Hisense Group KFR-3208GWの取扱説明書

26ページ 0.9 mb
ダウンロード

ページに移動 of 26

Summary
  • Hisense Group KFR-3208GW - page 1

    Hisense Corporation INST ALLA TION INST ALLA TION INSTR UCTION INSTR UCTION MANU AL MANU AL SPLIT TYPE AIR CONDITIONER SPLIT TYPE AIR CONDITIONER KFR-3208GW/AE KFR-3208GW/AE ...

  • Hisense Group KFR-3208GW - page 2

    Compact Size This model is smaller than its predecessors and yet offers the same capabilities. Microprocessor Controlled Operation The interior compartment of the remote control unit contains several features to facilitate automatic operation, clearly displayed for easy use. Simple One-touch Wireless Remote Control The remote control unit has sever ...

  • Hisense Group KFR-3208GW - page 3

    Contents 1 Page Alert symbol Caution statements Composition of the air conditioner Operation guide Care and cleaning Tips for energy saving Troubleshooting Schematic diagram Pardon not to inform you if the contents of the manual changes. 1 2 3 8 15 17 17 18 19 W ARNING CAUTION Alert Symbols The symbol refers to a hazard or an unsafe practice which ...

  • Hisense Group KFR-3208GW - page 4

    Caution Statements WARNING WARNING WARNING CAUTION 2 1.Do not turn the air conditioner on and off from the power mains switch. Use the ON/OFF operation button. 2.Do not stick anything into the air outlet of the outdoor unit. This is dangerous because the fan is rotating at high speed. 3.Do not let the children play with the air conditioner. 4.Do no ...

  • Hisense Group KFR-3208GW - page 5

    Refrigerant tubes OUTDOOR UNIT Air outlet Composition of the Air Conditioner 3 1.Diagram of Structure This air conditioner consists of an indoor unit and an outdoor unit. Y ou can control the air conditioner with the remote control unit. NOTE Air Intake Air Outlet Remote Control Unit Refrigerant Tubes Outdoor(Condensing)Unit Drain Hose Air from the ...

  • Hisense Group KFR-3208GW - page 6

    4 2.Introduction of the Indoor ControI Unit INDOOR UNIT OPERATING lamp TIMER lamp POWER lamp POWER TIMER OPERATING HIGH POWER lamp REMOTE CONTROL receiver ON/OFF button IMPORTANT : Avoid using radio equipment such as mobile phone near (within 1m) the indoor unit. Some radio equipment may cause maIfunction of the unit. If the troubIe happens, dis- c ...

  • Hisense Group KFR-3208GW - page 7

    Symbols 3.Introduction of Display (1) Operation mode AUTO COOL HEAT MILD DRY FAN (2) Fan speed Automatic operation HIGH MEDIUM LOW (4) Timer 12-hour ON Timer 12-hour OFF Timer 1-hour OFF Timer (5) NIGHT SETBACK (6) Confirmation of transmission (7) Flap angle indication (8) Sweep indication (9) Indoor unit sensor A A (3) Set temperature 16-30 When s ...

  • Hisense Group KFR-3208GW - page 8

    4.Introduction of the Remote control Unit NOTE The illustration above pictures the remote control unit after the cover has been lowered and removed. When you press the buttons on the remote control unit,the mark appears in the display to transmit the setting changes to the receiver in the air conditioner. A temperature sensor inside the remote cont ...

  • Hisense Group KFR-3208GW - page 9

    :The air conditioner starts at the set time. The air conditioner stops at the set time. or :The air conditioner makes the room warm. :The air conditioner reduces the humidity in the room. direction to one of the six possible positions manually, or to select the The airflow direction can be set manually.(six positions) :The flap moves up and down au ...

  • Hisense Group KFR-3208GW - page 10

    Operation Guide 1. Slide the cover in the direction indicated by the arrow and remove it. 2. Install two AAA alkaline batteries. Make sure the batteries point in the direction m arked in the battery compartment. 3. Use a thin object such as the tip of a pen to press the ACL button. ! NOTE When using the remote control unit, always point the unit&ap ...

  • Hisense Group KFR-3208GW - page 11

    Operation with the Remote Control Unit(continued) NOTE Check that the circuit breaker on the power panel is turned on and that the operation selector of the indoor unit is in the ON position. If the automatic operation settings of the unit do not meet your needs, press the setting buttons as described below and change the settings as desired. STEP ...

  • Hisense Group KFR-3208GW - page 12

    Adjusting the Airflow Direction The horizontal airflow can be adjusted by moving the vertical vanes with your hands to the left or right. 2. Vertical 1. Horizontal ! CAUTION When the humidity is high, the vertical vanes should be in the front position during the cooling or dehumidifying operation. If the vertical vanes are positioned all of the way ...

  • Hisense Group KFR-3208GW - page 13

    Night Setback / Simultaneous Use Energy Saving ¡ñ Night Setback Mode Night Setback Mode is used for saving energy. Press the SLEEP button in operation. The mark appears in the display. T o release the night setback function, press the SLEEPbutton again. NOTE This function loses in automation or airflow mode. 11 TEMP SET TEMP SET C A A 1 HR TEMP F ...

  • Hisense Group KFR-3208GW - page 14

    Using the 12-Hour ON and OFF Timer After the length of time set for TIMER ON elapses, the unit begins operating. The display depicted at left indicates that the air conditioner will begin operating in three hours. Setting Procedures: STEP 1 Press the MODE button and set the desired operation mode and press the ON/OFF operation button. STEP 2 Press ...

  • Hisense Group KFR-3208GW - page 15

    Using the 1-Hour OFF Timer 13 This function causes the unit to operate for one hour and then stop, regardless of whether the unit is on or off when this button is pressed. The indicator in the display indicates that this function is operating. Setting procedure: Regardless of whether the unit is operating or stopped, press the 1 HR .TIMER button. A ...

  • Hisense Group KFR-3208GW - page 16

    14 Special Remarks Heating ( ) Operation Heating performance Defrosting POWER lamp Because this air conditioner heats a room by drawing on the heat of the outside air (heat pump system), the heating efficiency will fall off when the outdoor temperature is very low. If sufficient heat cannot be obtained with this air conditioner , use another heatin ...

  • Hisense Group KFR-3208GW - page 17

    Operation without the Remote Control Unit Care and Cleaning NOTE If you have lost the remote control unit or it has trouble, follow the steps below. 1.When the air conditioner is not running If you want to turn on the air conditioner, pressing the ON/OFF button once. 2.When the air conditioner is running If you want to turn off the air conditioner ...

  • Hisense Group KFR-3208GW - page 18

    Care and Cleaning (continued) Anti-Mold Filter How to remove the anti-mold filter The anti-mode filter behind the air intake grille should be checked and cleaned at least once every three weeks. 1.Grasp both ends of the air intake grille and pull it out and up. 2.Push the anti-mold filter up slightly, and then pull it down. Anti-Mold Filter Cleanin ...

  • Hisense Group KFR-3208GW - page 19

    Tips for Energy Saving Do not Block the air intake and outlet of the unit. If they are obstructed, the unit will not work well, and may be damaged. Let sunlight directly into the room. Use sunshades, blinds or curtains. If the walls and ceiling of the room are warmed by the sun, it will take longer time to cool the room. Do Always try to keep the a ...

  • Hisense Group KFR-3208GW - page 20

    Schematic Diagram 1. Refrigerant Flow Diagram 18 Indoor unit Heat exchanger Heat exchanger Wide tube Narrow tube Outdoor unit Wide service valve Accumulator Compressor 4-way valve Capillary Narrow service tube Cooling cycle Heating cycle Capillary Check valve 2. Permitted ambient temperature for the air conditioner is following:-7 ~+43 . 3. Electri ...

  • Hisense Group KFR-3208GW - page 21

    Appendix: Installation This operation manual has explicit information for installation and maintenance in most conditions. Contact the local distributor or after-sales service for further information. A. Wiring Only qualified professionals should carry out wiring of the appliance. Disconnect the power supply before completion of wiring, piping or c ...

  • Hisense Group KFR-3208GW - page 22

    2. Location 8 2-1 Indoor unit 2-2 Outdoor unit WARNING: Maintain the required space around the appliance to prevent overheat. The area for installation of the appliance should not be in an area with the following: Di rect sunlight H eat resource Inflammable gas Thick oil fog The appliance should be installed in an area, Where the inside space can b ...

  • Hisense Group KFR-3208GW - page 23

    3. Installation of the indoor unit 21 Appendix: Installation Remove the wall plate (1)Remove the fixing screws and keep them for future use (not used during installation). (2)Press the two triangular signs on the outer shell and remove the fixing clip. (3)Remove the wall plate. Mount the wall plate (1)Determine the correct position of the plate wit ...

  • Hisense Group KFR-3208GW - page 24

    22 Appendix: Installation (3)Any part of the drainpipe should be below the outlet of the indoor unit and the joints should be wrapped with waterproof adhesive tape to prevent leakage of condensed water. (4)Bind the tubes, wires and the drainpipe tightly with binding tape, with the drainpipe under the wires. (5)Press down the clamping plate of the t ...

  • Hisense Group KFR-3208GW - page 25

    CAUTION 23 Appendix: Installation 5.Air purging Air and moisture remaining in the refrigerant system have undesirable effects as indicated below. Therefore, they must be purged completely. pressure in the system rises operating current rises cooling efficiency drops moisture in the air may freeze and block capillary tubing water may lead to corrosi ...

  • Hisense Group KFR-3208GW - page 26

    P ACKING LIST NO. NAME AMOUNT 1. 2. 3. 4. 5. 6. 7. 8. 9. OUTDOOR UNIT POWER CABLE DRAINAGE ELBOW * AIR FRESH FIL TER INDOOR UNIT MANUAL REMOTE CONTROL UNIT BA TTERY NAIL SPECIAL 1 1 1 1 1 1 1 2 6 THE SYMBOL "*" ST ANDS FOR THE P ART TO BE PICKED AND MADE PURCHASE. ...

メーカー Hisense Group カテゴリー Air Conditioner

Hisense Group KFR-3208GWのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- KFR-3208GWの取扱説明書
- Hisense Groupの製品カード
- パンフレット
- またはHisense Group KFR-3208GWの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Hisense Group KFR-3208GWの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Hisense Group KFR-3208GWの取り付け説明書、サービスマニュアル、簡易説明書、またはHisense Group KFR-3208GWのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Hisense Group KFR-3208GWの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Hisense Group KFR-3208GWデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがHisense Group KFR-3208GWを使用するのを助ける技術的文書のことです。説明書は通常、全てのHisense Group KFR-3208GWユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Hisense Groupの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Hisense Group KFR-3208GWの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははHisense Group KFR-3208GWの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Hisense Group KFR-3208GWに関してこのドキュメントで見つけることができる全てのヒントの目次
3. Hisense Group KFR-3208GWデバイスの基本機能を使うにあたってのヒント。 Hisense Group KFR-3208GWのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Hisense Group KFR-3208GWに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるHisense Group KFR-3208GWのメーカー/サービスへの連絡先に関する情報。

Hisense Group KFR-3208GWについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもHisense Group KFR-3208GWの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがHisense Group KFR-3208GWで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください