    © 1998–2003 National Instruments Corp. All rights reserved. LabVIEW™, National Instru ments™, NI™, ni.com™, NI-DAQ ™, and SCXI™ are t rademarks of National Instrument s Corporation. Product and com pany names mentioned herein are trademarks or trade names of their respective companies. For patent s covering National Instruments produ ...

  • National Instruments SCXI-1321 - page 2

    SCXI-1321 T erminal Block Installation Guide 2 ni.com italic Italic text denotes variables, emphasis, a cross reference, or an int roduction to a key concept. This font also denote s te xt that is a placeholder for a word or v alue that you must supply . monospace T ext in this font denotes text or ch aracters that you should enter from the keyboar ...

  • National Instruments SCXI-1321 - page 3

    © National Instruments Cor poration 3 SCXI-1321 T erminal Block Installa tion Guide Connecting the Signals Note Refer to the Read Me First: Safety and Radio-Frequency Interference document before removing equipment covers, or connecting or disconnecting any signal wires. To connect the signal to the terminal block, complete the following steps, re ...

  • National Instruments SCXI-1321 - page 4

    SCXI-1321 T erminal Block Installation Guide 4 ni.com Figure 1. SCXI-132 1 Parts Locator Diagram 1 Strain-Relief Bar 2 Strain-Relief Screws 3 Safety-Ground Lug 4 Mating Connector 5 Thumbscrew 6 Top-Cover Screws 7 Top Cover Back Vie w F ront View 2 1 3 4 5 7 6 ...

  • National Instruments SCXI-1321 - page 5

    © National Instruments Cor poration 5 SCXI-1321 T erminal Block Installa tion Guide Figure 2. SCXI-1321 Circuit Parts Locator Diagram Installing the T erminal Block To connect the terminal block to the SCXI mo dule front connector, complete the follow ing steps: 1. Connect the module front connector to its connector on the terminal block. 2. Make ...

  • National Instruments SCXI-1321 - page 6

    SCXI-1321 T erminal Block Installation Guide 6 ni.com Note T o minimize the temperature gradient inside the termin al block, move the SCXI chassis aw ay from any extr eme temperature dif ferential. Specifications All specifications are typical at 25 °C unless otherwise specified . Electrical Cold-junction sensor Accuracy 1 ........... ............ ...

  • National Instruments SCXI-1321 - page 7

    © National Instruments Cor poration 7 SCXI-1321 T erminal Block Installa tion Guide Environmental Operating temperature........................ .... 0 to 50 °C Storage temperature ............. ................. . –20 to 70 °C Humidity ............. .............. .............. ....... 10 to 90% RH, noncondensing Maximum altitude ............ ...

  • National Instruments SCXI-1321 - page 8

    SCXI-1321 T erminal Block Installation Guide 8 ni.com Note Refer to the Declaration of Conformity (DoC) for this product fo r any additional regulatory compliance in formation. T o obtain th e DoC for this p roduct, click Declarations of Conformity Information at ni.com/hardref.nsf/ . Performed or Supported Signal Conditioning This section provides ...

  • National Instruments SCXI-1321 - page 9

    © National Instruments Cor poration 9 SCXI-1321 T erminal Block Installa tion Guide The factory default v alue of all the nulling resistors on the terminal blo ck is 39 k Ω . Note These resistors are socketed for easy re placement. These sockets best f it a 1/4 W resistor lead size. T o determ ine the nulling range, use the f ollowing formula wh ...

  • National Instruments SCXI-1321 - page 10

    SCXI-1321 T erminal Block Installation Guide 10 ni.com Assuming a strain-gauge range with a gauge factor of GF = 2 and a quarter-bridge conf iguration, this range corresponds to ±1,498 µε , as given by the strain formula for a quarter-bridge strain-gauge configuration: where Figure 3. Quarter-Bridge Nulling Circuit ε 4 V r – GF 12 V r + () -- ...

  • National Instruments SCXI-1321 - page 11

    © National Instruments Cor poration 11 SCXI-1321 T erminal Bloc k Installa tion Guide Figure 4. Half-Bridge Nulling Circuit CH+ CH+ CH– EX+ EX– + – + – R 1 R 2 4.5 k Ω 4.5 k Ω R SCAL 301 k Ω R Tr i m 10 k Ω R Null 39.1 k Ω (Screw Adjusts P otentiometer) R L R L R L R 4 (gauge) EX+ CH+ CH+ CH– EX+ EX– R Tr i m SCXI-1121 SCXI-1 ...

  • National Instruments SCXI-1321 - page 12

    SCXI-1321 T erminal Block Installation Guide 12 ni.com Figure 5. Full-Bridge Nulling Cir cuit Shunt Calibration Shunt calibration prov ides a method of adjusti ng for gain error to improve accuracy. The shunt-calibration circui try configuration places a shunting resistor in parallel with the resis tive element connected between EX+ and CH+ (elemen ...

  • National Instruments SCXI-1321 - page 13

    © National Instruments Cor poration 13 SCXI-1321 T erminal Bloc k Installa tion Guide z is the module slot of the SCXI-1121 w is the channel o f the module that you want to engage th e shunt and take measurements For e xample, if you want to measure th e volta ge at channel 0 with the shunt resistor enabled, use the SCXI channel string ob0 ! sc1 ! ...

  • National Instruments SCXI-1321 - page 14

    SCXI-1321 T erminal Block Installation Guide 14 ni.com gauge with a gauge factor of GF = 2, V exc = 3.3 V , and R = 120 Ω prod uces the following: V change = 0.3321 mV Replacing the strained voltage by V change in the quarter-bridge strain equation produces an equ i valent 199 µε of change. Refer to the NI-DAQ User Manual for more informat ion ...

  • National Instruments SCXI-1321 - page 15

    © National Instruments Cor poration 15 SCXI-1321 T erminal Bloc k Installa tion Guide Y ou can read a temperature at the begi nning of the test and use that value with the data that follows. Using this method assumes that there are no temperature v ariations during the measurement period. If there are temperature variations, the measure m ents can ...

  • National Instruments SCXI-1321 - page 16

    321924C-01 J an03 *321924C-01* W3 Nulling circuit of Channel 2 is enabled (factory default setting) Nulling circuit of Channel 2 is disabled W4 Nulling circuit of Channel 3 is enabled (factory default setting) Nulling circuit of Channel 3 is disabled Table 4. Jumper Settings of the Nu lling Circuits (Continued) Jum p e r Pos i t i o n Description D ...

メーカー National Instruments カテゴリー Switch

National Instruments SCXI-1321のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- SCXI-1321の取扱説明書
- National Instrumentsの製品カード
- パンフレット
- またはNational Instruments SCXI-1321の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、National Instruments SCXI-1321の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、National Instruments SCXI-1321の取り付け説明書、サービスマニュアル、簡易説明書、またはNational Instruments SCXI-1321のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、National Instruments SCXI-1321の製品を使用するにあたって最も人気のある説明書を閲覧できます。

National Instruments SCXI-1321デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがNational Instruments SCXI-1321を使用するのを助ける技術的文書のことです。説明書は通常、全てのNational Instruments SCXI-1321ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

National Instrumentsの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. National Instruments SCXI-1321の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははNational Instruments SCXI-1321の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。National Instruments SCXI-1321に関してこのドキュメントで見つけることができる全てのヒントの目次
3. National Instruments SCXI-1321デバイスの基本機能を使うにあたってのヒント。 National Instruments SCXI-1321のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。National Instruments SCXI-1321に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるNational Instruments SCXI-1321のメーカー/サービスへの連絡先に関する情報。

National Instruments SCXI-1321についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもNational Instruments SCXI-1321の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがNational Instruments SCXI-1321で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)