    INST ALLA TION- AND USER INSTRUCTIONS HOT WATER STORAGE HEATERS HIGH TEMPERATURE UNITED KINGDOM / IRELAND MODELS EQB 115 G EQB 155 G EQB 200 G ...

  • A.O. Smith EQB 200 G - page 2

    2 Warning: because of the high temperature setting this appliance is not suited for domestic use. Read these installation instructions first before installing the appliance. Carefully read the user instructions before igniting the appliance. Failure to follow these instructions may lead to risk of explosion and/or fire and could cause material dama ...

  • A.O. Smith EQB 200 G - page 3

    3 CONTENTS PAGE 1. General . ............................................................................................................ 4 1.1 Description of the appliance ............................................................................... 4 1.2 Technical safety equipment ................................................................ ...

  • A.O. Smith EQB 200 G - page 4

    4 1. GENERAL 1.1 Description of the appliance Construction of the water heater is in accordance with the European standard for gas heated water storage heaters for sanitary application (EN 89). The appliance thus meets the European Directory for Gas Appliances and is therefore entitled to carry the CE- marking. It is an open flued appliance without ...

  • A.O. Smith EQB 200 G - page 5

    5 Figure 1 - Cross-section of the heater 1) Draught diverter 2) Hot water outlet 3) Insulation 4) Flue tube 5) Glass lined tank 6) Gas control valve 7) Cold-water inlet 8) T&P valve connection 9) Outer casting 10) Flue baffle 11) Sacrificial anode 12) Drain valve 13) Atmospheric burner 14) Pilot light burner with thermocouple AOS 0478 ...

  • A.O. Smith EQB 200 G - page 6

    6 1.2 Technical safety equipment 1.2.1 Gas control valve The water heater has been fitted with a gas control block consisting of a thermo-electrical pilot flame safeguard, pilot flame pressure regulator, burner pressure regulator, a control thermostat (adjustable between 40°C and 80°C) and a safety thermostat (90°C). This gas control block with ...

  • A.O. Smith EQB 200 G - page 7

    7 Figure 2 - Gas control block with T.R.S. 1) T.R.S. thermostat 2) Sensor combustion products dicharge safety device 3) Thermocouple with built-in interrupter 4) Thermocouple 5) Gas control block 6) Reset button 7) Pilot burner 8) Temperature regulator knob AOS 0479 ...

  • A.O. Smith EQB 200 G - page 8

    8 1.3 Technical description 1.3.1 Dimensions These water heaters are only suitable for a flue tube with minimal the announced diameter (dimension G). Dimensions EQB 115 EQB 155 EQB 200 A 1280 1370 1670 B 1120 1210 1540 D 465 515 515 F 545 595 605 G 80 80 100 K 325 325 380 L 270 295 395 M 1180 1270 1590 N 1180 1270 1590 R 230 230 255 S 945 1030 1380 ...

  • A.O. Smith EQB 200 G - page 9

    9 Figure 3 - Dimensions AOS 0481 ...

  • A.O. Smith EQB 200 G - page 10

    10 GENERAL Storage capacity litres 1 09 144 181 Water connections ** - 3 / 4 " - 14 NPT 3 / 4 " - 14 NPT 3 / 4 " - 14 NPT Gas connection - ISO 7 / 1 Rp 1 / 2 ISO 7 / 1 Rp 1 / 2 ISO 7 / 1 Rp 1 / 2 Drain valve - 3 / 4 " - 14 NPT 3 / 4 " - 14 NPT 3 / 4 " - 14 NPT Anode - 3 / 4 " - 14 NPT 3 / 4 " - 14 NPT 3 / 4 & ...

  • A.O. Smith EQB 200 G - page 11

    11 2. FOR THE INSTALLER 2.1 Installation instructions This water heater must be fitted in a location which will permit the provision of an approved flue system and adequate ventilation. A service clearance of 15 cm at the sides and rear of the unit and 60 cm at the front of the unit should be allowed for ease of servicing. Adequate distance must be ...

  • A.O. Smith EQB 200 G - page 12

    12 1) Manual gas valve 2) Stop valve 3) Expansion vessel 4) T&P safety valve 5) Non return valve 6) Circulation pump 7) Drain valve Figure 4 - Connection diagram (unvented system) 8) Pressure limiting valve 9) Expansion valve A) Gas supply B) Hot water delivery C) Cold water inlet D) Hot water taps E) Return circulation See Figure 4. A.O. Smith ...

  • A.O. Smith EQB 200 G - page 13

    13 2.1.3 Gas connection The gas supply to this appliance must be installed in accordance with BS 6891 (1988). Fit the 1/2" gas supply cock supplied with this unit immediately before the gas control block. No heat or soldered joints should be applied in the vicinity of the gas control block, as they could cause damage to the control. All connec ...

  • A.O. Smith EQB 200 G - page 14

    14 2.2 Commissioning 2.2.1 Filling the water heater 1. Close the drain tap. 2. Open the cold water tap to the water heater and open all taps where hot water can be drained for de- aeration. The water heater is filled as soon as cold water flows from all taps. 3. Close all hot water taps. 2.2.2 Putting into operation 1. Check whether the water-heate ...

  • A.O. Smith EQB 200 G - page 15

    15 2.2.3 Removing and replacing the inner door (only for the EQB 115 and EQB 155 models, see Figure 7a). Procedure: 1. Place lip A through the recess on the right and subsequently slide it down behind the steel wall. See to it that both lower lips remain in front of the metal wall. 2. Press lip B through the recess on the left. 3. Subsequently slid ...

  • A.O. Smith EQB 200 G - page 16

    16 recommended to also close the cold water tap and to drain the appliance after cooling (open the drain tap; it is possible to connect a drain hose to the drain tap; open the nearest hot water drain point to prevent air locks). To be able to drain the appliance completely it should be disconnected and tilted slightly in the direction of the drain ...

  • A.O. Smith EQB 200 G - page 17

    17 2.6 Setting the nominal heat input The gas control has been factory preset to the water heater nominal heat input. A further check of the burner pressure should be carried out during the commissioning of the unit after installation. The following procedure should be followed. 1. Remove the protruding cover screw on the right side of the gas cont ...

  • A.O. Smith EQB 200 G - page 18

    18 G20 G30 G31 Inlet pressure mbar 20 30 37 Burner pressure mbar 10.5 30 37 Diameter main injector mm 3.50 1.95 1.95 Diameter pilot injector mm 2x0.27 0.22 0.22 G20 G30 G31 G20 G30 G31 Inlet pressure mbar 20 30 37 20 30 37 Burner pressure mbar 12.5 30 37 12.5 30 37 Diameter main injector mm 2.35 1.40 1.40 2.60 1.50 1.50 Diameter pilot injector mm 2 ...

  • A.O. Smith EQB 200 G - page 19

    19 2.8.1 Sacrificial anode The life cycle of the anode is determined by the quality and the quantity of the water flowing through the apparatus. It is therefore recommended that the anode be inspected and replaced if necessary at least once a year. 1. Close the stop cock in the cold water supply pipe, 2. Open the nearest hot water tap in order to a ...

  • A.O. Smith EQB 200 G - page 20

    20 2.8.2 Cleaning 1. Close the gas supply and demount the burner after it has cooled down, 2. Disconnect the burner, pilot pipe and thermo couple from the gas control block (see Figure 11), 3. Remove the complete burner assembly, 4. Clean the burner with a soft brush. 5. Check the pilot burner and clean it if so required, 6. Check the combustion ch ...

  • A.O. Smith EQB 200 G - page 21

    21 2.10 Fault finding In case of failure the following should be checked. 2.10.1 Safety thermostat All appliances have been fitted with a safety thermostat that shuts off the gas supply when the water temperature is too high. The safety thermostat remains activated until the water temperature drops below the safety temperature. The water heater mus ...

  • A.O. Smith EQB 200 G - page 22

    22 3. FOR THE USER 3.1 Commissioning Warning Installing and commissioning (for the first time) of this water heater should only be carried out by a qualified competent heating engineer. 3.1.1 Filling the water heater 1. Close the drain tap. 2. Open the cold water tap to the water heater and open all taps where hot water can be drained for de- aerat ...

  • A.O. Smith EQB 200 G - page 23

    23 and tilted slightly in the direction of the drain tap. 3.1.5 Maintenance The inlet combination has to be tested regularly by relieving it (via the relief button). The water has to flow out in a forceful jet. Check whether the discharge pipe is open. We recommend a service agreement on an annual basis. To be able to order spare parts it is import ...

  • A.O. Smith EQB 200 G - page 24

    Fault Possible cause Corrective action 3.2 Fault finding Blocked pilot burner Blocked chimney Safety thermostat Thermocouple defective Thermocouple makes no contact Gas supply closed The thermostat is not connected to the thermocouple Temperature is set too low Control knob in position ( ✸ ) (pilot burns ) Control knob in position ( l ) Flue safe ...

  • A.O. Smith EQB 200 G - page 25

    Fault Possible cause Corrective action Insufficient hot water, or none at all Water leakage Set the temperature regulator at a lower temperature and reignite the pilot burner. Reduce the consumption of hot water. Allow the appliance time to heat the water. Turn the control button to the ( l ) position. Close the gas tap and inform your installer. S ...

  • A.O. Smith EQB 200 G - page 26

    26 4. GUARANTEE The following conditions form the guarantee agreement between A.O. Smith Water Products Company (the warrantor) and the owner of the water heater. 4.1 Guarantee in general If within one year of the original installation date of the water heater any part or component other than the tank shall prove upon examination by the warrantor o ...

  • A.O. Smith EQB 200 G - page 27

    27 any other dealer or stockist of the warrantors products. 4.7 No other guarantee or warranty either expressed or implied is made on behalf of A.O. Smith Water Products Company. With respect to the water heater in question further A.O. Smith does not guarantee this water heater as suitable for purpose except within the terms of warranty detailed a ...

  • A.O. Smith EQB 200 G - page 28

    28 MODEL: ......................................................................................................................... SERIAL NUMBER: ......................................................................................................... ORIGINAL DATE OF INSTALLATION: .................................................................. ...

  • A.O. Smith EQB 200 G - page 29

    29 ...

  • A.O. Smith EQB 200 G - page 30

    30 ...

  • A.O. Smith EQB 200 G - page 31

    31 ...

  • A.O. Smith EQB 200 G - page 32

    32 0307 630 R1 ...

メーカー A.O. Smith カテゴリー Water Heater

A.O. Smith EQB 200 Gのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- EQB 200 Gの取扱説明書
- A.O. Smithの製品カード
- パンフレット
- またはA.O. Smith EQB 200 Gの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、A.O. Smith EQB 200 Gの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、A.O. Smith EQB 200 Gの取り付け説明書、サービスマニュアル、簡易説明書、またはA.O. Smith EQB 200 Gのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、A.O. Smith EQB 200 Gの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

A.O. Smith EQB 200 Gデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがA.O. Smith EQB 200 Gを使用するのを助ける技術的文書のことです。説明書は通常、全てのA.O. Smith EQB 200 Gユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

A.O. Smithの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. A.O. Smith EQB 200 Gの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははA.O. Smith EQB 200 Gの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。A.O. Smith EQB 200 Gに関してこのドキュメントで見つけることができる全てのヒントの目次
3. A.O. Smith EQB 200 Gデバイスの基本機能を使うにあたってのヒント。 A.O. Smith EQB 200 Gのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。A.O. Smith EQB 200 Gに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるA.O. Smith EQB 200 Gのメーカー/サービスへの連絡先に関する情報。

A.O. Smith EQB 200 Gについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもA.O. Smith EQB 200 Gの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがA.O. Smith EQB 200 Gで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)