Gardena Comfort Pump 8500 - page 1
D GB F NL S DK FIN N I E P PL H CZ SK GR RUS SLO HR SRB BIH UA RO TR BG AL ES T LT LV GA RDE NA ® D Betriebsanleitung T auchpumpe / Schmutzwasserpumpe GB Operating Instructions Submersible Pump / Dirty W ater Pump F Mode d’emploi Pompe d’évacuation pour eaux claires / Pompe d’évacuation pour eaux chargées NL Instructies voor gebruik Dompe ...
-
Gardena Comfort Pump 8500 - page 2
Intended use Liquids to be pumped Please note GARDENA Su bme r si bl e P ump 9000 / 13000 aquasensor / Di rty W ate r Pu mp 8500 / 13000 aquasensor T ranslation of the original instructions from Ger man. Please read these operating instructions carefully and obser ve the notes giv en. Use the instructions to familiarise yourself with the pump , its ...
-
Gardena Comfort Pump 8500 - page 3
12 GB 2. Safety Instructions Electrical Safety According to DIN VDE (Ger man Electrical Engineers’ Association) 0100, submersible pumps and dir ty water pumps ma y only be used in swimming pools , garden ponds, and fountains if the pump is oper ated via a residual-current de vice with a residual-current rating of ≤ 30 mA. The pump must not be o ...
-
Gardena Comfort Pump 8500 - page 4
13 GB Instructions for submer sible pumps When you pur chase your pump the s wivel feet are set to the flat suction position (1 mm). v For normal operation, turn the feet 1 80 ° to 5 mm. The pump is lifted 5 mm. v Clear the outlet line before use . Thermal protection s witch The pump is automatically switched off on ov erheating by the built-in th ...
-
Gardena Comfort Pump 8500 - page 5
14 GB Automatic operation : 2. Only f or the submersible pumps Art. No. 1783 / 1785 : Inser t the non-return valve z V supplied into the universal connector 2 with the word UP pointing upwards . 3. Screw the univ ersal fitting 2 onto the pump . 4. Connect the hose to the univ ersal fitting 2 . We recommend 38 mm (1 ¹⁄₂ " ) 25 mm (1 " ...
-
Gardena Comfort Pump 8500 - page 6
15 GB Manual operation : Only f or the submersible pumps : Flat suction / Normal operation The pump remains in operation continuously . The ON sensor 3 is lock ed in manual position and bridged via the contact 7 . 1. Push OFF sensor 4 and ON sensor 3 right down so that the ON sensor 3 touches the contact 7 . 2. Stand the pump on a firm surface – ...
-
Gardena Comfort Pump 8500 - page 7
16 GB Flushing the Pump : Clean sensors : Cleaning the suction base and impeller : 6. Maintenance The pumps are vir tually maintenance-free. After having pumped chlorinated s wimming pool water or other liquids leaving residues , the pump should be r insed with clear wate r. The sensors will only w ork reliably if the y are cleaned regu- larly (at ...
-
Gardena Comfort Pump 8500 - page 8
17 GB Problem Probable cause Remedy Pump is running, When star ting the pump , v Submerge pump deeper. but doesn’t deliver water height falls belo w the min. water lev el. The pump does not switch Sensors 3 / 4 and contacts 7 v Clean sensors (see on or off. Pump switches off are dir ty . 6. Maintenance). although the OFF sensor is in the water Pu ...
-
Gardena Comfort Pump 8500 - page 9
18 GB 9. Ser vice / W arranty GARDENA guarantees this product f or 2 years ( from date of purchase). This guar antee covers all serious def ects of the unit that can be prov ed to be material or manufacturing faults . Under warranty w e will either replace the unit or repair it free of charge if the follo wing conditions apply : • The unit must h ...
-
Gardena Comfort Pump 8500 - page 10
227 7000 Art. 1 783 / 1785 7500 Art. 1 797 / 1799 K ennlinie T auchpumpe P erformance characteristics Submersible Pump Courbe de performance Pompe d’évacuation pour eaux clair es Prestatiegrafiek Dompelpomp Kapacitetskurva Dränkbar pump Ydelses karakteristika Dykpumpe Ominaiskäyrä Uppopumppu Merkingslinje for Lensepumpe Curva di rendimento pe ...
-
Gardena Comfort Pump 8500 - page 11
228 D Produkthaftung Wir weisen ausdrüc klich darauf hin, dass wir nach dem Produkthaftungsgesetz nicht für durch unsere Geräte hervorgerufene Schäden einzustehen haben, sof er n diese durch unsachgemäße Reparatur v er ursacht oder bei einem T eileaustausch nicht unsere Or iginal GARDENA T eile oder von uns freigegebene T eile verw endet werd ...
-
Gardena Comfort Pump 8500 - page 12
230 D EG-Konf ormitätserklärung Der Unterzeichnete Husqvarna AB, 561 82 Huskvarna, Sweden bestätigt, dass die nachfolgend bezeichneten Geräte in der von uns in V erkehr gebrachten Ausführung die Anforderungen der harmonisierten EU-Richtlinien, EU-Sicherheitsstandards und produktspezifischen Standards erfüllen. Bei einer nicht mit uns abgestim ...
-
Gardena Comfort Pump 8500 - page 13
231 Harmonisier te EN : EN ISO 12100 - 1 EN ISO 12100 - 2 EN 60335 - 1 EN 60335 - 2 - 41 Hinterlegte Dokumentation : GARDENA T echnische Dokumentation E. Renn 89079 Ulm Deposited Documentation : GARDENA T echnical Documentation E. Renn 89079 Ulm Documentation déposée : Documentation technique GARDENA E. Renn 89079 Ulm Anbringungsjahr der CE-Kennz ...
-
Gardena Comfort Pump 8500 - page 14
232 Deutschland / Germany GARDENA GmbH Central Service Hans-Lorenser-Straße 40 D - 89079 Ulm Produktfragen: (+ 49) 731 490 - 123 Reparaturen: (+ 49) 731 490 - 290 service @ gardena.com Albania COBAL T Sh.p.k. Rr . Siri K odra 1000 Tirana Argentina Husqvarna Argentina S.A. Av .del Liber tador 5954 - Piso 11 - T orre B (C1428ARP) Buenos Aires Phone ...