    USER GUIDE AND SPECIFICATIONS NI USB-9234 4-Channel, ±5 V , 24-Bit Softwar e-Selectable IEPE and AC/DC Analog Input Module This user guide describes how to use the National Instruments USB-9234 and includes device specifications and co nnector assignments. Introduction The NI USB-9234 consists of two compo nents: an NI 9234 mo dule and an NI USB-9 ...

  • National Instruments NI USB-9234 - page 2

    NI USB-9234 U ser Guide and Specifications 2 ni.com Dimensions Figure 2 shows the NI USB-9234 device dim ensions. Figure 2. NI USB-9234 Device in Millimeters (Inches) Safety Guidelines Operate the NI USB-9234 only as described in this user guide. Note Although the NI 9234 module may have more stringent certification standards than the NI USB-9234, ...

  • National Instruments NI USB-9234 - page 3

    © National Instruments Corporation 3 NI USB-9234 User Guid e and Specifications Safety Guidelines for Hazardous Vo ltages If hazardous voltages are connected to the module, take the following precautions. A hazardous vo ltage is a voltage greater than 42.4 V pk or 60 VDC to earth ground. Caution Ensure that hazardous v oltage wiring is performed o ...

  • National Instruments NI USB-9234 - page 4

    NI USB-9234 U ser Guide and Specifications 4 ni.com LabVIEW If you are a new user, use the Getting Started with LabVIEW manual to familiarize yourself with the LabVIEW graphical programming environment and the basic LabVIEW features you use to build data acquisition and instrum ent control applications. Op en the Getting Started with LabVIEW manual ...

  • National Instruments NI USB-9234 - page 5

    © National Instruments Corporation 5 NI USB-9234 User Guid e and Specifications Measurement Studio If you program your NI-D A Qmx-su pported device in Measurement Studio using V isual C++, V isual C#, or V isu al Basic .NET , you can interactively create channels and tasks by launching the D A Q Assistant from MAX or from within V isual Studio .NE ...

  • National Instruments NI USB-9234 - page 6

    NI USB-9234 U ser Guide and Specifications 6 ni.com .NET Languages without NI Application Software W ith the Microsoft .NET Framework v ersion 1.1 or later , you can use NI-D A Qmx to create applications us ing V isual C# and V isual Basic .NET without Measurement Studi o. Y ou need Microsoft V isual Studio .NET 2003 or Microsoft V isual Studio 200 ...

  • National Instruments NI USB-9234 - page 7

    © National Instruments Corporation 7 NI USB-9234 User Guid e and Specifications Installing the Software Software support for the NI USB-92 34 for Windows Vist a/XP/2000 is provided by NI-DAQmx. The DAQ Getting S tarted Guide , which you can download at ni.com/manuals , offers NI-DAQmx users st ep-by-step instructions for installing software and ha ...

  • National Instruments NI USB-9234 - page 8

    NI USB-9234 U ser Guide and Specifications 8 ni.com 3. Align the I/O module with the carrier , as sho wn in Figure 3. Figure 3. Module Installation 4. Squeeze the latches and insert the NI 9234 module into the NI USB-9162 carrier . 5. Press f irmly on the connecto r side of the NI 9234 module until the latches lock the module into place, as sho wn ...

  • National Instruments NI USB-9234 - page 9

    © National Instruments Corporation 9 NI USB-9234 User Guid e and Specifications Mounting the NI USB-9234 Threaded inserts are located in the NI USB-9234 for mounting it to a panel. Refer to Figure 5 for the module dimensio ns. Figure 5. Module Dimensions Connecting the NI USB-9234 to a Computer Plug one end of the USB cable into the NI USB-9234 an ...

  • National Instruments NI USB-9234 - page 10

    NI USB-9234 U ser Guide and Specifications 10 ni.com LED Indicator The NI USB-9234 device has a green LED next to the USB connector. The LED indicator indicates device stat us, as listed in Table 1. When the device is connected to a USB port, t he LED blinks steadily to indicate that the device is initialized and is r eceiving power from the connec ...

  • National Instruments NI USB-9234 - page 11

    © National Instruments Corporation 11 NI USB-9234 User Guid e and Specifications Wiring the NI USB-9234 The NI USB-9234 has four BNC connectors that provide connection s to four simultaneousl y sampled analog input channels. Each channel has a BNC connector to which you can conn ect a signal source. You can also enable excitation current on a per- ...

  • National Instruments NI USB-9234 - page 12

    NI USB-9234 U ser Guide and Specifications 12 ni.com Connecting Signal Sources to the NI USB-9234 You can connect ground-referenced or floating signal sensors to the NI USB-9234. To avoid picking up ground noi se, use a floating connection. To fu rther minimi ze ground noise, prevent th e metal shells of the BNC connectors from touching each ot her ...

  • National Instruments NI USB-9234 - page 13

    © National Instruments Corporation 13 NI USB-9234 User Guid e and Specifications NI USB-9234 Circuitr y The NI USB-9234 analog input channels are referenced to chassis groun d through a 50 Ω resistor. To minimize ground noise, m ake sure that the chassis ground is connected to earth ground. Each channel is protect ed from overvoltages. You can co ...

  • National Instruments NI USB-9234 - page 14

    NI USB-9234 U ser Guide and Specifications 14 ni.com The NI USB-9234 also has TEDS circuitry . F or more information about TEDS, go to ni.com/info and enter rdteds . Understanding NI USB-9234 Filtering The NI USB-9234 uses a combination of analog and digit al filtering to provide an accurate representation of i n-band signal s while rejecting out-o ...

  • National Instruments NI USB-9234 - page 15

    © National Instruments Corporation 15 NI USB-9234 User Guid e and Specifications Stopband The filter significantly attenuates all si gnals above the stopband frequency . The primary goal of the filter is to prevent aliasing. Th erefore, the stopband frequency scales precisely with the data rate. The sto pband rejection is the minimum amou nt of at ...

  • National Instruments NI USB-9234 - page 16

    NI USB-9234 U ser Guide and Specifications 16 ni.com Specifications The following specifications are ty pical for the range 0 to 60 °C unless otherwise noted. Input Characteristics Number of channels .............. ...... ............4 analog input channels ADC resolution ....... ................. ...............24 bits Type of ADC ............... ...

  • National Instruments NI USB-9234 - page 17

    © National Instruments Corporation 17 NI USB-9234 User Guid e and Specifications AC cutoff frequency response Input range .. ................. ................. ......... ±5 V AC voltage full-scale range Minimum ..... ................. .................. ±5 V pk Typical ............ .................... ............ ±5.1 V pk Maximum .......... ...

  • National Instruments NI USB-9234 - page 18

    NI USB-9234 U ser Guide and Specifications 18 ni.com Overvoltage protection (with respect to chassis ground) For a signal source connected to AI+ and AI– ............ ................ ....±30 V For a low-impedance sou rce connected to AI+ and AI– ...............– 6 to 30 V Input delay ....................... ................. ......3.2 ms + ...

  • National Instruments NI USB-9234 - page 19

    © National Instruments Corporation 19 NI USB-9234 User Guid e and Specifications Phase nonlinearity ( f s = 51.2 kS/s) ...... ................. ......... ±0.45° max Stopband Frequency................. ................ ....... 0.55 · f s Rejection .................... ................. .... 100 dB Alias-free bandwidth .................. ........ ...

  • National Instruments NI USB-9234 - page 20

    NI USB-9234 U ser Guide and Specifications 20 ni.com Power Requirements Current consumption from USB ............ . 500 mA, max Suspend mode ................ ................. . 2.5 mA, max Bus Interface USB specifi cation ......... .................... ......USB 2.0 Hi-Speed Physical Characteristics Dimensions ......................... ........... ...

  • National Instruments NI USB-9234 - page 21

    © National Instruments Corporation 21 NI USB-9234 User Guid e and Specifications Safety Standards This product is designed to meet the requirements of the follow ing standards of safety for electrical e quipment for measurement, control, and laboratory use: • IEC 61010-1, EN-61010-1 • UL 61010-1, CSA 61010-1 Note For UL and other safety certif ...

  • National Instruments NI USB-9234 - page 22

    NI USB-9234 U ser Guide and Specifications 22 ni.com CE Compliance This product meets the essential re quirements of applicable European Directives, as amended fo r CE marking, as follows: • 2006/95/EC; Lo w-V oltage Directiv e (safety) • 2004/108/EC; Elect romagnetic Compatibility Directiv e (EMC) Note Refer to the Declaration of Conformity (D ...

  • National Instruments NI USB-9234 - page 23

    National Instruments, NI, ni.com, and LabVIEW are tradem arks of National Instruments Corporation. Refer to t he Terms of Use section on ni.com/legal for m ore inform ation about Natio nal Instruments trademarks. Other product and compan y names mentioned herein are trademarks or trade names of their respective companie s. For patents coveri ng Nat ...

Fabbricante National Instruments Categoria Network Card

I documenti che otteniamo dal fabbricante del dispositivoNational Instruments NI USB-9234 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici National Instruments
- manuali per l’uso NI USB-9234
- schede prodotto National Instruments
- opuscoli
- o etichette energetiche National Instruments NI USB-9234
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso National Instruments NI USB-9234.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione National Instruments NI USB-9234, manuali di manutenzione, brevi manuali o manuali utente National Instruments NI USB-9234. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto National Instruments NI USB-9234.

Manuale completo del dispositivo National Instruments NI USB-9234, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare National Instruments NI USB-9234 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti National Instruments NI USB-9234.

Il manuale per l’uso completo National Instruments, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale National Instruments NI USB-9234 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice National Instruments NI USB-9234, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per National Instruments NI USB-9234 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo National Instruments NI USB-9234 - che ci dovrebbe aiutare nei primi passi durante l'uso National Instruments NI USB-9234
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del National Instruments NI USB-9234
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio National Instruments NI USB-9234 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su National Instruments NI USB-9234?

Utilizza il modulo sottostante

Se non hai risolto il problema con National Instruments NI USB-9234 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con National Instruments NI USB-9234 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)