  • Graco 215963 - page 1

    Instructions – Parts List Fast-Flo R Air Motor 12.5 bar (1.25 MPa, 180 psi) Maximum Air Working Pressure Model 215963, Series A 101.6 mm (4 in.) stroke NOTE: T o replace Air Motor 215963, order Motor Replacement Kit 223099. See manual 307977 for parts. 307456U Model 215963 Shown 03652B Important Safety instructions Read all warnings and instructi ...

  • Graco 215963 - page 2

    307456 2 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T roubleshooting 6 . . . . . . . . . . . . . . . . . . . . ...

  • Graco 215963 - page 3

    307456 3 W ARNING SKIN INJECTION HAZARD Spray from the gun, leaks, or ruptured components can inject fluid into your body and cause extremely serious injury , including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury . D Fluid injected into the skin might look like just a cut, but it is a serious inj ...

  • Graco 215963 - page 4

    307456 4 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames, or sparks can cause a hazardous condition and result in a fire or explosion and serious injury . D Ground the equipment and the object being sprayed/dispensed. Refer to Grounding on page 5. D If there is any static sparking or you feel an electric shock w ...

  • Graco 215963 - page 5

    307456 5 Installation Grounding Proper grounding is an essential part of maintaining a safe system. T o reduce the risk of static sparking, ground the pump. Check your local electrical code for detailed grounding instructions for your area and type of equipment. Be sure to ground all of this equipment: D Pump: Use a ground wire and clamp as shown i ...

  • Graco 215963 - page 6

    307456 6 T roubleshooting W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 5. Relieve the Pressure before you check or service any system equipment. NOTE: Check all other possible problems and solu- tions before disassembling the pump. Problem Solutio ...

  • Graco 215963 - page 7

    307456 7 Service NOTE: Repair Kit 214584 is available. For best results, use all the new parts in the kit, even if the old parts look good. Parts included in the kit are marked with a dagger , for example (6†), in the text and illustrations. Air Piston and Lower Spring Service W ARNING T o reduce the risk of injury from trapped air pres- sure whe ...

  • Graco 215963 - page 8

    307456 8 Service 03654 Piston Detail Use pliers (B) only when removing piston. Do not use when tightening piston to rod (23). 220168 Air V alve and Piston Assembly (1 1) Piston Rod and Base 1 2 Apply Sealant T orque to 1.3–1.6 N S m (10–14 in-lb) *16 *14 27 *13 28 15 *12 1 8 23a 23 20 †9 22 26 7 5 6† 8 B 16* 2 4 C 23 0.8 mm (0.032 in.) Min. ...

  • Graco 215963 - page 9

    307456 9 Parts 03655B *16 *14 27 *13 28 15 *12 7 5 †6 8 6† 4 20 23 9† 22 1 26 1 2 1 2 Apply Sealant T orque to 1.3–1.6 N S m (10–14 in-lb) 10† 2 3 Ref No. Part No. Descri ption Qty . Ref No. Part No. Description Qty . 1 1 16343 SCREW , grounding, for non–listed pumps 1 2 104029 LUG, grounding, for UL–listed pumps 1 3 104582 W ASHER, ...

  • Graco 215963 - page 10

    307456 10 Dimensions Mounting Hole Layout 03652B 201 mm (7.9 in.) 1/4–18 npt(f) 59 mm (2.32 in.) diameter 32 mm (1.26 in.) 16 mm (0.63 in.) 27.71 mm (1.09 in.) 8.50 mm (0.33 in.) Diameter ...

  • Graco 215963 - page 11

    307456 1 1 T echnical Data Maximum inbound air pressure 12.5 bar (1.25 MPa,180 psi) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air inlet size 1/4 npt (f) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Graco 215963 - page 12

    307456 12 The Graco Standard W arranty Graco w arrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco w ill, for a period of twelve months fro ...

メーカー Graco カテゴリー Pet Fence

Graco 215963のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- 215963の取扱説明書
- Gracoの製品カード
- パンフレット
- またはGraco 215963の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Graco 215963の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Graco 215963の取り付け説明書、サービスマニュアル、簡易説明書、またはGraco 215963のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Graco 215963の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Graco 215963デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがGraco 215963を使用するのを助ける技術的文書のことです。説明書は通常、全てのGraco 215963ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Gracoの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Graco 215963の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははGraco 215963の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Graco 215963に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Graco 215963デバイスの基本機能を使うにあたってのヒント。 Graco 215963のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Graco 215963に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるGraco 215963のメーカー/サービスへの連絡先に関する情報。

Graco 215963についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもGraco 215963の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがGraco 215963で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)