNITION position. Keep the knob depressed after the pilot has lit to activate the FSD and then slide the knob to the HIGH position. Check that the gas p ...

  • Athena Technologies A88028 - page 12

    12 4.4 TEST FOR SPILLAGE A test for spillage must be made before the installed fire is left with the user . This is carried out in the following manner. Light the fire and leave at HIGH rate. Close all the doors and windows in the room and after the fire has been alight for five minutes insert a lighted smoke match in line with the bottom edge of t ...

  • Athena Technologies A88028 - page 13

    13 6.0 SERVICING INSTRUCTIONS IMPORTANT NOTES 1. Turn off the gas supply to the fire before starting any servicing. 2. Always test for gas soundness after servicing or exchanging any component. 3. Remove the fire from the surround and inspect the catchment space for build up of debris on every service visit. 4. Check the fire for clearance of produ ...

  • Athena Technologies A88028 - page 14

    14 6.4 PILOT ASSEMBLY The pilot is an atmosphere sensing device and must be replaced as a complete unit. Repair must not be undertaken. NOTE: If the fire keeps going out or exhibits signs of nuisance shut off, check the operation of the pilot as follows:- (a) Inspect the pilot flame, if suspect check the gas supply. Clear blockage if necessary . If ...

  • Athena Technologies A88028 - page 15

    15 The following are possible fault conditions. Check the items mentioned and repair or replace parts as necessary. The list is not exhaustive but a fair outline of possible faults. 1. No Spark (a) Check spark by manually operating the micro switch. (b) The battery may be exhausted. Check and replace if necessary. (c) Check the spark gap and electr ...

  • Athena Technologies A88028 - page 16

    ÿ PAR T NUMBER DESCRIPTION 822309 Gas Valve / FSD Assembly 990274 Control Knob 822308 Pilot Assembly (Natural Gas) 993911 Spark Lead 822238 Ignition Unit 992232 Rear Coal 992234 Coal Bed 992169 Loose Coals (9 off) 992178 Left Side Cheek 992179 Right Side Cheek 16 8.0 SHORT LIST PARTS 989882 Issue 2 ROBINSON WILLEY LIMITED Mill Lane, Old Swan, Live ...

Fabbricante Athena Technologies Categoria Fire Pit

I documenti che otteniamo dal fabbricante del dispositivoAthena Technologies A88028 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Athena Technologies
- manuali per l’uso A88028
- schede prodotto Athena Technologies
- opuscoli
- o etichette energetiche Athena Technologies A88028
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Athena Technologies A88028.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Athena Technologies A88028, manuali di manutenzione, brevi manuali o manuali utente Athena Technologies A88028. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Athena Technologies A88028.

Manuale completo del dispositivo Athena Technologies A88028, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Athena Technologies A88028 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Athena Technologies A88028.

Il manuale per l’uso completo Athena Technologies, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Athena Technologies A88028 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Athena Technologies A88028, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Athena Technologies A88028 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Athena Technologies A88028 - che ci dovrebbe aiutare nei primi passi durante l'uso Athena Technologies A88028
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Athena Technologies A88028
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Athena Technologies A88028 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Athena Technologies A88028?

Utilizza il modulo sottostante

Se non hai risolto il problema con Athena Technologies A88028 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Athena Technologies A88028 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)