    168106-PUM-A-1205 USER’S INFORMA TION, MAINTENANCE AND SER VICE MANU AL HIGH EFFICIENC Y TUBULAR HEA T EX CHANGER SERIES MODELS: GF9/GM9/ G Y9 (Single Stage Downflow/Horizontal) EFFICIENCY RATING CERTIFIED ISO 9001 Certified Quality Management System The manufacturer recommend s that the user read all sec- tions of this manual a nd keep the manua ...

  • York GY9 - page 2

    168106-PUM-A-1205 2 Unitary Products Group 7. NEVER . . .S tore flammable materials of any kind near your fur- nace. Gasoline, solvents, and ot her volatile liquids should be stored only in approved containers outside your home. These materials vaporiz e easily and are extremely dangerous. 8. NEVER . . .S tore cleaning materials near your furnace. ...

  • York GY9 - page 3

    168106-PUM-A-1205 Unitary Products Group 3 HOW Y OUR GAS FURNACE W ORKS Y o ur furnace is a very easy appliance to take for granted. Season after season, it sits there in your home, keeping you warm and comfortable. For this reason, you may neve r have given much thought to the way your furnace operates. In order to get the safest and most ef ficie ...

  • York GY9 - page 4

    168106-PUM-A-1205 4 Unitary Products Group FURNACE USER MAINTENANCE Blower Care Even with good filters properly in pl ace, blower wheels and motors will become dust laden after long months of operation. The entire blower assembly should be inspected annually . If the motor an d wheel are heavily coated with dust, they can be brushed and cleaned wit ...

  • York GY9 - page 5

    168106-PUM-A-1205 Unitary Products Group 5 Motor Lubrication The motors in these furnaces are permanently lubricated, and do not require periodic oiling. SECTION II: SER VICE AND MAINTE NANCE MANU AL SAFETY SECTION The following safety rules must be followed when s ervicing the furnace. FURNACE MAINTENANCE SECTION The furnace should be cleane d and ...

  • York GY9 - page 6

    168106-PUM-A-1205 6 Unitary Products Group Hot Surface Ignition System FURNACE CLEANING SECTION NOTE: The cleaning operations listed below must be p erformed only by a qualified service agency . Burner Removal/Clea ning The main burners should be checked periodically for dirt accumulation. If cleaning is required, follow this procedure: 1. T urn of ...

  • York GY9 - page 7

    168106-PUM-A-1205 Unitary Products Group 7 3 RED FLASHES: This indicates the normally open pressure switch contact did not close after the induc er was energized. This could be caused by a number of problems: faul ty inducer , blocked vent pipe, bro- ken pressure switch hose or faulty p ressure switch. 4 RED FLASHES: This indicates that a prim ary ...

  • York GY9 - page 8

    168106-PUM-A-1205 8 Unitary Products Group SECTION III: REPLACEMENT P ARTS LIST 61 7 13 11 2 27 17 34 29 32 54 5 66 71 70 43 43 9 37 44 26 14 10 31 35 18 74 53 15 16 1 64 56,57 21 20 22 49 42 51 6 41 30 28 5 14 48 25 4 2 46 58 47 50 24 17 71 54 59 60 6 42 10 36 19 65 79 23 14 44 30 9, 37 45 41 6 33 28 40 A A ...

  • York GY9 - page 9

    168106-PUM-A-1205 Unitary Products Group 9 ITEM DESCRIPTION MOTOR 1M O T O R , DIRECT DRIVE BLOWER 2 MOTOR, INDUCER ASS’Y ELECTRICAL 3 CAP ACITOR, RUN (7.5MFD/370V) CAP ACITOR, RUN (10MFD/370V) 4 SWITCH, LIMIT (INDUCER) 5 LIMIT , TEMPERA TURE (Primary) 6 LIMIT , FLAME ROLL-OUT 7 CONTROL, FURNACE MODULE 8* FUSE 9I G N I T E R 10 SENSOR, FLAME 1 1 ...

  • York GY9 - page 10

    168106-PUM-A-1205 10 Unitary Products Group FIELD INST ALLED ACCESSO RIES - NON-ELECTRICAL MODEL NO. DESCRIPTION USED WITH 1NP0347 PROP ANE (LP) CONVERSION KIT ALL MODELS 1CT0302 CONCENTRIC INT AKE/VENT 2” ALL MODELS EXCEPT 120 MBH 1CT0303 CONCENTRIC INT AKE/VENT 3” ALL MODELS 1PS0904 HIGH AL TITUDE PRESSURE SWITCH KIT (Does Not Include Orifice ...

  • York GY9 - page 11

    168106-PUM-A-1205 Unitary Products Group 11 SECTION IV: WIRING DIAGRAM FIGURE 9: Wiring Diagram ...

  • York GY9 - page 12

    Subject to change without notice. Printed in U.S.A. 168106-PUM-A-1205 Copyright © by Unitary Products Group 2005. All rights reserved. Supersedes: 165458-PUM-A-0905 Unitary 5005 Norman Product s Y ork OK Group Drive 73069 ...

メーカー York カテゴリー Marine Heating System

York GY9のメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- GY9の取扱説明書
- Yorkの製品カード
- パンフレット
- またはYork GY9の消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、York GY9の取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、York GY9の取り付け説明書、サービスマニュアル、簡易説明書、またはYork GY9のユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、York GY9の製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

York GY9デバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがYork GY9を使用するのを助ける技術的文書のことです。説明書は通常、全てのYork GY9ユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

Yorkの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. York GY9の説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははYork GY9の目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。York GY9に関してこのドキュメントで見つけることができる全てのヒントの目次
3. York GY9デバイスの基本機能を使うにあたってのヒント。 York GY9のユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。York GY9に関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるYork GY9のメーカー/サービスへの連絡先に関する情報。

York GY9についてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもYork GY9の問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがYork GY9で同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)