    72 74 70 C OOL H EAT AUTO Mo I2:00 Heat P ump & Heat Cool Meets California T itle 24 Residential Dual Setpoint 5+2 Day Programmable 4 T ime periods V ery Easy to Program Easy T o Read Display Thermoglow Backlight No Batteries Required Auto Changeover No Batteries Required Locking Keypad MODEL TST A TBBPB501 PROGRAMMABLE DIGIT AL THERMOST A T NO ...

  • Bryant TSTATBBPB501 - page 2

    Ta ble Of Content s FRONT P ANEL DISPLAY QUICK STA RT Set the clock and go BASIC OPERA TION PROGRAMMING 4 Time Periods ADV ANCED SETUP ABOUT ADV ANCED OPERA TION W ARRANTY P age 1 CAUTION Follow Installation Instructions before proceeding . SET THERMOST AT T O MODE “ OFF” PRIOR TO CHANGING SETTINGS IN SETUP OR REST ORING F ACTORY DEF AUL TS. TS ...

  • Bryant TSTATBBPB501 - page 3

    72 74 70 C OOL H EAT AUTO Mo I2:00 Front Panel P age 2 Liquid Cryst al Display with Thermoglow Up/Down Buttons Mode Button Fan Button Heat or Cool Indicator Heat = Red, Cool = Green 1 2 3 4 5 2 3 4 5 1 ...

  • Bryant TSTATBBPB501 - page 4

    1 2 4 3 Mode Indicators Selects the operation mode of the equipment. HEA T - indicates the heat mode. COOL - indicates the air conditioning mode. AUTO - indicates the system will automatically changeover between heat and cool modes as the temperature varies. OFF - indicates the entire system is turned off. PROGRAM ON - indicates the stored program ...

  • Bryant TSTATBBPB501 - page 5

    5 6 7 8 Morning, Day , Evening & Night Indication Indicates the program time period. Page 8-1 1. Setup Indication Indicates the thermostat is in the programming mode. Page 12. Fan Operation Indication Fan On - indicates constant, continuous fan operation. When Fan On is not lit - indicates the fan will only operate when necessary to heat or to ...

  • Bryant TSTATBBPB501 - page 6

    During Setup & Programming: Pressing the Mode button selects different flashing items. (Represented in dark black ) Pressing the Up and Down buttons will modify the flashing selection. Press the Mode button. While holding the Mode, press the Fan button for 2 seconds to enter Setup screens. Press both Mode and Fan buttons as above to return to n ...

  • Bryant TSTATBBPB501 - page 7

    The HEA T setting indicates the temperature the r oom has to reach befor e the furnace will turn on to heat the room. The COOL setting indicates the temperature the r oom has to reach befor e the air conditioner will turn on to cool the room. OFF indicates both heating and air conditioning systems are turned off . AUTO will automatically select hea ...

  • Bryant TSTATBBPB501 - page 8

    buttons. In any mode, adjust the desired Set T emperature with Pressing the up/down buttons in Auto mode will adjust both the heat and cool set temperatures simultaneously . Pressing the up/down buttons in Heat or Cool modes will adjust only the heat or cool set temperature. Select Desired T emperature P age 7 Basic Operation 70 72 69 Pm C OOL H EA ...

  • Bryant TSTATBBPB501 - page 9

    Programming 4 T ime periods P age 8 Press Press Press Press Press the Mode button. While holding the Mode, press the Up button for 2 seconds to enter time period programming. Continued Select the Day of the Week. MoTuW eThFr or SaSu. (Weekday or Weekend schedule) Adjust the start time for Morning. Adjust the heating setpoint for Morning. Adjust the ...

  • Bryant TSTATBBPB501 - page 10

    MODE Programming 4 T ime Periods P age 9 Press Press Press Press Press Continued Adjust the start time for Day . Adjust the cooling setpoint for Day . (35 - 99) Adjust the start time for Evening. Adjust the cooling setpoint for Evening. (35 - 99) Adjust the heating setpoint for Day . (35 - 99) MODE MODE MODE MODE Day Am MoTuWeThFr I0:30 Day Am MoTu ...

  • Bryant TSTATBBPB501 - page 11

    Programming 4 T ime Periods P age 10 Press Press Press Press Continued Adjust the start time for Night. Adjust the cooling setpoint for Night. (35 - 99) Adjust the heating setpoint for Evening. (35 - 99) MODE MODE MODE MODE Adjust the heating setpoint for Night. (35 - 99) Evening Pm MoTuWeThFr C OOL H EAT 5:30 75 73 Night Pm MoTuWeThFr I I:30 Night ...

  • Bryant TSTATBBPB501 - page 12

    Programming 4 T ime Periods P age 11 Press MODE Press the Mode button. While holding the Mode, press the Up button for 2 seconds to exit time period programming. MODE T o Exit Programming Su Sa Select the Day of the Week. MoTuW eThFr or SaSu. (Weekday or Weekend schedule) Continue Time Period Programming Morning through Night as done in previous st ...

  • Bryant TSTATBBPB501 - page 13

    Advanced Setup P age 12 Press Press Press Continued Adjust the time of day clock. Select the day of the week. Press the Mode button. While holding the Mode, press the Fan button for 5 seconds to enter Setup screens. NOTE: Each step # is located at the top right corner of the display for easy reference. Tip: T o change hours quickly , press and hold ...

  • Bryant TSTATBBPB501 - page 14

    Advanced Setup P age 13 Press Press Press Press Continued Select the reversing valve polarity for Heat Pump, O or B. (Step 4 only appears if heat pump is on in step 3) Select Electric Heat On or Off. (S tep 5 only appears if heat pump is off in step 3) Adjust the minimum difference between cooling & heating setpoints. Adjust the deadband from 1 ...

  • Bryant TSTATBBPB501 - page 15

    Advanced Setup P age 14 Select the display back- light always On , or Off after 8 seconds. On Off Select thermostat operation in degrees F ahrenheit or C entigrade. C F Press the Mode button. While holding the Mode, press the Fan button for 2 seconds to leave the Setup screens. If no buttons are pressed, the display will leave the setup screens aft ...

  • Bryant TSTATBBPB501 - page 16

    Advanced Setup P age 15 S tep # Description Range Factory Default 1 T ime of day clock set 24 hour 12:00 Am 2 Day of the week Sun - Sat Monday 3 Heat Pump Off / On Off 4 Reversing V alve polarity O / B O 5 Electric Heat Off / On Off 6 Deadband or T emperature swing 1 - 6 2 7 Forced minimum difference heat/cool 0 - 6 2 8 Cycles per hour d, d1, 2 - 6 ...

  • Bryant TSTATBBPB501 - page 17

    About Advanced Features & Operation P age 16 2 ST AGE OPERA TION - The 2nd S tage of heat or cool is turned on when ( 1 ) the 1st S tage has been on for a minimum of two minutes, and ( 2 ) the temperature spread from the setpoint is equal to or greater than: the setpoint plus the deadband, plus 2 degrees. Heat Setpoint Cool Setpoint Dead Band D ...

  • Bryant TSTATBBPB501 - page 18

    About Advanced Features & Operation P age 17 ELECTRIC HEA T - Selecting Electric Heat on, page 13, step 5 , will cause the thermostat to turn on the fan any time there is a heat demand. Since all control the fan, this feature should be off is only electric. immediately gas furnaces unless the heater EMERGENCY HEA T - Is a feature available to H ...

  • Bryant TSTATBBPB501 - page 19

    About Advanced Features & Operation P age 18 KEYP AD LOCK - T o prevent unauthorized use of the thermostat, the front panel buttons may be disabled. T o disable, or ‘lock’ the keypad, press and hold in the Mode button. While holding the Mode button in, press the Up and Down buttons in together . The Locked icon will appear on the display . ...

  • Bryant TSTATBBPB501 - page 20

    About Advanced Features & Operation P age 19 DUAL SETPOINT BEHA VIOR - The adjustable setpoint range is: 35 - 99 degrees in Fahrenheit and 7 - 35 degrees in Centigrade. When in the modes Heat or Cool, this adjustable range is unhampered. When adjusting any Auto mode, including programming Occupied and Unoccupied periods, the 1050 will not allow ...

  • Bryant TSTATBBPB501 - page 21

    P age 20 About Advanced Features & Operation F ACTOR Y DEF AUL TS - If, for any reason it is desirable to return all stored settings back to the factory default settings, press the Mode button. While holding the Mode button in, press the Down button for 2 sec. All icons will appear . Press and hold in the Fan button until Fd appears. This reset ...

  • Bryant TSTATBBPB501 - page 22

    P age 21 P/N 88-347 Rev . 1 W arranty Five- Ye ar Warranty - This Product is warranted to be free from defects in material and workmanship. If defect appears within five years from the date of original installation , whether or not actual use begins on that date, then the product does meet this warranty . A new or remanufactured part , at the manuf ...

メーカー Bryant カテゴリー Thermostat

Bryant TSTATBBPB501のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- TSTATBBPB501の取扱説明書
- Bryantの製品カード
- パンフレット
- またはBryant TSTATBBPB501の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、Bryant TSTATBBPB501の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、Bryant TSTATBBPB501の取り付け説明書、サービスマニュアル、簡易説明書、またはBryant TSTATBBPB501のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、Bryant TSTATBBPB501の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

Bryant TSTATBBPB501デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがBryant TSTATBBPB501を使用するのを助ける技術的文書のことです。説明書は通常、全てのBryant TSTATBBPB501ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Bryantの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. Bryant TSTATBBPB501の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははBryant TSTATBBPB501の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。Bryant TSTATBBPB501に関してこのドキュメントで見つけることができる全てのヒントの目次
3. Bryant TSTATBBPB501デバイスの基本機能を使うにあたってのヒント。 Bryant TSTATBBPB501のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。Bryant TSTATBBPB501に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるBryant TSTATBBPB501のメーカー/サービスへの連絡先に関する情報。

Bryant TSTATBBPB501についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもBryant TSTATBBPB501の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがBryant TSTATBBPB501で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)