Anetsberger Brothers 14VFSの取扱説明書

20ページ 0.18 mb
ダウンロード

ページに移動 of 20

Summary
  • Anetsberger Brothers 14VFS - page 1

    1 .4 ;-4 Models 14VF 14VFS Anetsber ger Br others, Inc. 180 North Anets Drive • Northbrook, Illinois 60062 • 847-272-0770 • Fax 847-272-1943 For ANETS Factory W arranty Service • 800-837-2638 Installation, User Operation, & Maintenance Manual Keep this Manual in a Convenient Location for Reference FOR YOUR SAFETY DO NOT store or use gas ...

  • Anetsberger Brothers 14VFS - page 2

    2 CONTENTS Shipping Container Inspection ....................................................... 3 Fryer Gas Supply Specifications .................................................... 3 Fryer Electrical Specifications ....................................................... 4 Figure 1 - Fryer W iring Diagram ......................................... ...

  • Anetsberger Brothers 14VFS - page 3

    3 FR YER GAS SUPPL Y SPECIFICA TIONS Please mak e sur e that your desir ed fr yer loca tion has gas supply factors that are suitable for this product: Gas Supply Inlet Pipe must be ½ “ standard gas line. The gas supply inlet line should be as straight as possible (fewest bends or elbows) to obtain the highest available gas pressure at the fryer ...

  • Anetsberger Brothers 14VFS - page 4

    4 IMPOR T ANT : Read the Code Requir ements and ALL installation instructions car efully , befor e starting the installation. Contact the fac- tory (800/ 837-2638) if any pr oblems or ques- tions arise. The fryer installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 (latest editio ...

  • Anetsberger Brothers 14VFS - page 5

    5 ! Figure 2. F r yer Model 14VF/14VFS Site Installation Requirements CODE REQUIREMENTS (Continued) e. Install this fryer on a non-combustible floor with its back and sides at least 6 ” away from any combustible wall, as shown in Figure 2. WARNING Install this fryer under a ventilation hood that conducts combustion pro- ducts outside the building ...

  • Anetsberger Brothers 14VFS - page 6

    6 WARNING Fryers MUST have a movement- limiting (r estraining cable) device installed to pr event tipping that causes splashing or spilling its HOT contents. NOTE: This movement-limiting de- vice is to be furnished and in- stalled by the fr yer ’ s installing contractor before the fryer is con- nected to the gas line at its desired location. 1 . ...

  • Anetsberger Brothers 14VFS - page 7

    7 INST ALLA TION REQUIREMENTS (Continued) Figure 3. Typical Leg Installation LEG LEVELING INSTRUCTIONS 1. Move the fryer to its desired location. WARNING The fryer MUST NOT tip, rock or wob- ble, to avoid splashing or spilling its HOT shortening contents during operation. 2. T urn the screw-type leg adjustment ends as necessary to level the fryer , ...

  • Anetsberger Brothers 14VFS - page 8

    8 CASTER LEVELING INSTRUC- TIONS 1. Move the fryer to its desired location. 2. Determine whether the fryer tends to wobble or rock when in its desired location. If it does , perform steps 3 through 9. If it does not, skip to step 10, then proceed to the Installation Instructions. WARNING The fryer MUST NOT tip, rock or wob- ble, to avoid splashing ...

  • Anetsberger Brothers 14VFS - page 9

    9 GAS CONNECTION INSTRUCTIONS Installing your ANETS Fryer requires the fol- lowing procedure, after its legs or casters are pro- perly attached and it is in its desired location. 1. Ensure that the gas safety valve control knob in the fryer has its OFF position next to the valvemark. 2 . Ensure that the gas supply inlet line valve is closed (crossw ...

  • Anetsberger Brothers 14VFS - page 10

    10 Please observe the following recommendations to obtain the optimum results from your ANETS Fryer . D ANGER A void moving the fryer while it contains HOT shortening. Drain the shortening from the fryer before moving it for service, clean- ing or maintenance to avoid spilling or splashing. Burns from hot shortening can cause serious injury or deat ...

  • Anetsberger Brothers 14VFS - page 11

    11 Before using the newly installed fryer for food pre- paration, clean the rust preventive material from the kettle: 1 . Thoroughly wipe the interior of the kettle with clean cloths. Open the front door on the lower portion of the fryer to access the drain ball valve. Open the drain ball valve (by aligning the valve handle with the drain ball valv ...

  • Anetsberger Brothers 14VFS - page 12

    12 SHUTDOWN PROCEDURE NOTE: Shutdown is r ecommended at the end of a workday or whenever no frying is scheduled for a period of several hours. T o prevent damage, the fryer MUST also be shutdown whenever there is no shortening in the kettle. 1. T urn the thermostat knob to OFF . 2. T urn the gas control valve knob to align the PILOT setting with th ...

  • Anetsberger Brothers 14VFS - page 13

    13 FR YER OPERA TING INSTR UCTIONS (Continued) Load the fryer basket with the food pr oduct while the basket is not in the hot liquid shortening. DO NOT overload the fryer basket. Load only a pr emeasur ed quantity of food pr oduct ( 1½ lb , typically; less, if smaller portions ar e desir ed). Place the loaded fryer basket into the hot liquid shor ...

  • Anetsberger Brothers 14VFS - page 14

    14 DAIL Y CLEANING PROCEDURE NOTE: Cleaning is recommended at the end of a workday to prepare the fryer for proper operation the next time it is to be used. D ANGER A void moving the fryer while it contains HOT shortening. Drain the shortening from the fryer before moving it for service, clean- ing or maintenance to avoid spilling or splashing. [Re ...

  • Anetsberger Brothers 14VFS - page 15

    15 NOTE: Regular maintenance is recommended to keep the fryer operating properly . Once each month, before beginning fryer opera- tion, check the flue (behind the backsplash panel) to ensure that it is clear and free of obstructions, enabling exhaust combustion gases to flow freely toward the ventilation hood area. DO NOT allow the flue to become e ...

  • Anetsberger Brothers 14VFS - page 16

    16 FR YER TROUBLESHOO TING GUIDE Pilot flame does not stay lighted. 1. Dirty/sooty pilot burner . 2. Low gas supply pressure [less than 6 ” W .C. for natural gas (11 ” W .C. for pro- pane) when all other gas-powered equip- ment is operating.]. 3. Pilot flame too small to heat thermo pile. 4. Pilot flame ‘wavering’ (being blown about by a dr ...

  • Anetsberger Brothers 14VFS - page 17

    17 FR YER TR OUBLESHOO TING GUIDE (Continued) Pilot flame goes out repeatedly . 1. Low gas supply pressure [less than 6 ” W .C. for natural gas (11 ” W .C. for pro- pane) when all other gas-powered equip- ment is operating.]. 2. Loose thermocouple or high-limit thermo- stat connection(s) on gas control valve. 3. Pilot flame does not continuousl ...

  • Anetsberger Brothers 14VFS - page 18

    18 Liquid shortening does not reach the desired temperature for frying. 1. Low gas supply pressure [less than 6 ” W .C. for natural gas (1 1 ” W .C. for propane) when all other gas-powered equipment is operating], causing reduced heat from main burners. 2. Low gas manifold pressure [less than 3½ ” W .C . for natural gas (10 ” W .C. for pro ...

  • Anetsberger Brothers 14VFS - page 19

    19 NOTE: A Parts List for each ANETS Fryer is among the items shipped with each fryer. If an additional copy of this list is needed, please contact the factory as directed on the back cover . FR YER TR OUBLESHOO TING GUIDE (Continued) PROBLEM CA USE REMED Y Liquid shortening does not reach the desired temperature for frying. (Continued) 3. Loose kn ...

  • Anetsberger Brothers 14VFS - page 20

    20 Keep this Manual in a Convenient Location for Reference Anetsber ger Br others, Inc. 180 North Anets Drive • Northbrook, Illinois 60062 • 847-272-0770 • Fax 847-272-1943 T oll-free Customer & W arranty Service: 800/ 837-2638 Form: I-301 Rev . 10/01 Price: $20.00 US LIMITED W ARRANTY ANETSBERGER BROTHERS, INC., Northbrook, Illinois, USA ...

メーカー Anetsberger Brothers カテゴリー Fryer

Anetsberger Brothers 14VFSのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 14VFSの取扱説明書
- Anetsberger Brothersの製品カード
- パンフレット
- またはAnetsberger Brothers 14VFSの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Anetsberger Brothers 14VFSの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Anetsberger Brothers 14VFSの取り付け説明書、サービスマニュアル、簡易説明書、またはAnetsberger Brothers 14VFSのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Anetsberger Brothers 14VFSの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Anetsberger Brothers 14VFSデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがAnetsberger Brothers 14VFSを使用するのを助ける技術的文書のことです。説明書は通常、全てのAnetsberger Brothers 14VFSユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Anetsberger Brothersの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Anetsberger Brothers 14VFSの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははAnetsberger Brothers 14VFSの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Anetsberger Brothers 14VFSに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Anetsberger Brothers 14VFSデバイスの基本機能を使うにあたってのヒント。 Anetsberger Brothers 14VFSのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Anetsberger Brothers 14VFSに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるAnetsberger Brothers 14VFSのメーカー/サービスへの連絡先に関する情報。

Anetsberger Brothers 14VFSについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもAnetsberger Brothers 14VFSの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがAnetsberger Brothers 14VFSで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)