Manuale per l’uso Omega FTB600B

26 pagine 0.41 mb
Scarica

Vai alla pagina of 26

Summary
  • Omega FTB600B - page 1

    omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info FTB600B Series Ultra-Low Flow Sensors Shop online at U ser ’ s Guide ...

  • Omega FTB600B - page 2

    OMEGAnet ® On-Line Service Internet e-mail omega.com info@omega.com It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certi ...

  • Omega FTB600B - page 3

    TABLE OF CONTENTS FTB600B Series Ultra-Low Flow Sensors i Section Page Section 1 Introduction ...................................................................... 1 A. General Description .................................................... 1 B. Principle of Operation ................................................. 1 C. Material Characteristics ...

  • Omega FTB600B - page 4

    ii FTB600B Series Ultra-Low Flow Sensors NOTES: ...

  • Omega FTB600B - page 5

    1 1 FTB600B Series Installation IMPORTANT: READ INSTRUCTIONS THOROUGHLY BEFORE INSTALLING FLOW METER Section 1 - Introduction A. General Description The FTB600B Series is an axial paddle wheel turbine type flow meter based on the pelton wheel principle. This unique patented design makes the FTB600B Series a very accurate, repeatable, linear device. ...

  • Omega FTB600B - page 6

    2 FTB600B Series Installation 1 C. Material Characteristics of PVDF (Polyvinylidene Fluoride) 1. Material of construction Trade name - Kynar All wetted parts of the FTB600B Series are PVDF, excluding the O-ring. Wetted parts include any part of the meter that will or could come in contact with the fluid. List of wetted parts: 1. Barbed fittings 5. ...

  • Omega FTB600B - page 7

    3 2 FTB600B Series Operating Parameters Section 2. - Operating Parameters A. Temperature Since the FTB600B Series has printed circuit boards molded into the body of the meter it is strongly recommended that 180°F not be exceeded. Exceeding 180°F can cause irreparable damage to the circuit boards. B. Flow Ranges The FTB600B Series is available in ...

  • Omega FTB600B - page 8

    4 FTB600B Series Operation Parameters 2 ...

  • Omega FTB600B - page 9

    5 FTB600B Series Operating Parameters 2 C. Recommended Viscosity Range 1-5 cSt (w/o correction) The effects of changing viscosity on the FTB600B Series are the same as any other turbine flow meter. It is important to remember that a turbine meter is a viscosity dependent device, where as the viscosity increases the linearity of the flow meter will ...

  • Omega FTB600B - page 10

    6 3 FTB600B Series Silicone Treatment Section 3 - Silicone Treatment Silicone treatment is standard for all types of the FTB600B Series series electronics. ...

  • Omega FTB600B - page 11

    7 4 FTB600B Series Infrared Sensors Section 4 - Infrared Sensor A. Supply Voltage 24 Vdc. Do not exceed 24 Vdc. Doing so can cause overheating and eventual failure of all PC boards. Printed circuit boards are non- repairable. B. Frequency Output 1. Square wave pulse, unscaled (See Figure 4-1) 2. Output impedance 75 ohms 3. Directly proportional to ...

  • Omega FTB600B - page 12

    8 FTB600B Series Infrared Sensors 4 C. Frequency Ranges for (non-cartridge models) pulses/l Model Frequency (Hz) K-Factor FTB601B 60 to 1200 36,000 FTB602B 40 to 1200 8,000 FTB603B 27 to 800 3,200 FTB604B 20 to 600 1,200 FTB605B 18.75 to 562 450 FTB606B 15 to 450 225 D. Cable Requirements 1. 20 to 22 AWG (American Wire Gauge) 2. 4 conductor-shielde ...

  • Omega FTB600B - page 13

    9 FTB600B Series Infrared Sensors 4 Figure 4-1. Output Frequency Waveforms ...

  • Omega FTB600B - page 14

    10 5 FTB600B Series Installation Section 5 - Installing the FTB600B Series in the fluid line. A. Make sure the fluid is compatible with PVDF (polyvinylidene fluoride) and meets viscosity, pressure and temperature parameters of the FTB600B Series. The fluid must also meet filtration requirements as listed in 3D. B. Install the FTB600B series in the ...

  • Omega FTB600B - page 15

    11 FTB600B Series Installation 5 Figure 5-1. Supply Voltage and Signal Output Connections ...

  • Omega FTB600B - page 16

    12 FTB600B Series Installation 5 Table 5-1. Piping Table ...

  • Omega FTB600B - page 17

    13 FTB600B Series Installation 5 Table 5-1. Piping Table Con't. ...

  • Omega FTB600B - page 18

    14 6 FTB600B Series Specifications Section 6 - Specifications Accuracy: ±3% of reading Repeatability: ±0.1% of reading Linearity: ±1% of reading Viscosity Range: 1 to 15 centistokes Working Pressure: 150 PSIG at 175°F Wetted Materials: PVDF Power Supply: 5 to 18 Vdc, 6 to 33 mA Output Signal : Unscaled square wave Pressure Drop: See Section 7 ...

  • Omega FTB600B - page 19

    15 7 FTB600B Series Pressure Drop Curves Section 7 - Pressure Drop Curves Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB601 50 0.5 0 1.0 Liters/minute kP a 1.5 2.0 45 40 35 30 25 20 15 10 5 0 ...

  • Omega FTB600B - page 20

    16 FTB600B Series Pressure Drop Curves 7 Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB602 250 2.0 0 4.0 Liters/minute kP a 8 .0 6.0 10.0 200 150 100 50 0 ...

  • Omega FTB600B - page 21

    17 FTB600B Series Pressure Drop Curves 7 Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB603 200 51 0 1 5 0 Liters/minute kP a 160 1 8 0 140 100 8 0 60 40 20 120 0 ...

  • Omega FTB600B - page 22

    18 FTB600B Series Pressure Drop Curves 7 Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB604 200 10 20 30 0 Liters/minute kP a 160 1 8 0 140 100 8 0 60 40 20 120 0 ...

  • Omega FTB600B - page 23

    19 FTB600B Series Pressure Drop Curves 7 Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB605A 160 140 120 100 8 0 60 40 20 10 20 30 40 50 60 0 Liters/minute kP a 0 ...

  • Omega FTB600B - page 24

    20 FTB600B Series Pressure Drop Curves 7 Pressure Drop FTB600B Series Liquid Turbine - Flowmeter FTB606A 1 8 0 160 140 120 100 8 0 60 40 20 10 20 30 40 50 60 70 8 09 0 0 Liters/minute kP a 0 ...

  • Omega FTB600B - page 25

    FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: 1. Purchase Order number under which the product was PURCHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product. FOR NON-WARRANTY REPAIRS, consult OMEGA for current repa ...

  • Omega FTB600B - page 26

    TEMPERATURE 䡺 ⻬ Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies 䡺 ⻬ Wire: Thermocouple, RTD & Thermistor 䡺 ⻬ Calibrators & Ice Point References 䡺 ⻬ Recorders, Controllers & Process Monitors 䡺 ⻬ Infrared Pyrometers PRESSURE, STRAIN AND FORCE 䡺 ⻬ Transducers & Strain Gages 䡺 ⻬ ...

Fabbricante Omega Categoria Stud Sensor

I documenti che otteniamo dal fabbricante del dispositivoOmega FTB600B possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Omega
- manuali per l’uso FTB600B
- schede prodotto Omega
- opuscoli
- o etichette energetiche Omega FTB600B
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Omega FTB600B.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Omega FTB600B, manuali di manutenzione, brevi manuali o manuali utente Omega FTB600B. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Omega FTB600B.

Manuali per l’uso simili

Manuale completo del dispositivo Omega FTB600B, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Omega FTB600B dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Omega FTB600B.

Il manuale per l’uso completo Omega, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Omega FTB600B - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Omega FTB600B, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Omega FTB600B che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Omega FTB600B - che ci dovrebbe aiutare nei primi passi durante l'uso Omega FTB600B
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Omega FTB600B
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Omega FTB600B in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Omega FTB600B?

Utilizza il modulo sottostante

Se non hai risolto il problema con Omega FTB600B con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Omega FTB600B è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)